This file is indexed.

/etc/prelude-lml/ruleset/dell-om.rules is in prelude-lml-rules 4.1.0-1.

This file is owned by root:root, with mode 0o644.

The actual contents of the file can be viewed below.

  1
  2
  3
  4
  5
  6
  7
  8
  9
 10
 11
 12
 13
 14
 15
 16
 17
 18
 19
 20
 21
 22
 23
 24
 25
 26
 27
 28
 29
 30
 31
 32
 33
 34
 35
 36
 37
 38
 39
 40
 41
 42
 43
 44
 45
 46
 47
 48
 49
 50
 51
 52
 53
 54
 55
 56
 57
 58
 59
 60
 61
 62
 63
 64
 65
 66
 67
 68
 69
 70
 71
 72
 73
 74
 75
 76
 77
 78
 79
 80
 81
 82
 83
 84
 85
 86
 87
 88
 89
 90
 91
 92
 93
 94
 95
 96
 97
 98
 99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
#FULLNAME: Dell OpenManage
#VERSION: 1.0
#DESCRIPTION: Dell OpenManage is a set of systems management applications built using industry standard protocols and specifications. The rules included here were developed using an unknown version of Dell Open Management Server Administrator.

#####
#
# Copyright (C) 2004 G Ramon Gomez <gene at gomezbrothers dot com>
# All Rights Reserved
#
# This file is part of the Prelude-LML program.
#
# This program is free software; you can redistribute it and/or modify
# it under the terms of the GNU General Public License as published by
# the Free Software Foundation; either version 2, or (at your option)
# any later version.
#
# This program is distributed in the hope that it will be useful,
# but WITHOUT ANY WARRANTY; without even the implied warranty of
# MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.  See the
# GNU General Public License for more details.
#
# You should have received a copy of the GNU General Public License along
# with this program; if not, write to the Free Software Foundation, Inc.,
# 51 Franklin Street, Fifth Floor, Boston, MA 02110-1301 USA.
#
#####

#DESCRIPTION:Redundancy failure
#CATEGORY:Monitoring
#LOG:Jun  8 18:12:44 12.34.56.78 server administrator[warning] 1306  Redundancy lost Redundancy unit: System Power Unit Chassis location: Main System Chassis Previous redundancy state was: FULL Number of devices required for full redundancy: 2
regex=1306  Redundancy lost Redundancy unit: (.+?) Chassis location: (.+?) Previous redundancy state was: (.+?) Number of devices required for full redundancy: (\d+); \
 classification.text=Redundancy failure; \
 classification.reference(0).origin=vendor-specific; \
 classification.reference(0).meaning=om_id; \
 classification.reference(0).name=1306; \
 classification.reference(0).url=http://support.dell.com/support/edocs/software/svradmin/1.9/en/messages/msgch20.htm; \
 id=3800; \
 revision=2; \
 analyzer(0).name=OpenManage; \
 analyzer(0).manufacturer=Dell; \
 analyzer(0).class=State Monitoring; \
 assessment.impact.severity=high; \
 assessment.impact.completion=succeeded; \
 assessment.impact.type=other; \
 assessment.impact.description=Dell OpenManage has detected a loss of device redundancy in $1; \
 additional_data(0).type=string; \
 additional_data(0).meaning=Source device; \
 additional_data(0).data=$1; \
 additional_data(1).type=string; \
 additional_data(1).meaning=Chassis location; \
 additional_data(1).data=$2; \
 additional_data(2).type=string; \
 additional_data(2).meaning=Previous state; \
 additional_data(2).data=$3; \
 additional_data(3).type=integer; \
 additional_data(3).meaning=Required devices; \
 additional_data(3).data=$4; \
 last

#DESCRIPTION:Power supply normal
#CATEGORY:Monitoring
#LOG:Jun 24 08:56:25 neo server administrator[info] 1352  Power supply returned to normal Sensor location: Power supply 2 Chassis location: Main System Chassis Previous state was: Critical (Failed)
regex=1352  Power supply returned to normal Sensor location: (.+?) Chassis location: (.+?) Previous state was: (.+); \
 classification.text=Power supply normal; \
 classification.reference(0).origin=vendor-specific; \
 classification.reference(0).meaning=om_id; \
 classification.reference(0).name=1352; \
 classification.reference(0).url=http://support.dell.com/support/edocs/software/svradmin/1.9/en/messages/msgch20.htm; \
 id=3801; \
 revision=2; \
 analyzer(0).name=OpenManage; \
 analyzer(0).manufacturer=Dell; \
 analyzer(0).class=State Monitoring; \
 assessment.impact.severity=low; \
 assessment.impact.completion=succeeded; \
 assessment.impact.type=other; \
 assessment.impact.description=$1 status returned to normal; \
 additional_data(0).type=string; \
 additional_data(0).meaning=Source device; \
 additional_data(0).data=$1; \
 additional_data(1).type=string; \
 additional_data(1).meaning=Chassis location; \
 additional_data(1).data=$2; \
 additional_data(2).type=string; \
 additional_data(2).meaning=Previous state; \
 additional_data(2).data=$3; \
 last

#DESCRIPTION:Power supply warning
#CATEGORY:Monitoring
#LOG:Jun  8 18:12:44 12.34.56.78 server administrator[warning] 1353  Power supply detected a warning Sensor location: Power supply 1 Chassis location: Main System Chassis Previous state was: OK (Normal) Power supply fan has failed
regex=1353  Power supply detected a warning Sensor location: (.+?) Chassis location: (.+?) Previous state was: (\w+ \(\w+\)|Unknown) (.+); \
 classification.text=Power supply warning; \
 classification.reference(0).origin=vendor-specific; \
 classification.reference(0).meaning=om_id; \
 classification.reference(0).name=1353; \
 classification.reference(0).url=http://support.dell.com/support/edocs/software/svradmin/1.9/en/messages/msgch20.htm; \
 id=3802; \
 revision=2; \
 analyzer(0).name=OpenManage; \
 analyzer(0).manufacturer=Dell; \
 analyzer(0).class=State Monitoring; \
 assessment.impact.severity=medium; \
 assessment.impact.completion=succeeded; \
 assessment.impact.type=other; \
 assessment.impact.description=$1 is in warning state, $4; \
 additional_data(0).type=string; \
 additional_data(0).meaning=Source device; \
 additional_data(0).data=$1; \
 additional_data(1).type=string; \
 additional_data(1).meaning=Chassis location; \
 additional_data(1).data=$2; \
 additional_data(2).type=string; \
 additional_data(2).meaning=Previous state; \
 additional_data(2).data=$3; \
 additional_data(3).type=string; \
 additional_data(3).meaning=Event description; \
 additional_data(3).data=$4; \
 last

#DESCRIPTION:Power supply failure
#CATEGORY:Monitoring
#LOG:Jun 24 08:46:30 neo server administrator[error] 1354  Power supply detected a failure Sensor location: Power supply 2 Chassis location: Main System Chassis Previous state was: OK (Normal) Power supply input AC is off Power supply POK signal is not normal Power supply is turned off
regex=1354  Power supply detected a failure Sensor location: (.+?) Chassis location: (.+?) Previous state was: (\w+ \(\w+\)|Unknown) (.+); \
 classification.text=Power supply failure; \
 classification.reference(0).origin=vendor-specific; \
 classification.reference(0).meaning=om_id; \
 classification.reference(0).name=1354; \
 classification.reference(0).url=http://support.dell.com/support/edocs/software/svradmin/1.9/en/messages/msgch20.htm; \
 id=3803; \
 revision=2; \
 analyzer(0).name=OpenManage; \
 analyzer(0).manufacturer=Dell; \
 analyzer(0).class=State Monitoring; \
 assessment.impact.severity=low; \
 assessment.impact.completion=succeeded; \
 assessment.impact.type=other; \
 assessment.impact.description=$1 is in failure state, $4; \
 additional_data(0).type=string; \
 additional_data(0).meaning=Source device; \
 additional_data(0).data=$1; \
 additional_data(1).type=string; \
 additional_data(1).meaning=Chassis location; \
 additional_data(1).data=$2; \
 additional_data(2).type=string; \
 additional_data(2).meaning=Previous state; \
 additional_data(2).data=$3; \
 additional_data(3).type=string; \
 additional_data(3).meaning=Event description; \
 additional_data(3).data=$4; \
 last