# $Id$
#
# HylaFAX Facsimile Software
#
# Copyright (c) 1990-1996 Sam Leffler
# Copyright (c) 1991-1996 Silicon Graphics, Inc.
# HylaFAX is a trademark of Silicon Graphics, Inc.
# 
# Permission to use, copy, modify, distribute, and sell this software and 
# its documentation for any purpose is hereby granted without fee, provided
# that (i) the above copyright notices and this permission notice appear in
# all copies of the software and related documentation, and (ii) the names of
# Sam Leffler and Silicon Graphics may not be used in any advertising or
# publicity relating to the software without the specific, prior written
# permission of Sam Leffler and Silicon Graphics.
# 
# THE SOFTWARE IS PROVIDED "AS-IS" AND WITHOUT WARRANTY OF ANY KIND, 
# EXPRESS, IMPLIED OR OTHERWISE, INCLUDING WITHOUT LIMITATION, ANY 
# WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.  
# 
# IN NO EVENT SHALL SAM LEFFLER OR SILICON GRAPHICS BE LIABLE FOR
# ANY SPECIAL, INCIDENTAL, INDIRECT OR CONSEQUENTIAL DAMAGES OF ANY KIND,
# OR ANY DAMAGES WHATSOEVER RESULTING FROM LOSS OF USE, DATA OR PROFITS,
# WHETHER OR NOT ADVISED OF THE POSSIBILITY OF DAMAGE, AND ON ANY THEORY OF 
# LIABILITY, ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE 
# OF THIS SOFTWARE.
#

#
# Configuration for a Rockwell-based Class 1 modem.
#    SupraFAX v.32bis		firmware V1.200-C or newer
# (and others)
#
# This configuration file sets up the modem to run at 38.4
# and use RTS/CTS flow control by default.
#
# CONFIG:CLASS1:14400:.*:.*: Manufacturer=ROCKWELL Model=RC32ACL
#
# BEGIN-SERVER
# END-SERVER
#
# Modem-related stuff: should reflect modem command interface
# and hardware connection/cabling (e.g. flow control).
#
ModemType:		Class1		# use class 1 interface
ModemRate:		19200
ModemFlowControl:	rtscts		# default
#
ModemNoFlowCmd:		AT&K		# disable flow control cmd
ModemHardFlowCmd:	AT&K3		# hardware flow control cmd
ModemSoftFlowCmd:	AT&K4		# software flow control cmd
ModemSetupDTRCmd:	AT&D3		# setup so DTR drop resets modem
ModemSetupDCDCmd:	AT&C1		# setup so DCD reflects carrier (or not)
ModemSetupAACmd:	AT+FAA=0	# in case modem supports Class 2 also
#
ModemMfrQueryCmd:	!Rockwell	# no way to query modem
ModemModelQueryCmd:	!RC32ACL	# not always right
ModemRevQueryCmd:	ATI3