/var/spool/hylafax/config/telebit-wb is in hylafax-server 3:6.0.6-8.
This file is owned by root:root, with mode 0o644.
The actual contents of the file can be viewed below.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 | # $Id$
#
# HylaFAX Facsimile Software
#
# Copyright (c) 1990-1996 Sam Leffler
# Copyright (c) 1991-1996 Silicon Graphics, Inc.
# HylaFAX is a trademark of Silicon Graphics, Inc.
#
# Permission to use, copy, modify, distribute, and sell this software and
# its documentation for any purpose is hereby granted without fee, provided
# that (i) the above copyright notices and this permission notice appear in
# all copies of the software and related documentation, and (ii) the names of
# Sam Leffler and Silicon Graphics may not be used in any advertising or
# publicity relating to the software without the specific, prior written
# permission of Sam Leffler and Silicon Graphics.
#
# THE SOFTWARE IS PROVIDED "AS-IS" AND WITHOUT WARRANTY OF ANY KIND,
# EXPRESS, IMPLIED OR OTHERWISE, INCLUDING WITHOUT LIMITATION, ANY
# WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
#
# IN NO EVENT SHALL SAM LEFFLER OR SILICON GRAPHICS BE LIABLE FOR
# ANY SPECIAL, INCIDENTAL, INDIRECT OR CONSEQUENTIAL DAMAGES OF ANY KIND,
# OR ANY DAMAGES WHATSOEVER RESULTING FROM LOSS OF USE, DATA OR PROFITS,
# WHETHER OR NOT ADVISED OF THE POSSIBILITY OF DAMAGE, AND ON ANY THEORY OF
# LIABILITY, ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE
# OF THIS SOFTWARE.
#
#
# Configuration for a Telebit WorldBlazer modem with rev LA7.01
# or newer firmware. Note that adaptive answer is only available
# with firmware rev 7.20.
#
# The modem is setup to run at 38.4 for both sending and receiving
# and RTS/CTS flow control is used by default.
#
# CONFIG: CLASS2: Telebit*-*
# CONFIG: CLASS2: TELEBIT*-*
#
# BEGIN-SERVER
# END-SERVER
#
# Modem-related stuff: should reflect modem command interface
# and hardware connection/cabling (e.g. flow control).
#
ModemType: Class2 # use class 2 interface
ModemRate: 19200 # rate for DCE-DTE communication
ModemFlowControl: rtscts # default
#
ModemHardFlowCmd: ATS58=2 # full duplex hardware flow control
ModemSoftFlowCmd: ATS58=3 # XON/XOFF flow control
ModemSetupDTRCmd: AT&D3 # setup so DTR drop resets modem
ModemSetupDCDCmd: AT&C1 # setup so DCD reflects carrier (or not)
#
ModemSetupAACmd: AT+FAA=1;+FCLASS=0 # enable in class 2 & reset to data
ModemWaitForConnect: yes # two-part protocol for adaptive-answer
#
ModemResetDelay: 3200 # extra long reset timeout required
#
ModemSendFillOrder: LSB2MSB # as expected
ModemRecvFillOrder: MSB2LSB # opposite of what makes sense
#
Class2DDISCmd: AT+FDIS # LA7.20N apparently requires this
|