This file is indexed.

/usr/share/psychtoolbox-3/PsychCal/CalibrateAmbDrvr.m is in psychtoolbox-3-common 3.0.11.20140816.dfsg1-1.

This file is owned by root:root, with mode 0o644.

The actual contents of the file can be viewed below.

  1
  2
  3
  4
  5
  6
  7
  8
  9
 10
 11
 12
 13
 14
 15
 16
 17
 18
 19
 20
 21
 22
 23
 24
 25
 26
 27
 28
 29
 30
 31
 32
 33
 34
 35
 36
 37
 38
 39
 40
 41
 42
 43
 44
 45
 46
 47
 48
 49
 50
 51
 52
 53
 54
 55
 56
 57
 58
 59
 60
 61
 62
 63
 64
 65
 66
 67
 68
 69
 70
 71
 72
 73
 74
 75
 76
 77
 78
 79
 80
 81
 82
 83
 84
 85
 86
 87
 88
 89
 90
 91
 92
 93
 94
 95
 96
 97
 98
 99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
function cal = CalibrateAmbDrvr(cal,USERPROMPT,whichMeterType,blankOtherScreen)
% cal =  CalibrateAmbDrvr(cal,USERPROMPT,whichMeterType,blankOtherScreen)
%
% This script does the work for monitor ambient calibration.

% 4/4/94		dhb		Wrote it.
% 8/5/94		dhb, ccc	More flexible interface.
% 9/4/94		dhb		Small changes.
% 10/20/94	dhb		Add bgColor variable.
% 12/9/94   ccc   Nine-bit modification
% 1/23/95		dhb		Pulled out working code to be called from elsewhere.
%						dhb		Make user prompting optional.
% 1/24/95		dhb		Get filename right.
% 12/17/96  dhb, jmk  Remove big bug.  Ambient wasn't getting set.
% 4/12/97   dhb   Update for new toolbox.
% 8/21/97		dhb		Don't save files here.
%									Always measure.
% 4/7/99    dhb   NINEBIT -> NBITS
%           dhb   Handle noMeterAvail, RADIUS switches.
% 9/22/99   dhb, mdr  Make boxRect depend on boxSize, defined up one level.
% 12/2/99   dhb   Put background on after white box for aiming.
% 8/14/00   dhb   Call to CMETER('Frequency') only for OS9.
% 8/20/00   dhb   Remove bits arg to SetColor.
% 8/21/00   dhb   Remove RADIUS arg to MeasMonSpd.
% 9/11/00   dhb   Remove syncMode code, any direct refs to CMETER.
% 9/14/00   dhb   Use OpenWindow to open.
%           dhb   Made it a function.
% 7/9/02    dhb   Get rid of OpenWindow, CloseWindow.
% 9/23/02   dhb, jmh  Force background to zero when measurements come on.
% 2/26/03   dhb   Tidy comments.
% 4/1/03    dhb   Fix ambient averaging.
% 8/19/12   dhb   Add codelet suggested by David Jones to clean up at end.  See comment in CalibrateMonSpd.
% 8/19/12   mk    Rewrite setup and clut code to be able to better cope with all
%                 the broken operating systems / drivers / gpus and to also
%                 support DataPixx/ViewPixx devices.

global g_usebitspp;

% If the global flag for using Bits++ is empty, then it hasn't been
% initialized and default it to 0.
if isempty(g_usebitspp)
    g_usebitspp = 0;
end

% Check meter
if ~whichMeterType
	CMCheckInit;
end

% User prompt
if USERPROMPT
	if cal.describe.whichScreen == 0
		fprintf('Hit any key to proceed past this message and display a box.\n');
		fprintf('Focus radiometer on the displayed box.\n');
		fprintf('Once meter is set up, hit any key - you will get %g seconds\n',...
                cal.describe.leaveRoomTime);
		fprintf('to leave room.\n');
        KbStrokeWait(-1);
	else
		fprintf('Focus radiometer on the displayed box.\n');
		fprintf('Once meter is set up, hit any key - you will get %g seconds\n',...
                cal.describe.leaveRoomTime);
		fprintf('to leave room.\n');
	end
end

% Blank other screen, if requested:
if blankOtherScreen
    % We simply open an onscreen window with black background color:
    Screen('OpenWindow', cal.describe.whichBlankScreen, 0);
end

% Setup screen to be measured
% ---------------------------

% Prepare imaging pipeline for Bits+ Bits++ CLUT mode, or DataPixx/ViewPixx
% L48 CLUT mode (which is pretty much the same). If such a special output
% device is used, the Screen('LoadNormalizedGammatable', win, clut, 2);
% command uploads 'clut's into the device at next Screen('Flip'), taking
% care of possible graphics driver bugs and other quirks:
PsychImaging('PrepareConfiguration');

if g_usebitspp == 1
    % Setup for Bits++ CLUT mode. This will automatically load proper
    % identity gamma tables into the graphics hardware and into the Bits+:
    PsychImaging('AddTask', 'General', 'EnableBits++Bits++Output');
end

if g_usebitspp == 2
    % Setup for DataPixx/ViewPixx etc. L48 CLUT mode. This will
    % automatically load proper identity gamma tables into the graphics
    % hardware and into the device:
    PsychImaging('AddTask', 'General', 'EnableDataPixxL48Output');
end

% Open the window:
[window, screenRect] = PsychImaging('OpenWindow', cal.describe.whichScreen);
if (cal.describe.whichScreen == 0)
    HideCursor;
end

theClut = zeros(256,3);
if g_usebitspp
    % Load zero theClut into device:
    Screen('LoadNormalizedGammaTable', window, theClut, 2);
    Screen('Flip', window);    
else
    % Load zero lut into regular graphics card:
    Screen('LoadNormalizedGammaTable', window, theClut);
end

% Draw a box in the center of the screen
boxRect = [0 0 cal.describe.boxSize cal.describe.boxSize];
boxRect = CenterRect(boxRect, screenRect);
theClut(2,:) = [1 1 1];
Screen('FillRect', window, 1, boxRect);
if g_usebitspp
    Screen('LoadNormalizedGammaTable', window, theClut, 2);
    Screen('Flip', window, 0, 1);
else
    Screen('LoadNormalizedGammaTable', window, theClut);
end

% Wait for user
if USERPROMPT == 1
    KbStrokeWait(-1);
	fprintf('Pausing for %d seconds ...', cal.describe.leaveRoomTime);
	WaitSecs(cal.describe.leaveRoomTime);
	fprintf(' done\n');
end

% Put in appropriate background.
theClut(2,:) = cal.bgColor';
if g_usebitspp
    Screen('FillRect', window, 1, boxRect);
    Screen('LoadNormalizedGammaTable', window, theClut, 2);
    Screen('Flip', window, 0, 1);
else
    Screen('LoadNormalizedGammaTable', window, theClut);
end

% Start timing
t0 = clock;

ambient = zeros(cal.describe.S(3), 1);
for a = 1:cal.describe.nAverage
    % Measure ambient
    ambient = ambient + MeasMonSpd(window, [0 0 0]', cal.describe.S, 0, whichMeterType, theClut);
end
ambient = ambient / cal.describe.nAverage;

% Close the screen, restore cluts:
if g_usebitspp
    % Load identity clut on Bits++ / DataPixx et al.:
    BitsPlusPlus('LoadIdentityClut', window);
    Screen('Flip', window);
end

% Restore graphics card gamma tables to original state:
RestoreCluts;

% Show hidden cursor:
if cal.describe.whichScreen == 0
	ShowCursor;
end

% Close all windows:
Screen('CloseAll');

% Report time:
t1 = clock;
fprintf('CalibrateAmbDrvr measurements took %g minutes\n', etime(t1,t0)/60);

% Update structure
Smon = cal.describe.S;
Tmon = WlsToT(Smon);
cal.P_ambient = ambient;
cal.T_ambient = Tmon;
cal.S_ambient = Smon;

% Done:
return;