/usr/share/perl5/SNMP/Info/PowerEthernet.pm is in libsnmp-info-perl 3.39-1.
This file is owned by root:root, with mode 0o644.
The actual contents of the file can be viewed below.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 | # SNMP::Info::PowerEthernet
# $Id$
#
# Copyright (c) 2008 Bill Fenner
# All rights reserved.
#
# Redistribution and use in source and binary forms, with or without
# modification, are permitted provided that the following conditions are met:
#
# * Redistributions of source code must retain the above copyright notice,
# this list of conditions and the following disclaimer.
# * Redistributions in binary form must reproduce the above copyright
# notice, this list of conditions and the following disclaimer in the
# documentation and/or other materials provided with the distribution.
# * Neither the name of the University of California, Santa Cruz nor the
# names of its contributors may be used to endorse or promote products
# derived from this software without specific prior written permission.
#
# THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS"
# AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
# IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
# ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT OWNER OR CONTRIBUTORS BE
# LIABLE FOR # ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR
# CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF
# SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS
# INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN
# CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE)
# ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE
# POSSIBILITY OF SUCH DAMAGE.
package SNMP::Info::PowerEthernet;
use strict;
use Exporter;
use SNMP::Info;
@SNMP::Info::PowerEthernet::ISA = qw/SNMP::Info Exporter/;
@SNMP::Info::PowerEthernet::EXPORT_OK = qw//;
use vars qw/$VERSION %MIBS %FUNCS %GLOBALS %MUNGE/;
$VERSION = '3.39';
%MIBS = ( 'POWER-ETHERNET-MIB' => 'pethPsePortDetectionStatus' );
%GLOBALS = ();
%FUNCS = (
# parts of pethPsePortTable
'peth_port_admin' => 'pethPsePortAdminEnable',
'peth_port_status' => 'pethPsePortDetectionStatus',
'peth_port_class' => 'pethPsePortPowerClassifications',
# pethMainPseTable
'peth_power_watts' => 'pethMainPsePower',
'peth_power_status' => 'pethMainPseOperStatus',
'peth_power_consumption' => 'pethMainPseConsumptionPower',
'peth_power_threshold' => 'pethMainPseUsageThreshold',
);
%MUNGE = ();
# POWER-ETHERNET-MIB doesn't define a mapping of its
# "module"/"port" index to ifIndex. Different vendors
# do this in different ways. This is a poor fallback:
# if all of the module values = 1, return the port number
# on the assumption that port number = ifindex.
# If there is a module != 1, this heuristic doesn't work
# so returns undef.
sub peth_port_ifindex {
my $peth = shift;
my $partial = shift;
my $peth_port_status = $peth->peth_port_status($partial);
my $peth_port_ifindex;
foreach my $i ( keys %$peth_port_status ) {
my ( $module, $port ) = split( /\./, $i );
if ( $module != 1 ) {
# This heuristic won't work, so say that we got nothing.
# If you have this case, you have to write a device-specific
# version of this function.
return;
}
$peth_port_ifindex->{$i} = $port;
}
return $peth_port_ifindex;
}
# Subclasses are encouraged to override this method to report
# what has actually been negotiated with the device, if a
# protocol with more values (e.g., CDP) has been used.
sub peth_port_neg_power {
my $peth = shift;
my $partial = shift;
my $peth_port_status = $peth->peth_port_status($partial);
my $peth_port_class = $peth->peth_port_class($partial);
my $poemax = { 'class0' => 12950, 'class1' => 3840, 'class2' => 6490, 'class3' => 12950,
'class4' => 25500 };
my $peth_port_neg_power = {};
foreach my $i ( keys %$peth_port_status ) {
if ($peth_port_status->{$i} eq 'deliveringPower') {
$peth_port_neg_power->{$i} = $poemax->{ $peth_port_class->{$i} };
}
}
return $peth_port_neg_power;
}
1;
__END__
=head1 NAME
SNMP::Info::PowerEthernet - SNMP Interface to data stored in
F<POWER-ETHERNET-MIB>.
=head1 AUTHOR
Bill Fenner
=head1 SYNOPSIS
# Let SNMP::Info determine the correct subclass for you.
my $poe = new SNMP::Info(
AutoSpecify => 1,
Debug => 1,
DestHost => 'myswitch',
Community => 'public',
Version => 2
)
or die "Can't connect to DestHost.\n";
my $class = $poe->class();
print "SNMP::Info determined this device to fall under subclass : $class\n";
=head1 DESCRIPTION
F<POWER-ETHERNET-MIB> is used to describe PoE (IEEE 802.3af)
Create or use a device subclass that inherit this class. Do not use directly.
For debugging purposes you can call this class directly as you would
SNMP::Info
my $poe = new SNMP::Info::PowerEthernet (...);
=head2 Inherited Classes
none.
=head2 Required MIBs
=over
=item F<POWER-ETHERNET-MIB>
=back
=head1 GLOBALS
none.
=head1 TABLE METHODS
These are methods that return tables of information in the form of a reference
to a hash.
=head2 Power Port Table
Selected values from the C<pethPsePortTable>
=over
=item $poe->peth_port_admin()
Administrative status: is this port permitted to deliver power?
C<pethPsePortAdminEnable>
=item $poe->peth_port_status()
Current status: is this port delivering power, searching, disabled, etc?
C<pethPsePortDetectionStatus>
=item $poe->peth_port_class()
Device class: if status is delivering power, this represents the 802.3af
class of the device being powered.
C<pethPsePortPowerClassifications>
=item $poe->peth_port_ifindex()
A mapping function from the C<pethPsePortTable> INDEX of
module.port to an C<ifIndex>. The default mapping ignores the
module (returning undef if there are any module values greater
than 1) and returns the port number, assuming that there is a
1:1 mapping.
This mapping is more or less left up to the device vendor to
implement; the MIB gives only very weak guidance.
A given device class may implement its own version
of this function (e.g., see Info::CiscoPower).
=item $poe->peth_port_neg_power()
The power, in milliwatts, that has been committed to this port.
This value is derived from the 802.3af class of the device being
powered, but may be overridden by a subclass that has information
from another source (e.g., if a different protocol, such as CDP,
was used to negotiate the power level.)
=back
=head2 Power Supply Table
=over
=item $poe->peth_power_watts()
The power supply's capacity, in watts.
C<pethMainPsePower>
=item $poe->peth_power_status()
The power supply's operational status.
C<pethMainPseOperStatus>
=item $poe->peth_power_consumption()
How much power, in watts, this power supply has been committed to
deliver. (Note: certain devices seem to supply this value in milliwatts,
so be cautious interpreting it.)
C<pethMainPseConsumptionPower>
=item $poe->peth_power_threshold()
The threshold (in percent) of consumption required to raise an
alarm.
C<pethMainPseUsageThreshold>
=back
=cut
|