/var/spool/hylafax/config/att-dataport is in hylafax-server 3:6.0.6-8.
This file is owned by root:root, with mode 0o644.
The actual contents of the file can be viewed below.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 | # $Id$
#
# HylaFAX Facsimile Software
#
# Copyright (c) 1990-1996 Sam Leffler
# Copyright (c) 1991-1996 Silicon Graphics, Inc.
# HylaFAX is a trademark of Silicon Graphics, Inc.
#
# Permission to use, copy, modify, distribute, and sell this software and
# its documentation for any purpose is hereby granted without fee, provided
# that (i) the above copyright notices and this permission notice appear in
# all copies of the software and related documentation, and (ii) the names of
# Sam Leffler and Silicon Graphics may not be used in any advertising or
# publicity relating to the software without the specific, prior written
# permission of Sam Leffler and Silicon Graphics.
#
# THE SOFTWARE IS PROVIDED "AS-IS" AND WITHOUT WARRANTY OF ANY KIND,
# EXPRESS, IMPLIED OR OTHERWISE, INCLUDING WITHOUT LIMITATION, ANY
# WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
#
# IN NO EVENT SHALL SAM LEFFLER OR SILICON GRAPHICS BE LIABLE FOR
# ANY SPECIAL, INCIDENTAL, INDIRECT OR CONSEQUENTIAL DAMAGES OF ANY KIND,
# OR ANY DAMAGES WHATSOEVER RESULTING FROM LOSS OF USE, DATA OR PROFITS,
# WHETHER OR NOT ADVISED OF THE POSSIBILITY OF DAMAGE, AND ON ANY THEORY OF
# LIABILITY, ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE
# OF THIS SOFTWARE.
#
#
# Configuration for using the Class 1 command interface with
# an AT&T DataPort 14.4 modem. Firmware version 122 (ati1)
# or newer.
#
# Hardware flow control is used by default.
#
# Note that due to a bug in the 1.22 firmware the FCS bytes in the HDLC
# frames are NOT returned to the host. This is fixed in versions 1.33
# and later. To deal with this problem, early firmware revs should be
# sure to have Class1FrameOverhead set to 2 instead of the normal 4.
#
# CONFIG:CLASS1:144:.*:.*: Manufacturer='AT&T' Model=Dataport
#
# BEGIN-SERVER
# END-SERVER
#
# Modem-related stuff: should reflect modem command interface
# and hardware connection/cabling (e.g. flow control).
#
ModemType: Class1 # use class 1 interface
ModemRate: 19200
ModemFlowControl: rtscts # default
#
ModemHardFlowCmd: AT&R0\D1\Q3 # use RTS/CTS and enable RS232 handling
ModemSoftFlowCmd: AT&R1\D0\Q1 # use RTS/CTS and enable RS232 handling
ModemSetupDTRCmd: AT&D2 # setup so DTR drop resets modem
ModemSetupDCDCmd: AT&C1 # setup so DCD follows carrier
ModemSetupAACmd: AT+FAA=0 # disable in case of Class 2 support
#
ModemMfrQueryCmd: !AT&T
ModemModelQueryCmd: !DataPort
ModemRevQueryCmd: ATI19
#
# NB: this works around a bug in the 1.22 firmware; it is fixed
# in versions 1.33 and later in which case you can remove this
# line and use the default value of 4 (though leaving it as 2
# won't harm anything).
#
Class1FrameOverhead: 2 # 1.22 firmware does not include FCS
#
# The modem returns "OK" when there is a timeout before carrier is
# established. This is treated as "NO CARRIER" by faxd. Thus we
# need to up the NoCarrierRetrys parameter to avoid having the server
# reject jobs prematurely.
#
NoCarrierRetrys: 3 # retry 3 times on no carrier
#
PagerSetupCmds: ATS41=10%B300 # use V.21 at 300 bps
|