/usr/share/config.kcfg/qalculatebackend.kcfg is in cantor-backend-qalculate 4:17.12.3-0ubuntu1.
This file is owned by root:root, with mode 0o644.
The actual contents of the file can be viewed below.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 | <?xml version="1.0" encoding="UTF-8"?>
<kcfg xmlns="http://www.kde.org/standards/kcfg/1.0"
xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
xsi:schemaLocation="http://www.kde.org/standards/kcfg/1.0
http://www.kde.org/standards/kcfg/1.0/kcfg.xsd" >
<kcfgfile name="cantorrc"/>
<group name="QalculateBackend">
<entry name="postConversion" type="bool">
<label>If and how units will be automatically converted. If true, convert to the best suited SI units (the least amount of units).</label>
<default>true</default>
</entry>
<entry name="angleUnit" type="Enum">
<label>Default angle unit for trigonometric functions.</label>
<choices name="AngleUnit">
<choice name="ANGLE_UNIT_NONE" />
<choice name="ANGLE_UNIT_RADIANS" />
<choice name="ANGLE_UNIT_DEGREES" />
<choice name="ANGLE_UNIT_GRADIANS" />
</choices>
<default>1</default>
</entry>
<entry name="base" type="int">
<label>Base of parsed and evaluated numbers.</label>
<default>10</default>
</entry>
<entry name="structuring" type="Enum">
<choices name="StructuringMode">
<choice name="STRUCTURING_NONE" />
<choice name="STRUCTURING_SIMPLIFY" />
<choice name="STRUCTURING_FACTORIZE" />
</choices>
<label>If the evaluation result will be simplified or factorized.</label>
<default>0</default>
</entry>
<entry name="fractionFormat" type="Enum">
<choices name="NumberFractionFormat">
<choice name="FRACTION_DECIMAL" />
<choice name="FRACTION_DECIMAL_EXACT" />
<choice name="FRACTION_FRACTIONAL" />
<choice name="FRACTION_COMBINED" />
</choices>
<label>If rational numbers will be displayed with decimals, as a fraction, or something in between.</label>
<default>0</default>
</entry>
<entry name="indicateInfiniteSeries" type="bool">
<label>Show that the digit series of a number continues forever with three dots, instead of rounding (ex. 2/3 displays as 0.666666... instead of 0.666667).</label>
<default>false</default>
</entry>
<entry name="useAllPrefixes" type="bool">
<label>Use all decimal SI prefixes. If false, prefixes which is not a multiple of thousand (centi, deci, deca, hecto) will not be used automatically.</label>
<default>false</default>
</entry>
<entry name="negativeExponents" type="bool">
<label>If true, negative exponents will be used instead of division (ex. 5/x^2 becomes 5*x^-2).</label>
<default>false</default>
</entry>
<entry name="minExp" type="Enum">
<choices name="ExpMode">
<choice name="EXP_NONE" />
<choice name="EXP_PURE" />
<choice name="EXP_SCIENTIFIC" />
<choice name="EXP_PRECISION" />
</choices>
<label>Numerical display.</label>
<default>3</default>
</entry>
<entry name="inlinePlot" type="bool">
<label>If true, plots will be displayed inside the worksheet. If not they appear in a separate window.</label>
<default>true</default>
</entry>
<entry name="coloredPlot" type="bool">
<label>Whether colors should be used in plots.</label>
<default>true</default>
</entry>
<entry name="plotGrid" type="bool">
<label>Whether a grid should be plotted.</label>
<default>false</default>
</entry>
<entry name="plotBorder" type="bool">
<label>Whether full borders should be drawn around the plot.</label>
<default>false</default>
</entry>
<entry name="plotLineWidth" type="int">
<label>Width of lines, in pixels.</label>
<default>2</default>
</entry>
<entry name="plotSteps" type="int">
<label>Number of interpolation steps to be used in plotting.</label>
<default>100</default>
</entry>
<entry name="plotSmoothing" type="Enum">
<choices name="SmoothingMode">
<choice name="SMOOTHING_NONE" />
<choice name="SMOOTHING_UNIQUE" />
<choice name="SMOOTHING_CSPLINES" />
<choice name="SMOOTHING_BEZIER" />
<choice name="SMOOTHING_SBEZIER" />
</choices>
<label>Smoothing mode in plots.</label>
<default>0</default>
</entry>
<entry name="plotStyle" type="Enum">
<choices name="PlotStyle">
<choice name="STYLE_LINES" />
<choice name="STYLE_POINTS" />
<choice name="STYLE_LINES_POINTS" />
<choice name="STYLE_BOXES" />
<choice name="STYLE_HISTOGRAM" />
<choice name="STYLE_STEPS" />
<choice name="STYLE_CANDLESTICKS" />
<choice name="STYLE_DOTS" />
</choices>
<label>Style of plots.</label>
<default>0</default>
</entry>
<entry name="plotLegend" type="Enum">
<choices name="LegendPosition">
<choice name="LEGEND_NONE" />
<choice name="LEGEND_TOP_LEFT" />
<choice name="LEGEND_TOP_RIGHT" />
<choice name="LEGEND_BOTTOM_LEFT" />
<choice name="LEGEND_BOTTOM_RIGHT" />
<choice name="LEGEND_BELOW" />
<choice name="LEGEND_OUTSIDE" />
</choices>
<label>Legend position in plots.</label>
<default>2</default>
</entry>
<entry name="autorunScripts" type="StringList">
<label>List of scripts to autorun at the beginning of session</label>
</entry>
</group>
</kcfg>
|