/usr/share/doc/dx/help/dxall397 is in dx-doc 1:4.4.4-9.
This file is owned by root:root, with mode 0o644.
The actual contents of the file can be viewed below.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 | #!F-adobe-helvetica-medium-r-normal--18*
#!N
#!CDarkGreen #!N #!Rsetatdb Setting Interactor Attributes #!N #!EC #!N #!N You
can have several instances of the same interactor. Each instance can
be a different style (stepper, dial, or slider) and can have
a different increment value. However, all instances of an interactor have
the same value and the same minimum and maximum limits. As
you change the value or range of one instance, the other
instances of that interactor are automatically updated. #!N #!N To change
the #!F-adobe-times-medium-i-normal--18* range #!EF of values of an interactor, select the
interactor, and select the #!F-adobe-times-bold-r-normal--18* Set Attributes... #!EF option in the
#!F-adobe-times-bold-r-normal--18* Edit #!EF menu; or double-click on the interactor in the
Control Panel. The #!F-adobe-times-bold-r-normal--18* Set Attributes... #!EF dialog box ( #!Lsetlim80,dxall397 f Figure 80 #!EL
) appears. #!N #!N #!Cbrown #!F-adobe-times-medium-r-normal--18* #!Rsetlim80 #!N Graphics omitted from
Online Documentation. Please see the manual. #!N #!N Figure 80. Set
Attributes Dialog Box #!EF #!N #!EC In this box you can:
#!N #!I0 #!N #!F-adobe-times-medium-r-normal--18* #!N #!N #!I30 #!N o Set maximum
and minimum values. #!N #!I30 #!N o Change the step increment.
#!N #!I30 #!N o Change the number of decimal places displayed.
(In the case of an integer interactor, the decimal place field
is disabled.) #!N #!I30 #!N o Choose whether to update the
image continuously as you change the interactor values, or to update
only when the mouse button is released. This applies only when
#!F-adobe-times-bold-r-normal--18* Execute on Change #!EF is enabled. Note: Many interactor types
can also be data-driven, meaning that their attributes are derived at
run time from data in the visual program. See #!Lddinter,dxall434 h Using Data-Driven Interactors #!EL .
#!N #!I0 #!N #!EF #!N The increment and update options can
be applied to the either just the current instance or to
all instances of the interactor. To affect all instances, click on
the option box for the attribute you want to set (increment
or update), and select the Global option from option menu. To
affect only the current instance, select the Local option. Having multiple
instances of an interactor with different increments allows coarse and fine
controls. For example, you may want one instance of a scalar
interactor to change by increments of 1.0, another instance by 0.10,
and a third instance by 0.01. Note that the "global" option
will not override interactors which have been explicitly set to "local."
#!N #!N #!N #!F-adobe-times-medium-i-normal--18* Next Topic #!EF #!N #!N #!Ltall399,dxall399 h Vector interactors #!EL #!N
#!F-adobe-times-medium-i-normal--18* #!N
|