This file is indexed.

/etc/sane.d/mustek_pp.conf is in libsane-common 1.0.27-1~experimental3ubuntu2.

This file is owned by root:root, with mode 0o644.

The actual contents of the file can be viewed below.

  1
  2
  3
  4
  5
  6
  7
  8
  9
 10
 11
 12
 13
 14
 15
 16
 17
 18
 19
 20
 21
 22
 23
 24
 25
 26
 27
 28
 29
 30
 31
 32
 33
 34
 35
 36
 37
 38
 39
 40
 41
 42
 43
 44
 45
 46
 47
 48
 49
 50
 51
 52
 53
 54
 55
 56
 57
 58
 59
 60
 61
 62
 63
 64
 65
 66
 67
 68
 69
 70
 71
 72
 73
 74
 75
 76
 77
 78
 79
 80
 81
 82
 83
 84
 85
 86
 87
 88
 89
 90
 91
 92
 93
 94
 95
 96
 97
 98
 99
100
101
102
103
# For documentation see sane-mustek_pp(5)

# Global options:
# ===============
#
# option no_epp
#
#	    Disable parallel port mode EPP: works around a known bug in
#	    the Linux parport code. Enable this option, if the backend
#	    hangs when trying to access the parallel port in EPP mode:
#
#	          # SANE_DEBUG_SANEI_PA4S2=128 scanimage -L
#	          ...
#  hangs here  -> [sanei_pa4s2] sanei_pa4s2_readbyte: read in EPP mode
#	 
# Scanner definition template:
# ============================
#
#  scanner <name> <port> <type>
#     option <optname> <optval>?
#     option <optname> <optval>?
#     ...
#
#  where:
#
#     <name> is an arbitrary name for the scanner (eg. Mustek-1200CP)
#
#     <port> is the parallel port to which the scanner is connected
#            Possible values are 0x378, 0x278, and 0x3bc. For Linux, the
#            mapping between ports an numbers is different for kernel
#            version 2.2 and 2.4. Port 0x378 corresponds to lp0 on 2.4 kernel.
#            If you are using libieee1284, you can as well use parport0, etc..
#	     If you use the magic value * the port is probed.
#
#     <type> is an identification of the scanner type.
#            Possible values are:
#              - cis600    (for Mustek 600CP & OEM versions),
#              - cis1200   (for Mustek 1200CP & OEM versions),
#              - cis1200+  (for Mustek 1200CP+ & OEM versions),
#              - ccd300    (for Mustek 600 III EPP & OEM versions)
#	       - ... more types will be added in the future
#     
#     <optname> is a name of an option, and <optval> an optional value
#               for the option.
#               Currently available options for *CIS* type scanners are:
#                 - top_adjust <value>: 
#                      Vertical adjustment of origin, in millimeter.
#                      Values between -5.0 and +5.0 mm are possible 
#                      (floating point).
#                      Default: 0.0
#                 - slow_skip: 
#                      Boolean option. Disables fast skipping to the start
#                      of the scan region. May be necessary in case fast
#                      skipping results in inaccuracies.
#                      Default: fast skipping enabled             
#                 - bw <value>:
#                      Black/white discrimination value for lineart scans.
#                      Pixel values below that value are considered black,
#                      others are considered white. Range: 0-255.
#                      Default: 127
#
#		Currently available options for *CCD* type scanners are:
#		  - wait_bank <value>
#		       usecs to wait for a bank change. Positive integer
#		       values are possible. You shouldn't mess with this
#		       parameter.
#		       Default: 700
#		  - bw <value>
#                      Black/white discrimination value for lineart scans.
#                      Pixel values below that value are considered black,
#                      others are considered white. Range: 0-255.
#                      Default: 127
#		  - top <value>
#		       Scanlines to skip to the top area. Positive integer
#		       values are possible. 47 and 56 are values I know of.
#		       Default: 47
#
#
# Example for a LifeTec LT9350 (Mustek 1200CP clone):
#
#    scanner LT9350 0x378 cis1200
#       option top_adjust 0
#       option bw 127
#
# Example for Mustek 6000P
#
#    scanner 6000P 0x378 ccd300
#        option top 56
#
#
# Uncomment/customize to your needs
#
# scanner Mustek-600CP 0x378 cis600
# scanner Mustek-1200CP 0x378 cis1200
# scanner Mustek-1200CP+ 0x378 cis1200+
# scanner Mustek-600-IIIEP 0x378 ccd300
#
# auto probing:
#
# scanner mustek-cis600 * cis600
# scanner mustek-cis1200 * cis1200
# scanner mustek-cis1200+ * cis1200+
# scanner mustek-ccd300 * ccd300