/usr/share/doc/dx/help/dxall962 is in dx-doc 1:4.4.4-9.
This file is owned by root:root, with mode 0o644.
The actual contents of the file can be viewed below.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 | #!F-adobe-helvetica-medium-r-normal--18*
#!N
#!N #!Rswitch
Switch #!N #!N Category #!N #!N #!Lcatflow,dxall755 h Flow Control #!EL #!N #!N Function #!N
#!N Selects one input from a list. #!N #!N Syntax #!CForestGreen
#!N #!N #!F-adobe-courier-bold-r-normal--18* #!N #!F-adobe-times-bold-r-normal--18* output #!EF = Switch( #!F-adobe-times-bold-r-normal--18* selector,
input, ... #!EF ); #!EF #!N #!N #!EC #!N #!N Inputs
#!T,1,91,276,461,646 #!F-adobe-times-medium-r-normal--14* #!F-adobe-times-bold-r-normal--18* #!N TAB Name TAB Type TAB Default TAB
Description #!EF #!N TAB selector TAB integer TAB 0 TAB object
to be selected #!N TAB input TAB value list, string list,
or object TAB no default TAB selectable object #!N TAB ...
TAB - TAB - TAB more objects to be switched #!N
TAB - TAB - TAB - TAB #!EF #!N #!N Outputs
#!T,1,161,321,646 #!F-adobe-times-medium-r-normal--14* #!F-adobe-times-bold-r-normal--18* #!N TAB Name TAB Type TAB Description #!EF
#!N TAB output TAB object TAB the object switched #!N TAB
- TAB - TAB #!EF #!N #!N Functional Details #!N #!N
This module selects a specified object from #!F-adobe-times-bold-r-normal--18* input #!EF and
passes it through to #!F-adobe-times-bold-r-normal--18* output #!EF . #!N #!I0 #!N
#!N #!I0 #!N #!F-adobe-times-bold-r-normal--18* #!F-adobe-times-bold-r-normal--18* selector #!EF #!EF #!I50 #!N specifies
which of the #!F-adobe-times-medium-i-normal--18* n #!EF input objects are to be
passed to #!F-adobe-times-bold-r-normal--18* output #!EF . If the specified value is
1, the first #!F-adobe-times-bold-r-normal--18* input #!EF object (the second input to
the module itself) is passed through; if the specified value is
2, the second input object (the third input to the module)
is passed through; and so on. #!N #!N If the specified
value is รณ 0 or larger than #!F-adobe-times-medium-i-normal--18* n #!EF ,
#!F-adobe-times-bold-r-normal--18* output #!EF is NULL. #!N #!I0 #!N #!F-adobe-times-bold-r-normal--18* #!F-adobe-times-bold-r-normal--18* input
#!EF #!EF #!I50 #!N specifies an input that may or may
not be passed to output. #!I0 #!N #!N A single Switch
module can accept a maximum of 21 input objects. In the
user interface, the default number of enabled tabs is two. (Tabs
can be added to the module icon and removed with the
appropriate #!F-adobe-times-bold-r-normal--18* ...Input Tab #!EF options in the #!F-adobe-times-bold-r-normal--18* Edit #!EF
pull-down menu of the VPE.) Note: In the user interface you
may find it helpful to use the first output of the
Selector interactor as the first input ( #!F-adobe-times-bold-r-normal--18* selector #!EF )
to Switch. See #!Lselint,dxall430 h Selector and SelectorList Interactors #!EL in IBM Visualization Data Explorer User's Guide
for more information. #!N #!N Components #!N #!N All input components
are propagated to the output. #!N #!N Example Visual Programs #!CForestGreen
#!N #!N #!F-adobe-courier-bold-r-normal--18* #!N AlternateVisualizations.net #!N ConnectingScatteredPoints.net #!N UsingSwitchAndRoute.net #!N SIMPLE/Switch.net
#!EF #!N #!N #!EC #!N #!N See Also #!N #!N #!Lcollect,dxall788 h Collect #!EL
, #!Lroute,dxall929 h Route #!EL #!N #!N #!Lxmod,dxall263 h Data Explorer Execution Model #!EL in IBM Visualization Data Explorer User's
Guide. #!N #!N #!N #!F-adobe-times-medium-i-normal--18* Next Topic #!EF #!N #!N #!Lsystem,dxall963 h System #!EL
#!N #!F-adobe-times-medium-i-normal--18* #!N
|