1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 | #FULLNAME: Dell OpenManage
#VERSION: 1.0
#DESCRIPTION: Dell OpenManage is a set of systems management applications built using industry standard protocols and specifications. The rules included here were developed using an unknown version of Dell Open Management Server Administrator.
#####
#
# Copyright (C) 2004 G Ramon Gomez <gene at gomezbrothers dot com>
# All Rights Reserved
#
# This file is part of the Prelude-LML program.
#
# This program is free software; you can redistribute it and/or modify
# it under the terms of the GNU General Public License as published by
# the Free Software Foundation; either version 2, or (at your option)
# any later version.
#
# This program is distributed in the hope that it will be useful,
# but WITHOUT ANY WARRANTY; without even the implied warranty of
# MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
# GNU General Public License for more details.
#
# You should have received a copy of the GNU General Public License along
# with this program; if not, write to the Free Software Foundation, Inc.,
# 51 Franklin Street, Fifth Floor, Boston, MA 02110-1301 USA.
#
#####
#DESCRIPTION:Redundancy failure
#CATEGORY:Monitoring
#LOG:Jun 8 18:12:44 12.34.56.78 server administrator[warning] 1306 Redundancy lost Redundancy unit: System Power Unit Chassis location: Main System Chassis Previous redundancy state was: FULL Number of devices required for full redundancy: 2
regex=1306 Redundancy lost Redundancy unit: (.+?) Chassis location: (.+?) Previous redundancy state was: (.+?) Number of devices required for full redundancy: (\d+); \
classification.text=Redundancy failure; \
classification.reference(0).origin=vendor-specific; \
classification.reference(0).meaning=om_id; \
classification.reference(0).name=1306; \
classification.reference(0).url=http://support.dell.com/support/edocs/software/svradmin/1.9/en/messages/msgch20.htm; \
id=3800; \
revision=2; \
analyzer(0).name=OpenManage; \
analyzer(0).manufacturer=Dell; \
analyzer(0).class=State Monitoring; \
assessment.impact.severity=high; \
assessment.impact.completion=succeeded; \
assessment.impact.type=other; \
assessment.impact.description=Dell OpenManage has detected a loss of device redundancy in $1; \
additional_data(0).type=string; \
additional_data(0).meaning=Source device; \
additional_data(0).data=$1; \
additional_data(1).type=string; \
additional_data(1).meaning=Chassis location; \
additional_data(1).data=$2; \
additional_data(2).type=string; \
additional_data(2).meaning=Previous state; \
additional_data(2).data=$3; \
additional_data(3).type=integer; \
additional_data(3).meaning=Required devices; \
additional_data(3).data=$4; \
last
#DESCRIPTION:Power supply normal
#CATEGORY:Monitoring
#LOG:Jun 24 08:56:25 neo server administrator[info] 1352 Power supply returned to normal Sensor location: Power supply 2 Chassis location: Main System Chassis Previous state was: Critical (Failed)
regex=1352 Power supply returned to normal Sensor location: (.+?) Chassis location: (.+?) Previous state was: (.+); \
classification.text=Power supply normal; \
classification.reference(0).origin=vendor-specific; \
classification.reference(0).meaning=om_id; \
classification.reference(0).name=1352; \
classification.reference(0).url=http://support.dell.com/support/edocs/software/svradmin/1.9/en/messages/msgch20.htm; \
id=3801; \
revision=2; \
analyzer(0).name=OpenManage; \
analyzer(0).manufacturer=Dell; \
analyzer(0).class=State Monitoring; \
assessment.impact.severity=low; \
assessment.impact.completion=succeeded; \
assessment.impact.type=other; \
assessment.impact.description=$1 status returned to normal; \
additional_data(0).type=string; \
additional_data(0).meaning=Source device; \
additional_data(0).data=$1; \
additional_data(1).type=string; \
additional_data(1).meaning=Chassis location; \
additional_data(1).data=$2; \
additional_data(2).type=string; \
additional_data(2).meaning=Previous state; \
additional_data(2).data=$3; \
last
#DESCRIPTION:Power supply warning
#CATEGORY:Monitoring
#LOG:Jun 8 18:12:44 12.34.56.78 server administrator[warning] 1353 Power supply detected a warning Sensor location: Power supply 1 Chassis location: Main System Chassis Previous state was: OK (Normal) Power supply fan has failed
regex=1353 Power supply detected a warning Sensor location: (.+?) Chassis location: (.+?) Previous state was: (\w+ \(\w+\)|Unknown) (.+); \
classification.text=Power supply warning; \
classification.reference(0).origin=vendor-specific; \
classification.reference(0).meaning=om_id; \
classification.reference(0).name=1353; \
classification.reference(0).url=http://support.dell.com/support/edocs/software/svradmin/1.9/en/messages/msgch20.htm; \
id=3802; \
revision=2; \
analyzer(0).name=OpenManage; \
analyzer(0).manufacturer=Dell; \
analyzer(0).class=State Monitoring; \
assessment.impact.severity=medium; \
assessment.impact.completion=succeeded; \
assessment.impact.type=other; \
assessment.impact.description=$1 is in warning state, $4; \
additional_data(0).type=string; \
additional_data(0).meaning=Source device; \
additional_data(0).data=$1; \
additional_data(1).type=string; \
additional_data(1).meaning=Chassis location; \
additional_data(1).data=$2; \
additional_data(2).type=string; \
additional_data(2).meaning=Previous state; \
additional_data(2).data=$3; \
additional_data(3).type=string; \
additional_data(3).meaning=Event description; \
additional_data(3).data=$4; \
last
#DESCRIPTION:Power supply failure
#CATEGORY:Monitoring
#LOG:Jun 24 08:46:30 neo server administrator[error] 1354 Power supply detected a failure Sensor location: Power supply 2 Chassis location: Main System Chassis Previous state was: OK (Normal) Power supply input AC is off Power supply POK signal is not normal Power supply is turned off
regex=1354 Power supply detected a failure Sensor location: (.+?) Chassis location: (.+?) Previous state was: (\w+ \(\w+\)|Unknown) (.+); \
classification.text=Power supply failure; \
classification.reference(0).origin=vendor-specific; \
classification.reference(0).meaning=om_id; \
classification.reference(0).name=1354; \
classification.reference(0).url=http://support.dell.com/support/edocs/software/svradmin/1.9/en/messages/msgch20.htm; \
id=3803; \
revision=2; \
analyzer(0).name=OpenManage; \
analyzer(0).manufacturer=Dell; \
analyzer(0).class=State Monitoring; \
assessment.impact.severity=low; \
assessment.impact.completion=succeeded; \
assessment.impact.type=other; \
assessment.impact.description=$1 is in failure state, $4; \
additional_data(0).type=string; \
additional_data(0).meaning=Source device; \
additional_data(0).data=$1; \
additional_data(1).type=string; \
additional_data(1).meaning=Chassis location; \
additional_data(1).data=$2; \
additional_data(2).type=string; \
additional_data(2).meaning=Previous state; \
additional_data(2).data=$3; \
additional_data(3).type=string; \
additional_data(3).meaning=Event description; \
additional_data(3).data=$4; \
last
|