/usr/share/ElmerGUI/edf-extra/reynolds.xml is in elmer-common 6.1.0.svn.5396.dfsg-2ubuntu1.
This file is owned by root:root, with mode 0o644.
The actual contents of the file can be viewed below.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 | <?xml version='1.0' encoding='UTF-8'?>
<!DOCTYPE edf>
<edf version="1.0" >
<PDE Name="Reynolds Equation" >
<Name>Reynolds Equation</Name>
<Equation>
<Parameter Widget="Label" > <Name> Local velocity settings </Name> </Parameter>
<Parameter Widget="Edit" >
<Name> Normal Velocity </Name>
</Parameter>
<Parameter Widget="Edit" >
<Name> Tangent Velocity 1 </Name>
</Parameter>
<Parameter Widget="Edit" >
<Name> Tangent Velocity 2 </Name>
</Parameter>
<Parameter Widget="Edit" >
<Name> Tangent Velocity 3 </Name>
</Parameter>
<Parameter Widget="Label" > <Name> Global velocity settings </Name> </Parameter>
<Parameter Widget="Edit" >
<Name> Surface Velocity 1 </Name>
</Parameter>
<Parameter Widget="Edit" >
<Name> Surface Velocity 2 </Name>
</Parameter>
<Parameter Widget="Edit" >
<Name> Surface Velocity 3 </Name>
</Parameter>
<Parameter Widget="Label">
<Name> Free text input </Name>
</Parameter>
<Parameter Widget="TextEdit" Enabled="True">
<Name> Free text </Name>
<Type> String </Type>
<Whatis> Free text is copied into the Equation-block of the SIF as such. </Whatis>
<StatusTip> Free text is copied into the Equation-block of the SIF as such. </StatusTip>
</Parameter>
</Equation>
<Solver>
<Parameter Widget="Edit" >
<Name > Procedure </Name>
<DefaultValue> "ReynoldsSolver" "ReynoldsSolver" </DefaultValue>
</Parameter>
<Parameter Widget="Edit" Enabled="False">
<Name> Variable </Name>
<DefaultValue> FilmPressure </DefaultValue>
</Parameter>
<Parameter Widget="Label"> <Name>Definitions for cavitation</Name> </Parameter>
<Parameter Widget="CheckBox">
<Name> Apply Limiter </Name>
<Whatis> If checked the pressure may be given a soft limit as in cavitation. </Whatis>
<StatusTip> If checked the pressure may be given a soft limit as in cavitation. </StatusTip>
<Activate> /Reynolds Equation/BodyForce/Filmpressure Lower Limit</Activate>
</Parameter>
<Parameter Widget="Label">
<Name> Free text input </Name>
</Parameter>
<Parameter Widget="TextEdit" Enabled="True">
<Name> Free text </Name>
<Type> String </Type>
<Whatis> Free text is copied into the Solver-block of the SIF as such. </Whatis>
<StatusTip> Free text is copied into the Solver-block of the SIF as such. </StatusTip>
</Parameter>
</Solver>
<InitialCondition>
<Parameter Widget="Label" > <Name> Variables </Name> </Parameter>
<Parameter Widget="Edit">
<Name> FilmPressure </Name>
</Parameter>
</InitialCondition>
<BodyForce>
<Parameter Widget="Label" > <Name> Dirichlet Conditions - Cavitation</Name> </Parameter>
<Parameter Widget="Edit">
<Name> FilmPressure </Name>
<Activate> /Reynolds Equation/BodyForce/FilmPressure Condition </Activate>
</Parameter>
<Parameter Widget="Edit" Enabled="False">
<Name> FilmPressure Condition </Name>
</Parameter>
<Parameter Widget="Edit" Enabled="False">
<Name> Filmpressure Lower Limit </Name>
<Whatis> Soft limit for pressure that may be used to model cavitation</Whatis>
<StatusTip> Soft limit for pressure that may be used to model cavitation</StatusTip>
</Parameter>
<Parameter Widget="Label">
<Name> Free text input </Name>
</Parameter>
<Parameter Widget="TextEdit" Enabled="True">
<Name> Free text </Name>
<Type> String </Type>
<Whatis> Free text is copied into the Body Force-block of the SIF as such. </Whatis>
<StatusTip> Free text is copied into the Body Force-block of the SIF as such. </StatusTip>
</Parameter>
</BodyForce>
<Material>
<Parameter Widget="Label" > <Name> Properties of gap</Name> </Parameter>
<Parameter Widget="Edit" >
<Name> Gap Height </Name>
</Parameter>
<Parameter Widget="Edit" >
<Name> Flow Admittance </Name>
</Parameter>
<Parameter Widget="Label" > <Name> Material properties </Name> </Parameter>
<Parameter Widget="Edit" >
<Name> Viscosity </Name>
</Parameter>
<Parameter Widget="Combo">
<Name>Viscosity Model</Name>
<Type>String </Type>
<Whatis> The newtionian and rarafied viscosity models. </Whatis>
<Item> <Name> None </Name> </Item>
<Item> <Name> Newtonian </Name></Item>
<Item> <Name> Rarefied </Name>
<Activate> /Reynolds Equation/Material/Mean Free Path</Activate>
</Item>
</Parameter>
<Parameter Widget="Edit" Enabled="False" Visible="False">
<Name> Mean Free Path </Name>
</Parameter>
<Parameter Widget="Combo" >
<Name> Compressibility Model </Name>
<Type>String </Type>
<Whatis> The incompressible or compressible models. </Whatis>
<Item> <Name> None </Name> </Item>
<Item> <Name> Incompressible </Name></Item>
<Item> <Name> Weakly compressible </Name>
<Activate> /Reynolds Equation/Material/Bulk Modulus</Activate>
</Item>
<Item> <Name> Isothermal ideal gas </Name>
<Activate> /Reynolds Equation/Material/Reference Pressure</Activate>
</Item>
<Item> <Name> Adiabatic ideal gas </Name>
<Activate> /Reynolds Equation/Material/Reference Pressure</Activate>
<Activate> /Reynolds Equation/Material/Specific Heat Ratio</Activate>
</Item>
</Parameter>
<Parameter Widget="Edit" Enabled="False" Visible="False">
<Name> Reference Pressure </Name>
</Parameter>
<Parameter Widget="Edit" Enabled="False" Visible="False">
<Name> Specific Heat Ratio </Name>
</Parameter>
<Parameter Widget="Edit" Enabled="False" Visible="False">
<Name> Bulk Modulus </Name>
</Parameter>
<Parameter Widget="Label">
<Name> Free text input </Name>
</Parameter>
<Parameter Widget="TextEdit" Enabled="True">
<Name> Free text </Name>
<Type> String </Type>
<Whatis> Free text is copied into the Material-block of the SIF as such. </Whatis>
<StatusTip> Free text is copied into the Material-block of the SIF as such. </StatusTip>
</Parameter>
</Material>
<InitialCondition>
<Parameter Widget="Label" > <Name> Variables </Name> </Parameter>
<Parameter Widget="Edit">
<Name> FilmPressure </Name>
</Parameter>
<Parameter Widget="Label">
<Name> Free text input </Name>
</Parameter>
<Parameter Widget="TextEdit" Enabled="True">
<Name> Free text </Name>
<Type> String </Type>
<Whatis> Free text is copied into the Initial Condition-block of the SIF as such. </Whatis>
<StatusTip> Free text is copied into the Initial Condition-block of the SIF as such. </StatusTip>
</Parameter>
</InitialCondition>
<BoundaryCondition>
<Parameter Widget="Label" > <Name> Dirichlet Conditions </Name> </Parameter>
<Parameter Widget="Edit">
<Name> FilmPressure </Name>
<Activate> /Reynolds Equation/BoundaryCondition/FilmPressure Condition </Activate>
</Parameter>
<Parameter Widget="Edit" Enabled="False">
<Name> FilmPressure Condition </Name>
<Whatis> If the given value is less than zero, apply flux condition insted of the Dirichlet Condition. To be generally useful space and/or time varying values may be given. </Whatis>
<StatusTip> Give FilmPressure condition value for this boundary. </StatusTip>
</Parameter>
<Parameter Widget="Label" > <Name> Effective Elongation </Name> </Parameter>
<Parameter Widget="CheckBox">
<Name> Open Side </Name>
<Whatis> If checked use effective elongation model for the side. </Whatis>
</Parameter>
<Parameter Widget="Label"> <Name> Periodic boundary condition </Name> </Parameter>
<Parameter Widget="CheckBox">
<Name> Filmpressure periodic </Name>
<SifName> Periodic BC Filmpressure </SifName>
</Parameter>
<Parameter Widget="Label">
<Name> Free text input </Name>
</Parameter>
<Parameter Widget="TextEdit" Enabled="True">
<Name> Free text </Name>
<Type> String </Type>
<Whatis> Free text is copied into the Boundary Condition-block of the SIF as such. </Whatis>
<StatusTip> Free text is copied into the Boundary Condition-block of the SIF as such. </StatusTip>
</Parameter>
</BoundaryCondition>
</PDE>
</edf>
|