This file is indexed.

/usr/share/psychtoolbox-3/PsychCal/CalibrateManualDrvr.m is in psychtoolbox-3-common 3.0.11.20140816.dfsg1-1.

This file is owned by root:root, with mode 0o644.

The actual contents of the file can be viewed below.

  1
  2
  3
  4
  5
  6
  7
  8
  9
 10
 11
 12
 13
 14
 15
 16
 17
 18
 19
 20
 21
 22
 23
 24
 25
 26
 27
 28
 29
 30
 31
 32
 33
 34
 35
 36
 37
 38
 39
 40
 41
 42
 43
 44
 45
 46
 47
 48
 49
 50
 51
 52
 53
 54
 55
 56
 57
 58
 59
 60
 61
 62
 63
 64
 65
 66
 67
 68
 69
 70
 71
 72
 73
 74
 75
 76
 77
 78
 79
 80
 81
 82
 83
 84
 85
 86
 87
 88
 89
 90
 91
 92
 93
 94
 95
 96
 97
 98
 99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
% CalibrateManualDrvr
%
% Get some manual measurements from radiometer/photometer.

% 3/8/02  dhb, ly  Wrote it.
% 2/21/03 dhb, ly  Specify input units.

global g_usebitspp;

% If the global flag for using Bits++ is empty, then it hasn't been
% initialized and default it to 0.
if isempty(g_usebitspp)
    g_usebitspp = 0;
end

if USERPROMPT
	if cal.describe.whichScreen == 0
		fprintf('Hit any key to proceed past this message and display a box.\n');
		fprintf('Insert manual photometer/radiometer.\n');
		fprintf('Once meter is set up, hit any key to proceed\n');
		KbStrokeWait(-1);
	else
		fprintf('Insert manual photometer/radiometer.\n');
		fprintf('Once meter is set up, hit any key to proceed\n');
	end
end

% Blank other screen
if blankOtherScreen
    Screen('OpenWindow', cal.describe.whichBlankScreen, 0);
end

% Setup screen to be measured
% ---------------------------

% Prepare imaging pipeline for Bits+ Bits++ CLUT mode, or DataPixx/ViewPixx
% L48 CLUT mode (which is pretty much the same). If such a special output
% device is used, the Screen('LoadNormalizedGammatable', win, clut, 2);
% command uploads 'clut's into the device at next Screen('Flip'), taking
% care of possible graphics driver bugs and other quirks:
PsychImaging('PrepareConfiguration');

if g_usebitspp == 1
    % Setup for Bits++ CLUT mode. This will automatically load proper
    % identity gamma tables into the graphics hardware and into the Bits+:
    PsychImaging('AddTask', 'General', 'EnableBits++Bits++Output');
end

if g_usebitspp == 2
    % Setup for DataPixx/ViewPixx etc. L48 CLUT mode. This will
    % automatically load proper identity gamma tables into the graphics
    % hardware and into the device:
    PsychImaging('AddTask', 'General', 'EnableDataPixxL48Output');
end

% Open the window:
[window, screenRect] = PsychImaging('OpenWindow', cal.describe.whichScreen);
if (cal.describe.whichScreen == 0)
    HideCursor;
end

theClut = zeros(256,3);
if g_usebitspp
    % Load zero theClut into device:
    Screen('LoadNormalizedGammaTable', window, theClut, 2);
    Screen('Flip', window);    
else
    % Load zero lut into regular graphics card:
    Screen('LoadNormalizedGammaTable', window, theClut);
end

% Draw a box in the center of the screen
if ~isfield(cal.describe, 'boxRect')
	boxRect = [0 0 cal.describe.boxSize cal.describe.boxSize];
	boxRect = CenterRect(boxRect,screenRect);
else
	boxRect = cal.describe.boxRect;
end

theClut(2,:) = [1 1 1];
Screen('FillRect', window, 1, boxRect);
if g_usebitspp
    Screen('LoadNormalizedGammaTable', window, theClut, 2);
else
    Screen('LoadNormalizedGammaTable', window, theClut);
end
Screen('Flip', window, 0, 1);

% Wait for user
if USERPROMPT == 1
  KbStrokeWait(-1);
end

% Put correct surround for measurements.
theClut(1,:) = cal.bgColor';
if g_usebitspp
    Screen('FillRect', window, 1, boxRect);
    Screen('LoadNormalizedGammaTable', window, theClut, 2);
    Screen('Flip', window, 0, 1);
else
    Screen('LoadNormalizedGammaTable', window, theClut);
end

% We have put up white:
cal.manual.white = [];
while isempty(cal.manual.white)
	if cal.manual.photometer
		cal.manual.white = input('Enter photometer reading (cd/m2): ');
	else
		cal.manual.white = 1e-6*input('Enter radiometer reading (micro Watts): ');
	end
end

theClut(2,:) = [0 , 0 , 0];
if g_usebitspp
    Screen('LoadNormalizedGammaTable', window, theClut, 2);
    Screen('Flip', window, 0, 1);
else
    Screen('LoadNormalizedGammaTable', window, theClut);
end
cal.manual.black = [];
while isempty(cal.manual.black)
	if cal.manual.photometer
		cal.manual.black = input('Enter photometer reading (cd/m2): ');
	else
		cal.manual.black = 1e-6*input('Enter radiometer reading (micro Watts): ');
	end
end
cal.manual.increment = cal.manual.white - cal.manual.black;

% Close the screen, restore cluts:
if g_usebitspp
    % Load identity clut on Bits++ / DataPixx et al.:
    BitsPlusPlus('LoadIdentityClut', window);
    Screen('Flip', window);
end

% Restore graphics card gamma tables to original state:
RestoreCluts;

% Show hidden cursor:
if cal.describe.whichScreen == 0
	ShowCursor;
end

% Close all windows:
Screen('CloseAll');