This file is indexed.

/usr/share/ElmerGUI/edf-extra/reynolds.xml is in elmer-common 6.1.0.svn.5396.dfsg-2ubuntu1.

This file is owned by root:root, with mode 0o644.

The actual contents of the file can be viewed below.

  1
  2
  3
  4
  5
  6
  7
  8
  9
 10
 11
 12
 13
 14
 15
 16
 17
 18
 19
 20
 21
 22
 23
 24
 25
 26
 27
 28
 29
 30
 31
 32
 33
 34
 35
 36
 37
 38
 39
 40
 41
 42
 43
 44
 45
 46
 47
 48
 49
 50
 51
 52
 53
 54
 55
 56
 57
 58
 59
 60
 61
 62
 63
 64
 65
 66
 67
 68
 69
 70
 71
 72
 73
 74
 75
 76
 77
 78
 79
 80
 81
 82
 83
 84
 85
 86
 87
 88
 89
 90
 91
 92
 93
 94
 95
 96
 97
 98
 99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
<?xml version='1.0' encoding='UTF-8'?>
<!DOCTYPE edf>
<edf version="1.0" >
   <PDE Name="Reynolds Equation" >
      <Name>Reynolds Equation</Name>

      <Equation>
         <Parameter Widget="Label" > <Name> Local velocity settings </Name> </Parameter>
         <Parameter Widget="Edit" >
            <Name> Normal Velocity </Name>
         </Parameter>
         <Parameter Widget="Edit" >
            <Name> Tangent Velocity 1 </Name>
         </Parameter>
         <Parameter Widget="Edit" >
            <Name> Tangent Velocity 2 </Name>
         </Parameter>
         <Parameter Widget="Edit" >
            <Name> Tangent Velocity 3 </Name>
         </Parameter>

         <Parameter Widget="Label" > <Name> Global velocity settings </Name> </Parameter>
         <Parameter Widget="Edit" >
            <Name> Surface Velocity 1 </Name>
         </Parameter>
         <Parameter Widget="Edit" >
            <Name> Surface Velocity 2 </Name>
         </Parameter>
         <Parameter Widget="Edit" >
            <Name> Surface Velocity 3 </Name>
         </Parameter>


         <Parameter Widget="Label">
           <Name> Free text input </Name>
         </Parameter>
	 
	 <Parameter Widget="TextEdit" Enabled="True">
	   <Name> Free text </Name>
	   <Type> String </Type>
	   <Whatis> Free text is copied into the Equation-block of the SIF as such. </Whatis>
	   <StatusTip> Free text is copied into the Equation-block of the SIF as such. </StatusTip>
	 </Parameter>

      </Equation>

      <Solver>
         <Parameter Widget="Edit" >
            <Name > Procedure </Name>
            <DefaultValue> "ReynoldsSolver" "ReynoldsSolver" </DefaultValue>
         </Parameter>
         <Parameter Widget="Edit" Enabled="False">
           <Name> Variable </Name>
           <DefaultValue> FilmPressure </DefaultValue>
         </Parameter>
 
       <Parameter Widget="Label"> <Name>Definitions for cavitation</Name> </Parameter>

         <Parameter Widget="CheckBox">
           <Name> Apply Limiter </Name>
           <Whatis> If checked the pressure may be given a soft limit as in cavitation. </Whatis>
           <StatusTip> If checked the pressure may be given a soft limit as in cavitation. </StatusTip>
           <Activate> /Reynolds Equation/BodyForce/Filmpressure Lower Limit</Activate>
         </Parameter>

         <Parameter Widget="Label">
           <Name> Free text input </Name>
         </Parameter>	 
	 <Parameter Widget="TextEdit" Enabled="True">
	   <Name> Free text </Name>
	   <Type> String </Type>
	   <Whatis> Free text is copied into the Solver-block of the SIF as such. </Whatis>
	   <StatusTip> Free text is copied into the Solver-block of the SIF as such. </StatusTip>
	 </Parameter>
       </Solver>

      <InitialCondition>
         <Parameter Widget="Label" > <Name> Variables </Name> </Parameter>
          <Parameter  Widget="Edit">
           <Name> FilmPressure  </Name>
         </Parameter>
      </InitialCondition>

      <BodyForce>
         <Parameter Widget="Label" > <Name> Dirichlet Conditions - Cavitation</Name> </Parameter>
         <Parameter  Widget="Edit">
           <Name> FilmPressure  </Name>
           <Activate> /Reynolds Equation/BodyForce/FilmPressure Condition </Activate>
         </Parameter>

         <Parameter  Widget="Edit" Enabled="False">
           <Name> FilmPressure Condition </Name>
         </Parameter>

         <Parameter  Widget="Edit" Enabled="False">
           <Name> Filmpressure Lower Limit </Name>
           <Whatis> Soft limit for pressure that may be used to model cavitation</Whatis>
           <StatusTip> Soft limit for pressure that may be used to model cavitation</StatusTip>
         </Parameter>

         <Parameter Widget="Label">
           <Name> Free text input </Name>
         </Parameter>
	 
	 <Parameter Widget="TextEdit" Enabled="True">
	   <Name> Free text </Name>
	   <Type> String </Type>
	   <Whatis> Free text is copied into the Body Force-block of the SIF as such. </Whatis>
	   <StatusTip> Free text is copied into the Body Force-block of the SIF as such. </StatusTip>
	 </Parameter>

      </BodyForce>

      <Material>
         <Parameter Widget="Label" > <Name> Properties of gap</Name> </Parameter>

         <Parameter Widget="Edit" >
            <Name> Gap Height </Name>
         </Parameter>

         <Parameter Widget="Edit" >
            <Name> Flow Admittance </Name>
         </Parameter>


        <Parameter Widget="Label" > <Name> Material properties </Name> </Parameter>

         <Parameter Widget="Edit" >
            <Name> Viscosity </Name>
         </Parameter>

         <Parameter Widget="Combo">
            <Name>Viscosity Model</Name>
            <Type>String </Type>
            <Whatis> The newtionian and rarafied viscosity models. </Whatis>
            <Item> <Name> None </Name> </Item>
            <Item> <Name> Newtonian </Name></Item>
            <Item> <Name> Rarefied </Name>
              <Activate> /Reynolds Equation/Material/Mean Free Path</Activate>
            </Item>
          </Parameter>  

         <Parameter Widget="Edit"  Enabled="False" Visible="False">
            <Name> Mean Free Path  </Name>
         </Parameter>


         <Parameter Widget="Combo" >
            <Name> Compressibility Model </Name>
           <Type>String </Type>
            <Whatis> The incompressible or compressible models. </Whatis>
            <Item> <Name> None </Name> </Item>
            <Item> <Name> Incompressible </Name></Item>
             <Item> <Name> Weakly compressible </Name>
             <Activate> /Reynolds Equation/Material/Bulk Modulus</Activate>
             </Item>
             <Item> <Name> Isothermal ideal gas </Name>
              <Activate> /Reynolds Equation/Material/Reference Pressure</Activate>
             </Item>
            <Item> <Name> Adiabatic ideal gas </Name>
              <Activate> /Reynolds Equation/Material/Reference Pressure</Activate>
             <Activate> /Reynolds Equation/Material/Specific Heat Ratio</Activate>
            </Item>
         </Parameter>

         <Parameter Widget="Edit"  Enabled="False" Visible="False">
            <Name> Reference Pressure </Name>
         </Parameter>

         <Parameter Widget="Edit"  Enabled="False" Visible="False">
            <Name> Specific Heat Ratio </Name>
         </Parameter>

         <Parameter Widget="Edit"  Enabled="False" Visible="False">
            <Name> Bulk Modulus </Name>
         </Parameter>

         <Parameter Widget="Label">
           <Name> Free text input </Name>
         </Parameter>
	 
	 <Parameter Widget="TextEdit" Enabled="True">
	   <Name> Free text </Name>
	   <Type> String </Type>
	   <Whatis> Free text is copied into the Material-block of the SIF as such. </Whatis>
	   <StatusTip> Free text is copied into the Material-block of the SIF as such. </StatusTip>
	 </Parameter>

      </Material>


      <InitialCondition>
         <Parameter Widget="Label" > <Name> Variables </Name> </Parameter>
         <Parameter  Widget="Edit">
           <Name> FilmPressure </Name>
         </Parameter>

         <Parameter Widget="Label">
           <Name> Free text input </Name>
         </Parameter>
	 
	 <Parameter Widget="TextEdit" Enabled="True">
	   <Name> Free text </Name>
	   <Type> String </Type>
	   <Whatis> Free text is copied into the Initial Condition-block of the SIF as such. </Whatis>
	   <StatusTip> Free text is copied into the Initial Condition-block of the SIF as such. </StatusTip>
	 </Parameter>


      </InitialCondition>

      <BoundaryCondition>
         <Parameter Widget="Label" > <Name> Dirichlet Conditions </Name> </Parameter>
         <Parameter  Widget="Edit">
           <Name> FilmPressure  </Name>
           <Activate> /Reynolds Equation/BoundaryCondition/FilmPressure Condition </Activate>
         </Parameter>

         <Parameter  Widget="Edit" Enabled="False">
           <Name> FilmPressure Condition </Name>
           <Whatis> If the given value is less than zero, apply flux condition insted of the Dirichlet Condition. To be generally useful space and/or time varying values may be given. </Whatis>
           <StatusTip> Give FilmPressure condition value for this boundary. </StatusTip>
         </Parameter>

         <Parameter Widget="Label" > <Name> Effective Elongation </Name> </Parameter>
         <Parameter Widget="CheckBox">
           <Name> Open Side </Name>
           <Whatis> If checked use effective elongation model for the side. </Whatis>
         </Parameter>

          <Parameter Widget="Label"> <Name> Periodic boundary condition </Name> </Parameter>
          <Parameter Widget="CheckBox">
              <Name> Filmpressure periodic </Name>
              <SifName> Periodic BC Filmpressure </SifName>
          </Parameter>

         <Parameter Widget="Label">
           <Name> Free text input </Name>
         </Parameter>
	 
	 <Parameter Widget="TextEdit" Enabled="True">
	   <Name> Free text </Name>
	   <Type> String </Type>
	   <Whatis> Free text is copied into the Boundary Condition-block of the SIF as such. </Whatis>
	   <StatusTip> Free text is copied into the Boundary Condition-block of the SIF as such. </StatusTip>
	 </Parameter>

      </BoundaryCondition>
   </PDE>
</edf>