/var/lib/pcp/testsuite/800.out is in pcp-testsuite 4.0.1-1.
This file is owned by root:root, with mode 0o644.
The actual contents of the file can be viewed below.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 | QA output created by 800
=== Hotproc disabled by default test ===
dbpmda> open pipe PCP_PMDAS_DIR/proc/pmdaproc -d 3
Start pmdaproc PMDA: PCP_PMDAS_DIR/proc/pmdaproc -d 3
dbpmda> getdesc on
dbpmda> fetch hotproc.control.config_gen
PMID(s): 3.NUMBER.NUMBER
pmResult dump from ADDR timestamp: 0.000000 TIME numpmid: 1
3.NUMBER.NUMBER (hotproc.control.config_gen): numval: 1 valfmt: 0 vlist[]:
value 0
dbpmda> fetch hotproc.control.config
PMID(s): 3.NUMBER.NUMBER
pmResult dump from ADDR timestamp: 0.000000 TIME numpmid: 1
3.NUMBER.NUMBER (hotproc.control.config): numval: 1 valfmt: 1 vlist[]:
value ""
dbpmda>
=== Check that hotproc can have interval set early===
dbpmda> open pipe PCP_PMDAS_DIR/proc/pmdaproc -d 3
Start pmdaproc PMDA: PCP_PMDAS_DIR/proc/pmdaproc -d 3
dbpmda> getdesc on
dbpmda> attr "username" "root"
Attribute: username=root
Success
dbpmda> attr 11 "0"
Attribute: userid=0
Success
dbpmda> store hotproc.control.refresh "1"
PMID: 3.NUMBER.NUMBER
Getting description...
Sending Profile...
Getting Result Structure...
3.NUMBER.NUMBER: 10 -> 1
Sending Result...
dbpmda> wait 3
dbpmda> fetch hotproc.nprocs
PMID(s): 3.NUMBER.NUMBER
pmResult dump from ADDR timestamp: 0.000000 TIME numpmid: 1
3.NUMBER.NUMBER (hotproc.nprocs): numval: 1 valfmt: 0 vlist[]:
value 0
dbpmda>
=== Check that hotproc can be configured with UID===
dbpmda> open pipe PCP_PMDAS_DIR/proc/pmdaproc -d 3
Start pmdaproc PMDA: PCP_PMDAS_DIR/proc/pmdaproc -d 3
dbpmda> getdesc on
dbpmda> attr "username" "root"
Attribute: username=root
Success
dbpmda> attr 11 "0"
Attribute: userid=0
Success
dbpmda> store hotproc.control.config "uid==0"
PMID: 3.NUMBER.NUMBER
Getting description...
Sending Profile...
Getting Result Structure...
3.NUMBER.NUMBER: "" -> "uid==0"
Sending Result...
dbpmda> store hotproc.control.refresh "1"
PMID: 3.NUMBER.NUMBER
Getting description...
Getting Result Structure...
3.NUMBER.NUMBER: 10 -> 1
Sending Result...
dbpmda> fetch hotproc.control.config
PMID(s): 3.NUMBER.NUMBER
pmResult dump from ADDR timestamp: 0.000000 TIME numpmid: 1
3.NUMBER.NUMBER (hotproc.control.config): numval: 1 valfmt: 1 vlist[]:
value "(uid == 0)"
dbpmda> wait 3
dbpmda> fetch hotproc.nprocs
PMID(s): 3.NUMBER.NUMBER
pmResult dump from ADDR timestamp: 0.000000 TIME numpmid: 1
3.NUMBER.NUMBER (hotproc.nprocs): numval: 1 valfmt: 0 vlist[]:
value NUMBER
dbpmda>
=== Check that hotproc can be configured with process name===
dbpmda> open pipe PCP_PMDAS_DIR/proc/pmdaproc -d 3
Start pmdaproc PMDA: PCP_PMDAS_DIR/proc/pmdaproc -d 3
dbpmda> getdesc on
dbpmda> attr "username" "root"
Attribute: username=root
Success
dbpmda> attr 11 "0"
Attribute: userid=0
Success
dbpmda> store hotproc.control.config 'fname=="pmdaproc"'
PMID: 3.NUMBER.NUMBER
Getting description...
Sending Profile...
Getting Result Structure...
3.NUMBER.NUMBER: "" -> "fname=="pmdaproc""
Sending Result...
dbpmda> store hotproc.control.refresh "1"
PMID: 3.NUMBER.NUMBER
Getting description...
Getting Result Structure...
3.NUMBER.NUMBER: 10 -> 1
Sending Result...
dbpmda> wait 3
dbpmda> fetch hotproc.nprocs
PMID(s): 3.NUMBER.NUMBER
pmResult dump from ADDR timestamp: 0.000000 TIME numpmid: 1
3.NUMBER.NUMBER (hotproc.nprocs): numval: 1 valfmt: 0 vlist[]:
value NUMBER
dbpmda>
|