This file is indexed.

/usr/lib/nagios/plugins/check_uptime is in nagios-plugins-contrib 14.20141104.

This file is owned by root:root, with mode 0o755.

The actual contents of the file can be viewed below.

  1
  2
  3
  4
  5
  6
  7
  8
  9
 10
 11
 12
 13
 14
 15
 16
 17
 18
 19
 20
 21
 22
 23
 24
 25
 26
 27
 28
 29
 30
 31
 32
 33
 34
 35
 36
 37
 38
 39
 40
 41
 42
 43
 44
 45
 46
 47
 48
 49
 50
 51
 52
 53
 54
 55
 56
 57
 58
 59
 60
 61
 62
 63
 64
 65
 66
 67
 68
 69
 70
 71
 72
 73
 74
 75
 76
 77
 78
 79
 80
 81
 82
 83
 84
 85
 86
 87
 88
 89
 90
 91
 92
 93
 94
 95
 96
 97
 98
 99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
#!/usr/bin/perl -w
#
# ============================== SUMMARY =====================================
#
# Program : check_uptime.pl
# Version : 0.521
# Date    : Oct 4, 2012
# Authors : William Leibzon - william@leibzon.org
# Licence : GPL - summary below, full text at http://www.fsf.org/licenses/gpl.txt
#
# =========================== PROGRAM LICENSE =================================
#
# This program is free software; you can redistribute it and/or modify
# it under the terms of the GNU General Public License as published by
# the Free Software Foundation; either version 2 of the License, or
# (at your option) any later version.
#
# This program is distributed in the hope that it will be useful,
# but WITHOUT ANY WARRANTY; without even the implied warranty of
# MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.  See the
# GNU General Public License for more details.
#
# You should have received a copy of the GNU General Public License
# along with this program; if not, write to the Free Software
# Foundation, Inc., 675 Mass Ave, Cambridge, MA 02139, USA.
#
# ===================== INFORMATION ABOUT THIS PLUGIN =========================
#
#  This plugin returns uptime of the system returning data in text (readable)
#  format as well as in minutes for performance graphing. The plugin can either
#  run on local system unix system (that supports standard 'uptime' command
#  or check remote system by SNMP. The plugin can report one CRITICAL or
#  WARNING alert if system has been rebooted since last check.
#
# ======================  SETUP AND PLUGIN USE NOTES  =========================
#
#  The plugin can either retrieve information from local system (when you
#  run it through check_nrpe for example) or by SNMP from remote system.
#
#  On local system it will execute standard unix 'uptime' and 'uname -a'.
#
#  On a remote system it'll retrieve data from sysSystem for system type
#  and use that to decide if further data should be retrieved from
#    sysUptime (OID 1.3.6.1.2.1.1.3.0) for windows or
#    hostUptime (OID 1.3.6.1.2.1.25.1.1.0) for unix system or
#    snmpEngineTime (OID 1.3.6.1.6.3.10.2.1.3) for cisco switches
#
#  For information on available options please execute it with --help i.e:
#    check_uptime.pl --help
#
#  As I dont have time for extensive documentation below is all very brief:
#
#  1. You can also specify warning and critical thresholds which will
#     give warning or critical alert if system has been up for lees then
#     specified number of minutes. Example:
#        check_uptime.pl -w 5
#     Will give warning alert if system has been up for less then 5 minutes
#
#  2. For performance data results you can use '-f' option which will give
#     total number of minutes the system has been up.
#
#  3. A special case is use of performance to feed data from previous run
#     back into the plugin. This is used to cache results about what type
#     of system it is (you can also directly specify this with -T option)
#     and also means -w and -c threshold values are ignored and instead
#     plugin will issue ONE alert (warning or critical) if system uptime
#     changes from highier value to lower
#
# ============================ EXAMPLES =======================================
#
# 1. Local server (use with NRPE or on nagios host), warning on < 5 minutes:
#
# define command {
#        command_name check_uptime
#        command_line $USER1$/check_uptime.pl -f -w 5
# }
#
# 2. Local server (use with NRPE or on nagios host),
#    one critical alert on reboot:
#
# define command {
#        command_name check_uptime
#        command_line $USER1$/check_uptime.pl -f -c -P "SERVICEPERFDATA$"
# }
#
# 3. Remote server SNMP v2, one warning alert on reboot,
#    autodetect and cache type of server:
#
# define command {
#        command_name check_snmp_uptime_v2
#        command_line $USER1$/check_uptime.pl -2 -f -w -H $HOSTADDRESS$ -C $_HOSTSNMP_COMMUNITY$ -P "$SERVICEPERFDATA$"
# }
#
# 4. Remote server SNMP v3, rest as above
#
#define command {
#        command_name check_snmp_uptime_v3
#        command_line $USER1$/check_uptime.pl -f -w -H $HOSTADDRESS$ -l $_HOSTSNMP_V3_USER$ -x $_HOSTSNMP_V3_AUTH$ -X $_HOSTSNMP_V3_PRIV$ -L sha,aes -P "$SERVICEPERFDATA$"
# }
#
# 5. Example of service definition using above
#
# define service{
#      use				std-service
#      hostgroup_name			all_snmp_hosts
#      service_description		SNMP Uptime
#      max_check_attempts               1
#      check_command			check_snmp_uptime
# }
#
# 6. And this is optional dependency definition for above which makes
#    every SNMP service (service beloning to SNMP servicegroup) on
#    same host dependent on this SNMP Uptime check. Then if SNMP
#    daemon goes down you only receive one alert
#
# define servicedependency{
#        service_description SNMP Uptime
#        dependent_servicegroup_name snmp
# }
#
# ============================= VERSION HISTORY ==============================
#
# 0.1 - sometime 2006 : Simple script for tracking local system uptime
# 0.2 - sometime 2008 : Update to get uptime by SNMP, its now alike my other plugins
# 0.3 -  Nov 14, 2009 : Added getting system info line and using that to decide
#		        format of uptime line and how to process it. Added support
#			for getting uptime with SNMP from windows systems.
#			Added documentation header alike my other plugins.
#			Planned to release it to public, but forgot.
# 0.4  - Dec 19, 2011 : Update to support SNMP v3, released to public
# 0.41 - Jan 13, 2012 : Added bug fix by Rom_UA posted as comment on Nagios Exchange
#			Added version history you're reading right now.
# 0.42 - Feb 13, 2012 : Bug fix to not report WARNING if uptime is not correct output
# 0.5  - Feb 29, 2012 : Added support for "netswitch" engine type that retrieves
#		        snmpEngineTime. Added proper support for sysUpTime interpreting
#			it as 1/100s of a second and converting to days,hours,minutes
#			Changed internal processing structure, now reported uptime
#			info text is based on uptime_minutes and not separate.
# 0.51 - Jun 05, 2012 : Bug fixed for case when when snmp system info is < 3 words.
# 0.52 - Jun 19, 2012 : For switches if snmpEngineTime OID is not available,
#		        the plugin will revert back to checking hostUptime and
#			then sysUptime. Entire logic has in fact been changed
#			to support trying more than just two OIDs. Also added
#			support to specify filename to '-v' option for debug
#		        output to go to instead of console and for '--debug'
#			option as an alias to '--verbose'.
# 0.521 - Oct 4, 2012 : Small bug in one of regex, see issue #11 on github
#
# TODO:
#   0) Add '--extra-opts' to allow to read options from a file as specified
#      at http://nagiosplugins.org/extra-opts. This is TODO for all my plugins
#   1) Add support for ">", "<" and other threshold qualifiers
#      as done in check_snmp_temperature.pl or check_mysqld.pl
#   2) Support for more types, in particular network equipment such as cisco: [DONE]
#      	     sysUpTime is a 32-bit counter in 1/100 of a second, it rolls over after 496 days
#            snmpEngineTime (.1.3.6.1.6.3.10.2.1.3) returns the uptime in seconds and will not
#            roll over, however some cisco switches (29xx) are buggy and it gets reset too.
#            Routers running 12.0(3)T or higher can use the snmpEngineTime object from
#            the SNMP-FRAMEWORK-MIB.  This keeps track of seconds since SNMP engine started.
#   3) Add threshold into perfout as ';warn;crit'
#
# ========================== START OF PROGRAM CODE ===========================

use strict;
use Getopt::Long;

# Nagios specific
our $TIMEOUT;
our %ERRORS;
eval 'use utils qw(%ERRORS $TIMEOUT)';
if ($@) {
 $TIMEOUT = 10;
 %ERRORS = ('OK'=>0,'WARNING'=>1,'CRITICAL'=>2,'UNKNOWN'=>3,'DEPENDENT'=>4);
}

our $no_snmp=0;
eval 'use Net::SNMP';
if ($@) {
  $no_snmp=1;
}

# Version
my $Version='0.52';

# SNMP OID
my $oid_sysSystem = '1.3.6.1.2.1.1.1.0';	     # windows and some unix
my $oid_hostUptime = '1.3.6.1.2.1.25.1.1.0';         # hostUptime, usually unix systems
my $oid_sysUptime = '1.3.6.1.2.1.1.3.0';             # sysUpTime, windows
my $oid_engineTime = '1.3.6.1.6.3.10.2.1.3';         # SNMP-FRAMEWORK-MIB

my @oid_uptime_types = ( ['', '', ''],		      	      # type 0 is reserved
	   [ 'local', '', ''],                                # type 1 is local
           [ 'win', 'sysUpTime', $oid_sysUptime ], 	      # type 2 is windows
	   [ 'unix-host', 'hostUpTime', $oid_hostUptime ],    # type 3 is unix-host
	   [ 'unix-sys', 'sysUpTime', $oid_sysUptime ],       # type 4 is unix-sys
	   [ 'net', 'engineTime', $oid_engineTime ]);         # type 5 is netswitch

# Not used, but perhaps later
my $oid_hrLoad = '1.3.6.1.2.1.25.3.3.1.2.1';
my $oid_sysLoadInt1 = '1.3.6.1.4.1.2021.10.1.5.1';
my $oid_sysLoadInt5 = '1.3.6.1.4.1.2021.10.1.5.2';
my $oid_sysLoadInt15 = '1.3.6.1.4.1.2021.10.1.5.3';

# Standard options
my $o_host = 		undef; 	# hostname
my $o_timeout=  	undef;  # Timeout (Default 10)
my $o_help=		undef; 	# wan't some help ?
my $o_verb=		undef;	# verbose mode
my $o_version=		undef;	# print version
my $o_label=		undef;	# change label instead of printing uptime
my $o_perf=             undef;  # Output performance data (uptime in minutes)
my $o_prevperf=		undef;	# performance data given with $SERVICEPERFDATA$ macro
my $o_warn=             undef;  # WARNING alert if system has been up for < specified number of minutes
my $o_crit=             undef;  # CRITICAL alert if system has been up for < specified number of minutes
my $o_type=             undef;  # type of check (local, auto, unix, win)

# Login and other options specific to SNMP
my $o_port =		161;    # SNMP port
my $o_community =	undef; 	# community
my $o_version2	=	undef;	# use snmp v2c
my $o_login=		undef;	# Login for snmpv3
my $o_passwd=		undef;	# Pass for snmpv3
my $v3protocols=	undef;	# V3 protocol list.
my $o_authproto=	'md5';	# Auth protocol
my $o_privproto=	'des';	# Priv protocol
my $o_privpass= 	undef;	# priv password

## Additional global variables
my %prev_perf=	();     # array that is populated with previous performance data
my $check_type = 0;

sub p_version { print "check_uptime version : $Version\n"; }

sub print_usage {
    print "Usage: $0 [-v [debugfilename]] [-T local|unix-host|unix-sys|win|net] [-H <host> (-C <snmp_community>) [-2] | (-l login -x passwd [-X pass -L <authp>,<privp>) [-p <port>]] [-w <warn minutes> -s <crit minutes>] [-f] [-P <previous perf data from nagios \$SERVICEPERFDATA\$>] [-t <timeout>] | [-V] [--label <string>]\n";
}

sub isnnum { # Return true if arg is not a number
  my $num = shift;
  if ( $num =~ /^(\d+\.?\d*)|(^\.\d+)$/ ) { return 0 ;}
  return 1;
}

sub div_mod { return int( $_[0]/$_[1]) , ($_[0] % $_[1]); }

sub help {
   print "\nUptime Plugin for Nagios (check_uptime) v. ",$Version,"\n";
   print "GPL licence, (c) 2008-2012 William Leibzon\n\n";
   print_usage();
   print <<EOT;

Debug & Console Options:
 -v, --verbose[=FILENAME], --debug[=FILENAME]
   print extra debugging information.
   if filename is specified instead of STDOUT the debug data is written to that file
 -h, --help
   print this help message
 -V, --version
   prints version number

Standard Options:
 -T, --type=auto|local|unix-host|unis-sys|windows|netswitch
   Type of system:
     local           : localhost (executes 'uptime' command), default if no -C or -l
     unix-host       : SNMP check from hostUptime ($oid_hostUptime) OID
     unix-sys        : SNMP check from sysUptime ($oid_sysUptime) OID
     win | windows   : SNMP check from sysUptime ($oid_sysUptime) OID
     net | netswitch : SNMP check from snmpEngineTime ($oid_engineTime) OID
     auto            : Autodetect what system by checking sysSystem OID first, default
 -w, --warning[=minutes]
   Report nagios WARNING alert if system has been up for less then specified
   number of minutes. If no minutes are specified but previous preformance
   data is fed back with -P option then alert is sent ONLY ONCE when
   uptime changes from greater value to smaller
 -c, --critical[=minutes]
   Report nagios CRITICAL alert if system has been up for less then
   specified number of minutes or ONE ALERT if -P option is used and
   system's previous uptime is larger then current on
 -f, --perfparse
   Perfparse compatible output
 -P, --prev_perfdata
   Previous performance data (normally put '-P \$SERVICEPERFDATA\$' in
   nagios command definition). This is recommended if you dont specify
   type of system with -T so that previously checked type of system info
   is reused. This is also used to decide on warning/critical condition
   if number of seconds is not specified with -w or -c.
 --label=[string]
   Optional custom label before results prefixed to results
 -t, --timeout=INTEGER
   timeout for SNMP in seconds (Default: 15)

SNMP Access Options:
 -H, --hostname=HOST
   name or IP address of host to check (if not localhost)
 -C, --community=COMMUNITY NAME
   community name for the SNMP agent (used with v1 or v2c protocols)
 -2, --v2c
   use snmp v2c (can not be used with -l, -x)
 -l, --login=LOGIN ; -x, --passwd=PASSWD
   Login and auth password for snmpv3 authentication
   If no priv password exists, implies AuthNoPriv
 -X, --privpass=PASSWD
   Priv password for snmpv3 (AuthPriv protocol)
 -L, --protocols=<authproto>,<privproto>
   <authproto> : Authentication protocol (md5|sha : default md5)
   <privproto> : Priv protocols (des|aes : default des)
 -p, --port=PORT
   SNMP port (Default 161)
EOT
}

# For verbose output (updated 06/06/12 to write to debug file if specified)
sub verb {
    my $t=shift;
    if (defined($o_verb)) {
        if ($o_verb eq "") {
                print $t,"\n";
        }
        else {
            if (!open(DEBUGFILE, ">>$o_verb")) {
                print $t, "\n";
            }
            else {
                print DEBUGFILE $t,"\n";
                close DEBUGFILE;
            }
        }
    }
}

# load previous performance data
sub process_perf {
 my %pdh;
 my ($nm,$dt);
 foreach (split(' ',$_[0])) {
   if (/(.*)=(.*)/) {
        ($nm,$dt)=($1,$2);
        verb("prev_perf: $nm = $dt");
	# in some of my plugins time_ is to profile how long execution takes for some part of plugin
        # $pdh{$nm}=$dt if $nm !~ /^time_/;
	$pdh{$nm}=$dt;
   }
 }
 return %pdh;
}

sub type_from_name {
  my $type=shift;
  for(my $i=1; $i<scalar(@oid_uptime_types); $i++) {
      if ($oid_uptime_types[$i][0] eq $type) {
          return $i;
      }
   }
   return -1;
}


sub check_options {
    Getopt::Long::Configure ("bundling");
	GetOptions(
   	'v:s'	=> \$o_verb,		'verbose:s'	=> \$o_verb,  "debug:s" => \$o_verb,
        'h'     => \$o_help,    	'help'        	=> \$o_help,
        'H:s'   => \$o_host,		'hostname:s'	=> \$o_host,
        'p:i'   => \$o_port,   		'port:i'	=> \$o_port,
        'C:s'   => \$o_community,	'community:s'	=> \$o_community,
	 '2'	=> \$o_version2,	'v2c'		=> \$o_version2,
	'l:s'	=> \$o_login,		'login:s'	=> \$o_login,
	'x:s'	=> \$o_passwd,		'passwd:s'	=> \$o_passwd,
	'X:s'	=> \$o_privpass,	'privpass:s'	=> \$o_privpass,
	'L:s'	=> \$v3protocols,	'protocols:s'	=> \$v3protocols,
        't:i'   => \$o_timeout,    	'timeout:i'	=> \$o_timeout,
	'V'	=> \$o_version,		'version'	=> \$o_version,
        'f'     => \$o_perf,            'perfparse'     => \$o_perf,
        'w:i'   => \$o_warn,       	'warning:i'   	=> \$o_warn,
        'c:i'   => \$o_crit,      	'critical:i'   	=> \$o_crit,
	'label:s'   => \$o_label,
	'P:s'	=> \$o_prevperf,	'prev_perfdata:s' => \$o_prevperf,
	'T:s'   => \$o_type,            'type:s'        => \$o_type,
    );
    if (defined ($o_help) ) { help(); exit $ERRORS{"UNKNOWN"}};
    if (defined($o_version)) { p_version(); exit $ERRORS{"UNKNOWN"}};

    $o_type = "win" if defined($o_type) && $o_type eq 'windows';
    $o_type = "net" if defined($o_type) && $o_type eq 'netswitch';
    if (defined($o_type) && $o_type ne 'auto' && type_from_name($o_type)==-1) {
	print "Invalid system type specified\n"; print_usage(); exit $ERRORS{"UNNKNOWN"};
    }

    if (!defined($o_community) && (!defined($o_login) || !defined($o_passwd)) ) {
	 $o_type='local' if !defined($o_type) || $o_type eq 'auto';
	 if ($o_type ne 'local') {
            print "Put snmp login info!\n"; print_usage(); exit $ERRORS{"UNKNOWN"}
         }
	 if (defined($o_host)) {
	    print "Why are you specifying hostname without SNMP parameters?\n"; print_usage(); exit $ERRORS{"UNKNOWN"};
	 }
    }
    else {
         $o_type='auto' if !defined($o_type);
         if ($o_type eq 'local' ) {
	     print "Why are you specifying SNMP login for local system???\n"; print_usage(); exit $ERRORS{"UNKNOWN"}
         }
         if (!defined($o_host)) {
             print "Hostname required for SNMP check.\n"; print_usage(); exit $ERRORS{"UNKNOWN"};
         }
	 if ($no_snmp) {
	     print "Can't locate Net/SNMP.pm\n"; print_usage(); exit $ERRORS{"UNKNOWN"};
	 }
    }

    # check snmp information
    if ((defined($o_login) || defined($o_passwd)) && (defined($o_community) || defined($o_version2)) )
	{ print "Can't mix snmp v1,2c,3 protocols!\n"; print_usage(); exit $ERRORS{"UNKNOWN"}}
    if (defined ($v3protocols)) {
	if (!defined($o_login)) { print "Put snmp V3 login info with protocols!\n"; print_usage(); exit $ERRORS{"UNKNOWN"}}
	my @v3proto=split(/,/,$v3protocols);
	if ((defined ($v3proto[0])) && ($v3proto[0] ne "")) {$o_authproto=$v3proto[0];  }	# Auth protocol
	if (defined ($v3proto[1])) {$o_privproto=$v3proto[1];	}	# Priv  protocol
	if ((defined ($v3proto[1])) && (!defined($o_privpass)))
	  { print "Put snmp V3 priv login info with priv protocols!\n"; print_usage(); exit $ERRORS{"UNKNOWN"}}
    }

    if (defined($o_timeout) && (isnnum($o_timeout) || ($o_timeout < 2) || ($o_timeout > 60)))
	{ print "Timeout must be >1 and <60 !\n"; print_usage(); exit $ERRORS{"UNKNOWN"}}
    if (!defined($o_timeout)) {$o_timeout=$TIMEOUT+5;}

    if (defined($o_prevperf)) {
        if (defined($o_perf)) {
               %prev_perf=process_perf($o_prevperf);
	       $check_type = $prev_perf{type} if $o_type eq 'auto' && exists($prev_perf{tye}) && exists($oid_uptime_types[$prev_perf{type}][0]);
	}
        else {
               print "need -f option first \n"; print_usage(); exit $ERRORS{"UNKNOWN"};
        }
    }

    if ($o_type eq 'auto') {
        $check_type=0;
    }
    else {
        $check_type = type_from_name($o_type);
    }
}

sub create_snmp_session {
  my ($session,$error);

  if ( defined($o_login) && defined($o_passwd)) {
    # SNMPv3 login
    if (!defined ($o_privpass)) {
     verb("SNMPv3 AuthNoPriv login : $o_login, $o_authproto");
     ($session, $error) = Net::SNMP->session(
      -hostname   	=> $o_host,
      -version		=> '3',
      -port      	=> $o_port,
      -username		=> $o_login,
      -authpassword	=> $o_passwd,
      -authprotocol	=> $o_authproto,
      -timeout          => $o_timeout
     );
    } else {
     verb("SNMPv3 AuthPriv login : $o_login, $o_authproto, $o_privproto");
     ($session, $error) = Net::SNMP->session(
      -hostname   	=> $o_host,
      -version		=> '3',
      -username		=> $o_login,
      -port      	=> $o_port,
      -authpassword	=> $o_passwd,
      -authprotocol	=> $o_authproto,
      -privpassword	=> $o_privpass,
      -privprotocol     => $o_privproto,
      -timeout          => $o_timeout
     );
    }
  } else {
    if (defined ($o_version2)) {
    # SNMPv2c Login
      verb("SNMP v2c login");
      ($session, $error) = Net::SNMP->session(
       -hostname  => $o_host,
       -version   => 2,
       -community => $o_community,
       -port      => $o_port,
       -timeout   => $o_timeout
      );
    } else {
    # SNMPV1 login
      verb("SNMP v1 login");
      ($session, $error) = Net::SNMP->session(
       -hostname  => $o_host,
       -community => $o_community,
       -port      => $o_port,
       -timeout   => $o_timeout
      );
    }
  }
  if (!defined($session)) {
     printf("ERROR opening session: %s.\n", $error);
     exit $ERRORS{"UNKNOWN"};
  }

  return $session;
}

$SIG{'ALRM'} = sub {
 print "Alarm timeout\n";
 exit $ERRORS{"UNKNOWN"};
};

########## MAIN #######
my $system_info="";
my $uptime_info=undef;
my $uptime_minutes=undef;
my $perf_out="";
my $status=0;
my $uptime_output;
my ($days, $hrs, $mins);

check_options();

# Check gobal timeout if snmp screws up
if (defined($o_timeout)) {
  verb("Alarm at $o_timeout + 5");
  alarm($o_timeout+5);
}

if ($check_type==1) {  # local
  # Process unix uptime command output
  $uptime_output=`uptime`;
  verb("Local Uptime Result is: $uptime_output");
  if ($uptime_output =~ /(\d+)\s+days?,\s+(\d+)\:(\d+)/) {
     ($days, $hrs, $mins) = ($1, $2, $3);
  }
  elsif ($uptime_output =~ /up\s+(\d+)\shours?\s+(\d+)/) {
     ($days, $hrs, $mins) = (0, $1, $2);
  }
  elsif ($uptime_output =~ /up\s+(\d+)\:(\d+)/) {
     ($days, $hrs, $mins) = (0, $1, $2);
  }
  elsif ($uptime_output =~ /up\s+(\d+)\s+min/) {
     ($days, $hrs, $mins) = (0,0,$1);
  }
  elsif ($uptime_output =~ /up\s+(\d+)s+days?,s+(\d+)s+min/) {
     ($days, $hrs, $mins) = ($1,0,$2);
  }
  else {
     $uptime_info = "up ".$uptime_output;
  }
  if (defined($days) && defined($hrs) && defined($mins)) {
     $uptime_minutes = $days*24*60+$hrs*60+$mins;
  }
  my @temp=split(' ',`uname -a`);
  if (scalar(@temp)<3) {
        $system_info=`uname -a`;
  }
  else {
        $system_info=join(' ',$temp[0],$temp[1],$temp[2]);
  }
}
else {
  # SNMP connection
  my $session=create_snmp_session();
  my $result=undef;
  my $oid="";
  my $guessed_check_type=0;

  if ($check_type==0){
      $result = $session->get_request(-varbindlist=>[$oid_sysSystem]);
      if (!defined($result)) {
            printf("ERROR: Can not retrieve $oid_sysSystem table: %s.\n", $session->error);
            $session->close;
            exit $ERRORS{"UNKNOWN"};
      }
      verb("$o_host SysInfo Result from OID $oid_sysSystem: $result->{$oid_sysSystem}");
      if ($result->{$oid_sysSystem} =~ /Windows/) {
	  $guessed_check_type=2;
	  verb('Guessing Type: 2 = windows');
      }
      if ($result->{$oid_sysSystem} =~ /Cisco/) {
	  $guessed_check_type=5;
	  verb('Guessing Type: 5 = netswitch');
      }
      if ($guessed_check_type==0) {
	  $guessed_check_type=3; # will try hostUptime first
      }
      $oid=$oid_uptime_types[$guessed_check_type][2];
  }
  else {
      $oid=$oid_uptime_types[$check_type][2];
  }

  do {
      $result = $session->get_request(-varbindlist=>[$oid,$oid_sysSystem]);
      if (!defined($result)) {
          if ($check_type!=0) {
              printf("ERROR: Can not retrieve uptime OID table $oid: %s.\n", $session->error);
              $session->close;
              exit $ERRORS{"UNKNOWN"};
          }
          else {
              if ($session->error =~ /noSuchName/) {
		  if ($guessed_check_type==4) {
                      verb("Received noSuchName error for sysUpTime OID $oid. Giving up.");
                      $guessed_check_type=0;
		  }
	          if ($guessed_check_type==3) {
            	      verb("Received noSuchName error for hostUpTime OID $oid, will now try sysUpTime");
		      $guessed_check_type=4;
	          }
	          else {
		      verb("Received noSuchName error for OID $oid, will now try hostUpTime");
		      $guessed_check_type=3;
		  }
		  if ($guessed_check_type!=0) {
		      $oid=$oid_uptime_types[$guessed_check_type][2];
		  }
	      }
	      else {
		  printf("ERROR: Can not retrieve uptime OID table $oid: %s.\n", $session->error);
         	  $session->close;
         	  exit $ERRORS{"UNKNOWN"};
	      }
	  }
      }
      else {
          if ($check_type==0) {
	      $check_type=$guessed_check_type;
	  }
      }
  }
  while (!defined($result) && $guessed_check_type!=0);

  $session->close;
  if ($check_type==0 && $guessed_check_type==0) {
        printf("ERROR: Can not autodetermine proper uptime OID table. Giving up.\n");
        exit $ERRORS{"UNKNOWN"};
  }

  my ($days, $hrs, $mins);
  $uptime_output=$result->{$oid};
  verb("$o_host Uptime Result from OID $oid: $uptime_output");

  if ($uptime_output =~ /(\d+)\s+days?,\s+(\d+)\:(\d+)/) {
    ($days, $hrs, $mins) = ($1, $2, $3);
  }
  elsif ($uptime_output =~ /(\d+)\s+hours?,\s+(\d+)\:(\d+)/) {
    ($days, $hrs, $mins) = (0, $1, $2);
  }
  elsif ($uptime_output =~ /(\d+)\s+min/) {
    ($days, $hrs, $mins) = (0, 0, $1);
  }
  if (defined($days) && defined($hrs) && defined($mins)) {
    $uptime_minutes = $days*24*60+$hrs*60+$mins;
  }
  elsif ($uptime_output =~ /^(\d+)$/) {
    my $upnum = $1;
    if ($oid eq $oid_sysUptime) {
	$uptime_minutes = $upnum/100/60;
    }
    elsif ($oid eq $oid_engineTime) {
	$uptime_minutes = $upnum/60;
    }
  }
  else {
    $uptime_info = "up ".$uptime_output;
  }
  my @temp=split(' ',$result->{$oid_sysSystem});
  if (scalar(@temp)<3) {
	$system_info=$result->{$oid_sysSystem};
  }
  else {
	$system_info=join(' ',$temp[0],$temp[1],$temp[2]);
  }
}

if (defined($uptime_minutes) && !defined($uptime_info)) {
  ($hrs,$mins) = div_mod($uptime_minutes,60);
  ($days,$hrs) = div_mod($hrs,24);
  $uptime_info = "up ";
  $uptime_info .= "$days days " if $days>0;
  $uptime_info .= "$hrs hours " if $hrs>0;
  $uptime_info .= "$mins minutes";
}

verb("System Type: $check_type (".$oid_uptime_types[$check_type][0].")");
verb("System Info: $system_info") if $system_info;
verb("Uptime Text: $uptime_info") if defined($uptime_info);
verb("Uptime Minutes: $uptime_minutes") if defined($uptime_minutes);

if (!defined($uptime_info)) {
  $uptime_info = "Can not determine uptime";
  $status = 3;
}

if (defined($o_perf)) {
  $perf_out = "type=$check_type";
  $perf_out .= " uptime_minutes=$uptime_minutes" if defined($uptime_minutes);
}

if (defined($uptime_minutes)) {
  if (defined($o_prevperf)) {
   	$status = 1 if defined($o_warn) && exists($prev_perf{uptime_minutes}) && $prev_perf{uptime_minutes} > $uptime_minutes;
   	$status = 2 if defined($o_crit) && exists($prev_perf{uptime_minutes}) && $prev_perf{uptime_minutes} > $uptime_minutes;
  }
  else {
   	$status = 1 if defined($o_warn) && !isnnum($o_warn) && $o_warn >= $uptime_minutes;
   	$status = 2 if defined($o_crit) && !isnnum($o_crit) && $o_crit >= $uptime_minutes;
  }
}
alarm(0);

my $exit_status="UNKNOWN";
$exit_status="OK" if $status==0;
$exit_status="WARNING" if $status==1;
$exit_status="CRITICAL" if $status==2;
$exit_status="UNKNOWN" if $status==3;
$exit_status="$o_label $exit_status" if defined($o_label);
print "$exit_status: $system_info";
print " - $uptime_info";
print " | ",$perf_out if $perf_out;
print "\n";
exit $status;