This file is indexed.

/usr/share/psychtoolbox-3/PsychCal/MeasMonSpd.m is in psychtoolbox-3-common 3.0.9+svn2579.dfsg1-1.

This file is owned by root:root, with mode 0o644.

The actual contents of the file can be viewed below.

  1
  2
  3
  4
  5
  6
  7
  8
  9
 10
 11
 12
 13
 14
 15
 16
 17
 18
 19
 20
 21
 22
 23
 24
 25
 26
 27
 28
 29
 30
 31
 32
 33
 34
 35
 36
 37
 38
 39
 40
 41
 42
 43
 44
 45
 46
 47
 48
 49
 50
 51
 52
 53
 54
 55
 56
 57
 58
 59
 60
 61
 62
 63
 64
 65
 66
 67
 68
 69
 70
 71
 72
 73
 74
 75
 76
 77
 78
 79
 80
 81
 82
 83
 84
 85
 86
 87
 88
 89
 90
 91
 92
 93
 94
 95
 96
 97
 98
 99
100
101
102
103
104
105
106
function [spd,S] = MeasMonSpd(window, settings, S, syncMode, whichMeterType, bitsppClut)
% [spd,S] = MeasMonSpd(window, settings, [S], [syncMode], [whichMeterType], [bitsppClut])
%
% Measure the Spd of a series of monitor settings.
%
% This routine is specific to go with CalibrateMon,
% as it depends on the action of SetMon. 
%
% If whichMeterType is passed and set to 0, then the routine
% returns random spectra.  This is useful for testing when
% you don't have a meter.
%
% Other valid types:
%  1 - Use PR650 (default)
%  2 - Use CVI
%
% 10/26/93  dhb	  Wrote it based on ccc code.
% 11/12/93  dhb	  Modified to use SetColor.
% 8/11/94	dhb	  Sync mode.
% 8/15/94   dhb	  Sync mode as argument, allow S to be [] for default.
% 4/12/97   dhb   New toolbox compatibility, take window and bits args.
% 8/26/97   dhb   pbe Add noMeterAvail arg.
% 4/7/99    dhb   Add argument for radius board. Compact default arg code.
% 8/14/00   dhb   Call to CMETER('SetParams') conditional on OS9.
% 8/20/00   dhb   Remove bits arg to SetColor.
% 8/21/00   dhb   Remove dependence on RADIUS flag.  This is now handled inside of SetColor.
%	        dhb   Change calling conventions to remove unused args.
% 9/14/00   dhb   Sync mode is not actually used.  Arg still passed for backwards compat.
% 2/27/02   dhb   Change noMeterAvail to whichMeterType.

% Declare Bits++ box global
global g_usebitspp;

% If the global flag for using Bits++ is empty, then it hasn't been
% initialized and default it to 0.
if isempty(g_usebitspp)
    g_usebitspp = 0;
end

% Check args and make sure window is passed right.
usageStr = 'Usage: [spd,S] = MeasMonSpd(window, settings, [S], [syncMode], [whichMeterType])';
if nargin < 2 || nargin > 6 || nargout > 2
	error(usageStr);
end
if size(window,1) ~= 1 || size(window,2) ~= 1
	error(usageStr);
end

% Set defaults
defaultS = [380 5 81];
defaultSync = 0;
defaultWhichMeterType = 1;

% Get the current gamma table.
if g_usebitspp
    theClut = bitsppClut;
else
    theClut = Screen('ReadNormalizedGammaTable',window);
end

% Check args and set defaults
if nargin < 5 || isempty(whichMeterType)
	whichMeterType = defaultWhichMeterType;
end
if nargin < 4 || isempty(syncMode)
	syncMode = defaultSync;
end
if nargin < 3 || isempty(S)
	S = defaultS;
end

[null, nMeas] = size(settings);
spd = zeros(S(3), nMeas);
for i = 1:nMeas
    % Set the color.
    
    % Measure spectrum
    switch whichMeterType
        case 0
            theClut(2,:) = settings(:, i)';
            if g_usebitspp
                BitsPlusSetClut(window, theClut .* (2^16 - 1), [], false);
                Screen('Flip', window, 0, 1);
            else
                Screen('LoadNormalizedGammaTable', window, theClut);
            end
            spd(:,i) = sum(settings(:, i)) * ones(S(3), 1);
            WaitSecs(.1);
        case 1
            theClut(2,:) = settings(:, i)';
            if g_usebitspp
                BitsPlusSetClut(window, theClut .* (2^16 - 1), [], false);
                Screen('Flip', window, 0, 1);
            else
                Screen('LoadNormalizedGammaTable',window, theClut);
            end
            spd(:,i) = MeasSpd(S);
        case 2
            error('CVI interface not yet ported to PTB-3.');
            cviCal = LoadCVICalFile;
            spd(:,i) =  CVICalibratedDarkMeasurement(cviCal, S, [], [], [], ...
                                                     window, 1, settings(:,i));
        otherwise
            error('Invalid meter type set');
    end
end