This file is indexed.

/usr/sbin/fence_lpar is in fence-agents 4.0.25-2ubuntu1.

This file is owned by root:root, with mode 0o755.

The actual contents of the file can be viewed below.

  1
  2
  3
  4
  5
  6
  7
  8
  9
 10
 11
 12
 13
 14
 15
 16
 17
 18
 19
 20
 21
 22
 23
 24
 25
 26
 27
 28
 29
 30
 31
 32
 33
 34
 35
 36
 37
 38
 39
 40
 41
 42
 43
 44
 45
 46
 47
 48
 49
 50
 51
 52
 53
 54
 55
 56
 57
 58
 59
 60
 61
 62
 63
 64
 65
 66
 67
 68
 69
 70
 71
 72
 73
 74
 75
 76
 77
 78
 79
 80
 81
 82
 83
 84
 85
 86
 87
 88
 89
 90
 91
 92
 93
 94
 95
 96
 97
 98
 99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
#!/usr/bin/python -tt

#####
##
## The Following Agent Has Been Tested On:
##
##  Version
## +---------------------------------------------+
##  Tested on HMC
##
#####

import sys, re
import atexit
sys.path.append("/usr/share/fence")
from fencing import *
from fencing import fail, fail_usage, EC_STATUS_HMC

#BEGIN_VERSION_GENERATION
RELEASE_VERSION="4.0.25"
BUILD_DATE="(built Sat, 10 Feb 2018 00:55:27 -0800)"
REDHAT_COPYRIGHT="Copyright (C) Red Hat, Inc. 2004-2010 All rights reserved."
#END_VERSION_GENERATION

def get_power_status(conn, options):
	if options["--hmc-version"] == "3":
		conn.send("lssyscfg -r lpar -m " + options["--managed"] + " -n " + options["--plug"] + " -F name,state\n")
		conn.log_expect(options["--command-prompt"], int(options["--power-timeout"]))

		try:
			status = re.compile("^" + options["--plug"] + ",(.*?),.*$",
					re.IGNORECASE | re.MULTILINE).search(conn.before).group(1)
		except AttributeError:
			fail(EC_STATUS_HMC)
	elif options["--hmc-version"] in ["4", "IVM"]:
		conn.send("lssyscfg -r lpar -m "+ options["--managed"] +
				" --filter 'lpar_names=" + options["--plug"] + "'\n")
		conn.log_expect(options["--command-prompt"], int(options["--power-timeout"]))

		try:
			status = re.compile(",state=(.*?),", re.IGNORECASE).search(conn.before).group(1)
		except AttributeError:
			fail(EC_STATUS_HMC)

	##
	## Transformation to standard ON/OFF status if possible
	if status in ["Running", "Open Firmware", "Shutting Down", "Starting"]:
		status = "on"
	else:
		status = "off"

	return status

def set_power_status(conn, options):
	if options["--hmc-version"] == "3":
		conn.send("chsysstate -o " + options["--action"] + " -r lpar -m " + options["--managed"]
			+ " -n " + options["--plug"] + "\n")
		conn.log_expect(options["--command-prompt"], int(options["--power-timeout"]))
	elif options["--hmc-version"] in ["4", "IVM"]:
		if options["--action"] == "on":
			conn.send("chsysstate -o on -r lpar -m " + options["--managed"] +
				" -n " + options["--plug"] +
				" -f `lssyscfg -r lpar -F curr_profile " +
				" -m " + options["--managed"] +
				" --filter \"lpar_names=" + options["--plug"] + "\"`\n")
		else:
			conn.send("chsysstate -o shutdown -r lpar --immed" +
				" -m " + options["--managed"] + " -n " + options["--plug"] + "\n")
		conn.log_expect(options["--command-prompt"], int(options["--power-timeout"]))

def get_lpar_list(conn, options):
	outlets = {}
	if options["--hmc-version"] == "3":
		conn.send("query_partition_names -m " + options["--managed"] + "\n")
		conn.log_expect(options["--command-prompt"], int(options["--power-timeout"]))

		## We have to remove first 3 lines (command + header) and last line (part of new prompt)
		####
		res = re.search("^.+?\n(.+?\n){2}(.*)\n.*$", conn.before, re.S)

		if res == None:
			fail_usage("Unable to parse output of list command")

		lines = res.group(2).split("\n")
		for outlet_line in lines:
			outlets[outlet_line.rstrip()] = ("", "")
	elif options["--hmc-version"] == "4":
		conn.send("lssyscfg -r lpar -m " + options["--managed"] +
			" -F name:state\n")
		conn.log_expect(options["--command-prompt"], int(options["--power-timeout"]))

		## We have to remove first line (command) and last line (part of new prompt)
		####
		res = re.search("^.+?\n(.*)\n.*$", conn.before, re.S)

		if res == None:
			fail_usage("Unable to parse output of list command")

		lines = res.group(1).split("\n")
		for outlet_line in lines:
			try:
				(port, status) = outlet_line.split(":")
			except ValueError:
				fail_usage('Output does not match expected HMC version, try different one');
			outlets[port] = ("", status)
	elif options["--hmc-version"] == "IVM":
		conn.send("lssyscfg -r lpar -m " + options["--managed"] +
			" -F name,state\n")
		conn.log_expect(options["--command-prompt"], int(options["--power-timeout"]))

		## We have to remove first line (command) and last line (part of new prompt)
		####
		res = re.search("^.+?\n(.*)\n.*$", conn.before, re.S)

		if res == None:
			fail_usage("Unable to parse output of list command")

		lines = res.group(1).split("\n")
		for outlet_line in lines:
			try:
				(port, status) = outlet_line.split(",")
			except ValueError:
				fail_usage('Output does not match expected HMC version, try different one');
			outlets[port] = ("", status)

	return outlets

def define_new_opts():
	all_opt["managed"] = {
		"getopt" : "s:",
		"longopt" : "managed",
		"help" : "-s, --managed=[id]             Name of the managed system",
		"required" : "0",
		"shortdesc" : "Managed system name",
		"order" : 1}
	all_opt["hmc_version"] = {
		"getopt" : "H:",
		"longopt" : "hmc-version",
		"help" : "-H, --hmc-version=[version]    Force HMC version to use: (3|4|ivm) (default: 4)",
		"required" : "0",
		"shortdesc" : "Force HMC version to use",
		"default" : "4",
		"choices" : ["3", "4", "ivm"],
		"order" : 1}

def main():
	device_opt = ["ipaddr", "login", "passwd", "secure", "cmd_prompt", \
	                "port", "managed", "hmc_version"]

	atexit.register(atexit_handler)

	define_new_opts()

	all_opt["login_timeout"]["default"] = "15"
	all_opt["secure"]["default"] = "1"
	all_opt["cmd_prompt"]["default"] = [r":~>", r"]\$", r"\$ "]

	options = check_input(device_opt, process_input(device_opt), other_conditions = True)

	docs = {}
	docs["shortdesc"] = "Fence agent for IBM LPAR"
	docs["longdesc"] = ""
	docs["vendorurl"] = "http://www.ibm.com"
	show_docs(options, docs)

	if "--managed" not in options:
		fail_usage("Failed: You have to enter name of managed system")

	if options["--action"] == "validate-all":
		sys.exit(0)

	##
	## Operate the fencing device
	####
	conn = fence_login(options)
	result = fence_action(conn, options, set_power_status, get_power_status, get_lpar_list)
	fence_logout(conn, "quit\r\n")
	sys.exit(result)

if __name__ == "__main__":
	main()