This file is indexed.

/var/lib/pcp/testsuite/967.out is in pcp-testsuite 4.0.1-1.

This file is owned by root:root, with mode 0o644.

The actual contents of the file can be viewed below.

  1
  2
  3
  4
  5
  6
  7
  8
  9
 10
 11
 12
 13
 14
 15
 16
 17
 18
 19
 20
 21
 22
 23
 24
 25
 26
 27
 28
 29
 30
 31
 32
 33
 34
 35
 36
 37
 38
 39
 40
 41
 42
 43
 44
 45
 46
 47
 48
 49
 50
 51
 52
 53
 54
 55
 56
 57
 58
 59
 60
 61
 62
 63
 64
 65
 66
 67
 68
 69
 70
 71
 72
 73
 74
 75
 76
 77
 78
 79
 80
 81
 82
 83
 84
 85
 86
 87
 88
 89
 90
 91
 92
 93
 94
 95
 96
 97
 98
 99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
QA output created by 967
=== Daemon PMDA papi auto_enable disabled test ===
dbpmda> open pipe PCP_PMDAS_DIR/papi/pmdapapi -d 126 -l TMP.log
Start pmdapapi PMDA: PCP_PMDAS_DIR/papi/pmdapapi -d 126 -l TMP.log
dbpmda> getdesc on
dbpmda> attr 'username' 'root'
Attribute: username=root
Success
dbpmda> attr 11 '0'
Attribute: userid=0
Success
dbpmda> desc papi.system.TOT_INS
PMID: 126.0.NUMBER
    Data Type: 64-bit int  InDom: PM_INDOM_NULL ADDR
    Semantics: counter  Units: count
dbpmda> desc papi.control.status
PMID: 126.1.3
    Data Type: string  InDom: PM_INDOM_NULL ADDR
    Semantics: instant  Units: none
dbpmda> desc papi.control.auto_enable
PMID: 126.1.4
    Data Type: 32-bit unsigned int  InDom: PM_INDOM_NULL ADDR
    Semantics: discrete  Units: sec
dbpmda> store papi.control.auto_enable "0"
PMID: 126.1.4
Getting description...
Sending Profile...
Getting Result Structure...
126.1.4: 120 -> 0
Sending Result...
dbpmda> fetch papi.system.TOT_INS
PMID(s): 126.0.NUMBER
pmResult dump from ADDR timestamp: 0.000000 TIME numpmid: 1
  126.0.NUMBER (<noname>): No values returned!
dbpmda> store papi.control.enable "TOT_INS"
PMID: 126.1.0
Getting description...
Getting Result Structure...
126.1.0: "" -> "TOT_INS"
Sending Result...
dbpmda> fetch papi.system.TOT_INS
PMID(s): 126.0.NUMBER
pmResult dump from ADDR timestamp: 0.000000 TIME numpmid: 1
  126.0.NUMBER (<noname>): numval: 1 valfmt: 1 vlist[]:
   value NUMBER
dbpmda> store papi.control.disable "TOT_INS"
PMID: 126.1.2
Getting description...
Getting Result Structure...
126.1.2: "" -> "TOT_INS"
Sending Result...
dbpmda> fetch papi.system.TOT_INS
PMID(s): 126.0.NUMBER
pmResult dump from ADDR timestamp: 0.000000 TIME numpmid: 1
  126.0.NUMBER (<noname>): No values returned!
dbpmda> 
=== Daemon PMDA papi auto_enable test ===
dbpmda> open pipe PCP_PMDAS_DIR/papi/pmdapapi -d 126 -l TMP.log
Start pmdapapi PMDA: PCP_PMDAS_DIR/papi/pmdapapi -d 126 -l TMP.log
dbpmda> getdesc on
dbpmda> attr "username" "root"
Attribute: username=root
Success
dbpmda> attr 11 "0"
Attribute: userid=0
Success
dbpmda> desc papi.system.TOT_INS
PMID: 126.0.NUMBER
    Data Type: 64-bit int  InDom: PM_INDOM_NULL ADDR
    Semantics: counter  Units: count
dbpmda> store papi.control.auto_enable "5"
PMID: 126.1.4
Getting description...
Sending Profile...
Getting Result Structure...
126.1.4: 120 -> 5
Sending Result...
dbpmda> fetch papi.system.TOT_INS
PMID(s): 126.0.NUMBER
pmResult dump from ADDR timestamp: 0.000000 TIME numpmid: 1
  126.0.NUMBER (<noname>): numval: 1 valfmt: 1 vlist[]:
   value NUMBER
dbpmda> fetch papi.control.status
PMID(s): 126.1.3
pmResult dump from ADDR timestamp: 0.000000 TIME numpmid: 1
  126.1.3 (papi.control.status): numval: 1 valfmt: 1 vlist[]:
   value "Papi is running, has multiplexing enabled, TOT_INS(5) NUMBER"
dbpmda> wait 7
dbpmda> fetch papi.control.status
PMID(s): 126.1.3
pmResult dump from ADDR timestamp: 0.000000 TIME numpmid: 1
  126.1.3 (papi.control.status): numval: 1 valfmt: 1 vlist[]:
   value "Papi is stopped, has multiplexing enabled, "
dbpmda> 
=== Daemon PMDA papi auto_enable with papi.control.enable test ===
dbpmda> open pipe PCP_PMDAS_DIR/papi/pmdapapi -d 126 -l TMP.log
Start pmdapapi PMDA: PCP_PMDAS_DIR/papi/pmdapapi -d 126 -l TMP.log
dbpmda> getdesc on
dbpmda> attr "username" "root"
Attribute: username=root
Success
dbpmda> attr 11 "0"
Attribute: userid=0
Success
dbpmda> desc papi.system.TOT_INS
PMID: 126.0.NUMBER
    Data Type: 64-bit int  InDom: PM_INDOM_NULL ADDR
    Semantics: counter  Units: count
dbpmda> store papi.control.auto_enable "5"
PMID: 126.1.4
Getting description...
Sending Profile...
Getting Result Structure...
126.1.4: 120 -> 5
Sending Result...
dbpmda> store papi.control.enable "TOT_INS"
PMID: 126.1.0
Getting description...
Getting Result Structure...
126.1.0: "" -> "TOT_INS"
Sending Result...
dbpmda> fetch papi.system.TOT_INS
PMID(s): 126.0.NUMBER
pmResult dump from ADDR timestamp: 0.000000 TIME numpmid: 1
  126.0.NUMBER (<noname>): numval: 1 valfmt: 1 vlist[]:
   value NUMBER
dbpmda> fetch papi.control.status
PMID(s): 126.1.3
pmResult dump from ADDR timestamp: 0.000000 TIME numpmid: 1
  126.1.3 (papi.control.status): numval: 1 valfmt: 1 vlist[]:
   value "Papi is running, has multiplexing enabled, TOT_INS(-1) NUMBER"
dbpmda> wait 7
dbpmda> fetch papi.control.status
PMID(s): 126.1.3
pmResult dump from ADDR timestamp: 0.000000 TIME numpmid: 1
  126.1.3 (papi.control.status): numval: 1 valfmt: 1 vlist[]:
   value "Papi is running, has multiplexing enabled, TOT_INS(-1) NUMBER"
dbpmda> store papi.control.disable "TOT_INS"
PMID: 126.1.2
Getting description...
Getting Result Structure...
126.1.2: "" -> "TOT_INS"
Sending Result...
dbpmda> fetch papi.control.status
PMID(s): 126.1.3
pmResult dump from ADDR timestamp: 0.000000 TIME numpmid: 1
  126.1.3 (papi.control.status): numval: 1 valfmt: 1 vlist[]:
   value "Papi is stopped, has multiplexing enabled, "
dbpmda> 
=== Daemon PMDA papi auto_enable with multiplexing disabled test ===
dbpmda> open pipe PCP_PMDAS_DIR/papi/pmdapapi -d 126 -l TMP.log
Start pmdapapi PMDA: PCP_PMDAS_DIR/papi/pmdapapi -d 126 -l TMP.log
dbpmda> getdesc on
dbpmda> attr "username" "root"
Attribute: username=root
Success
dbpmda> attr 11 "0"
Attribute: userid=0
Success
dbpmda> desc papi.control.multiplex
PMID: 126.1.5
    Data Type: 32-bit unsigned int  InDom: PM_INDOM_NULL ADDR
    Semantics: discrete  Units: none
dbpmda> fetch papi.control.status
PMID(s): 126.1.3
pmResult dump from ADDR timestamp: 0.000000 TIME numpmid: 1
  126.1.3 (papi.control.status): numval: 1 valfmt: 1 vlist[]:
   value "Papi is stopped, has multiplexing enabled, "
dbpmda> store papi.control.multiplex "0"
PMID: 126.1.5
Getting description...
Getting Result Structure...
126.1.5: 1 -> 0
Sending Result...
dbpmda> store papi.control.auto_enable "5"
PMID: 126.1.4
Getting description...
Getting Result Structure...
126.1.4: 120 -> 5
Sending Result...
dbpmda> fetch papi.system.TOT_INS
PMID(s): 126.0.NUMBER
pmResult dump from ADDR timestamp: 0.000000 TIME numpmid: 1
  126.0.NUMBER (<noname>): numval: 1 valfmt: 1 vlist[]:
   value NUMBER
dbpmda> fetch papi.control.status
PMID(s): 126.1.3
pmResult dump from ADDR timestamp: 0.000000 TIME numpmid: 1
  126.1.3 (papi.control.status): numval: 1 valfmt: 1 vlist[]:
   value "Papi is running, TOT_INS(5) NUMBER"
dbpmda> wait 7
dbpmda> fetch papi.control.status
PMID(s): 126.1.3
pmResult dump from ADDR timestamp: 0.000000 TIME numpmid: 1
  126.1.3 (papi.control.status): numval: 1 valfmt: 1 vlist[]:
   value "Papi is stopped, "
dbpmda>