# $Id$
#
# HylaFAX Facsimile Software
#
# Copyright (c) 1990-1996 Sam Leffler
# Copyright (c) 1991-1996 Silicon Graphics, Inc.
# HylaFAX is a trademark of Silicon Graphics, Inc.
# 
# Permission to use, copy, modify, distribute, and sell this software and 
# its documentation for any purpose is hereby granted without fee, provided
# that (i) the above copyright notices and this permission notice appear in
# all copies of the software and related documentation, and (ii) the names of
# Sam Leffler and Silicon Graphics may not be used in any advertising or
# publicity relating to the software without the specific, prior written
# permission of Sam Leffler and Silicon Graphics.
# 
# THE SOFTWARE IS PROVIDED "AS-IS" AND WITHOUT WARRANTY OF ANY KIND, 
# EXPRESS, IMPLIED OR OTHERWISE, INCLUDING WITHOUT LIMITATION, ANY 
# WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.  
# 
# IN NO EVENT SHALL SAM LEFFLER OR SILICON GRAPHICS BE LIABLE FOR
# ANY SPECIAL, INCIDENTAL, INDIRECT OR CONSEQUENTIAL DAMAGES OF ANY KIND,
# OR ANY DAMAGES WHATSOEVER RESULTING FROM LOSS OF USE, DATA OR PROFITS,
# WHETHER OR NOT ADVISED OF THE POSSIBILITY OF DAMAGE, AND ON ANY THEORY OF 
# LIABILITY, ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE 
# OF THIS SOFTWARE.
#

#
# Configuration for an Everex 24/96D.
#
# It may be possible to run the modem using RTS/CTS, but at the
# data rates it supports there's little point (and since everything
# works fine with XON/XOFF flow control, little motivation).
#
# CONFIG: CLASS2: Everex*-XONXOFF
# CONFIG: CLASS2: Everex*-DEFAULT
#
# BEGIN-SERVER
# END-SERVER
#
# Modem-related stuff: should reflect modem command interface
# and hardware connection/cabling (e.g. flow control).
#
ModemType:		Class2		# use class 2 interface
ModemRate:		19200
ModemFlowControl:	xonxoff		# default
#
ModemSetupDTRCmd:	AT&D3		# DTR off causes modem to reset
ModemSetupDCDCmd:	AT&C0		# DCD always on
ModemDialCmd:		ATDT%s		# T for tone dialing
#
# Avoid BOR_C_REV 'cuz of a bug in the Everex modem firmware
# (Rev 901231 or earlier): BOR=3 and REL=1 generates garbage
# data in the EOL padding for received facsimile.
#
Class2BORCmd:		AT+FBOR=2	# direct phase C data, reversed B/D
Class2RELCmd:		AT+FREL=1	# enable byte-aligned EOLs
#
# NB: must break CQ=1 BADMUL= BADLIN= into separate lines
#     for the modem to grok
#
Class2CQCmd:		"AT+FCQ=1\nAT+FBADMUL=20\nAT+FBADLIN=10"
#
# Disable 2D-encoded data 'cuz some PROM versions appear
# to receive bad data (if you figure out why, then remove this).
#
Class2DCCQueryCmd:      !(0,1),(0-3),(0-2),(0-2),(0),(0),(0),(0-7)