1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 | # $Id$
#
# HylaFAX Facsimile Software
#
# Copyright (c) 1990-1996 Sam Leffler
# Copyright (c) 1991-1996 Silicon Graphics, Inc.
# HylaFAX is a trademark of Silicon Graphics, Inc.
#
# Permission to use, copy, modify, distribute, and sell this software and
# its documentation for any purpose is hereby granted without fee, provided
# that (i) the above copyright notices and this permission notice appear in
# all copies of the software and related documentation, and (ii) the names of
# Sam Leffler and Silicon Graphics may not be used in any advertising or
# publicity relating to the software without the specific, prior written
# permission of Sam Leffler and Silicon Graphics.
#
# THE SOFTWARE IS PROVIDED "AS-IS" AND WITHOUT WARRANTY OF ANY KIND,
# EXPRESS, IMPLIED OR OTHERWISE, INCLUDING WITHOUT LIMITATION, ANY
# WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
#
# IN NO EVENT SHALL SAM LEFFLER OR SILICON GRAPHICS BE LIABLE FOR
# ANY SPECIAL, INCIDENTAL, INDIRECT OR CONSEQUENTIAL DAMAGES OF ANY KIND,
# OR ANY DAMAGES WHATSOEVER RESULTING FROM LOSS OF USE, DATA OR PROFITS,
# WHETHER OR NOT ADVISED OF THE POSSIBILITY OF DAMAGE, AND ON ANY THEORY OF
# LIABILITY, ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE
# OF THIS SOFTWARE.
#
#
# Generic Class 2 modem configuration.
#
# EDIT THIS CONFIGURATION TO REFLECT YOUR SETUP
#
# BEGIN-SERVER
#CountryCode: 1 # USA
#LongDistancePrefix: 1
#InternationalPrefix: 011
#AreaCode: 415
#DialStringRules: etc/dialrules
#FAXNumber: +1.999.555.1212
#LocalIdentifier: "NothingSetup" # default is canonical FAXNumber
#ServerTracing: 1 # log server-related operations
#SessionTracing: 11 # log server-related operations
#RecvFileMode: 0600 # recvd facsimile are not public
#LogFileMode: 0600 # private log files
#DeviceMode: 0600 # device is accessible only to uucp/fax
#GettyArgs: "-h %l dx_%s" # requires modem to auto-detect fax/data
#QualifyTSI: etc/tsi # accept facsimile from anyone
#SpeakerVolume: off # machine's are already too loud
#RingsBeforeAnswer: 1 # answer on first ring
#TagLineFont: etc/lutRS18.pcf # tag line font
#TagLineFormat: "From %%l|%c|Page %%P of %%T"
#MaxBadCalls: 5 # max 5 consecutive bad calls
#PostScriptTimeout: 300 # 5 minute timeout on PostScript jobs
#MaxSendPages: 25 # max pages in an outbound job
#MaxRecvPages: 25 # max pages in an inbound job
#ContCoverPage: etc/cover.templ # enable continuation cover pages
#MaxConcurrentCalls: 1 # serialize jobs to the same dest
#TimeOfDay: "Any" # outbound jobs any day, any time
# END-SERVER
#
# Modem-related stuff: should reflect modem command interface
# and hardware connection/cabling (e.g. flow control).
#
ModemType: Class2 # use this to supply a hint
#ModemRate: 19200 # max rate for DCE-DTE communication
#ModemFlowControl: xonxoff # XON/XOFF flow control assumed
#ModemSetupDTRCmd: AT&D2 # setup so DTR drop resets modem
#ModemSetupDCDCmd: AT&C1 # setup so DCD reflects carrier (or not)
#
# We can append the "@" symbol to the dial string so that
# the modem will wait 5 seconds before attempting to connect
# and return result codes that distinguish between no carrier
# and no answer. This makes it possible to avoid problems with
# repeatedly dialing a number that doesn't have a fax machine
# (kudos to Stuart Lynne for this trick.)
#
# NB: If you need to prefix phone numbers to get through a PBX,
# put it in the ModemDialCmd; e.g. "DT9%s@".
#
#ModemDialCmd: ATDT%s # T for tone dialing
#
# Other possible configuration stuff. The default strings are
# shown below. Only those that are different from the defaults
# need to be included in the configuration file.
#
#ModemResetCmds: "" # stuff to do when modem is reset
#ModemAnswerCmd: ATA # use this to answer phone
#ModemNoFlowCmd: AT&K # disable flow control cmd
#ModemHardFlowCmd: AT&K3 # hardware flow control cmd
#ModemSoftFlowCmd: AT&K4 # software flow control cmd
#ModemNoAutoAnswerCmd: ATS0=0 # disable auto-answer
#
# Set modem speaker volume commands: OFF QUIET LOW MEDIUM HIGH.
# Note that we both turn the speaker on/off and set volume.
#
#ModemSetVolumeCmd: "ATM0 ATL0M1 ATL1M1 ATL2M1 ATL3M1"
#ModemEchoOffCmd: ATE0 # disable command echo
#ModemVerboseResultsCmd: ATV1 # enable verbose command results
#ModemResultCodesCmd: ATQ0 # enable result codes
#ModemOnHookCmd: ATH0 # place phone on hook (hangup)
#ModemSoftResetCmd: ATZ # do soft reset of modem
#ModemSoftResetCmdDelay: 3000 # pause after soft reset
#ModemWaitTimeCmd: ATS7=60 # wait 60 seconds for carrier
#ModemCommaPauseTimeCmd: ATS8=2 # comma pause time is 2 seconds
#ModemRecvFillOrder: LSB2MSB # bit order of received facsimile
#ModemSendFillOrder: LSB2MSB # bit order modem expects for transmit
#
# Configuration parameters for Class 2 modems.
#
Class2Cmd: AT+FCLASS=2 # command to enter class 2
Class2BORCmd: AT+FBOR=0 # bit order for phase B/C/D (direct)
Class2RELCmd: AT+FREL=1 # byte-align EOL codes on recv
Class2CQCmd: "" # commands to enable copy quality proc.
Class2AbortCmd: AT+FK # abort session command
Class2CQQueryCmd: AT+FCQ=? # query for copy quality capabilities
Class2DCCQueryCmd: AT+FDCC=? # query for modem capabilities
Class2TBCCmd: AT+FTBC=0 # setup stream mode
Class2CRCmd: AT+FCR=1 # enable capability to receive
Class2PHCTOCmd: AT+FPHCTO=30 # set phase C timeout parameter
Class2BUGCmd: AT+FBUG=1 # enable HDLC frame tracing
Class2LIDCmd: AT+FLID # set local identifier command
Class2DCCCmd: AT+FDCC # set modem capabilities command
Class2DISCmd: AT+FDIS # set session parameters command
Class2DDISCmd: "" # disable pre-dial DIS command hack
Class2CIGCmd: AT+FCIG # set polling identifier command
Class2PTSCmd: AT+FPTS # set post-page status command
Class2SPLCmd: AT+FSPL # set polling indicator command
#
# If Class2RecvDataTrigger is not set, then it is set to DC1
#
Class2RecvDataTrigger: "" # character sent to modem to start recv
Class2XmitWaitForXON: yes # if true, wait for XON before send
|