This file is indexed.

/usr/share/perl5/SNMP/Info/SONMP.pm is in libsnmp-info-perl 2.06-1.

This file is owned by root:root, with mode 0o644.

The actual contents of the file can be viewed below.

  1
  2
  3
  4
  5
  6
  7
  8
  9
 10
 11
 12
 13
 14
 15
 16
 17
 18
 19
 20
 21
 22
 23
 24
 25
 26
 27
 28
 29
 30
 31
 32
 33
 34
 35
 36
 37
 38
 39
 40
 41
 42
 43
 44
 45
 46
 47
 48
 49
 50
 51
 52
 53
 54
 55
 56
 57
 58
 59
 60
 61
 62
 63
 64
 65
 66
 67
 68
 69
 70
 71
 72
 73
 74
 75
 76
 77
 78
 79
 80
 81
 82
 83
 84
 85
 86
 87
 88
 89
 90
 91
 92
 93
 94
 95
 96
 97
 98
 99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
# SNMP::Info::SONMP
# $Id$
#
# Copyright (c) 2008 Eric Miller
# All rights reserved.
#
# Redistribution and use in source and binary forms, with or without
# modification, are permitted provided that the following conditions are met:
#
#     * Redistributions of source code must retain the above copyright notice,
#       this list of conditions and the following disclaimer.
#     * Redistributions in binary form must reproduce the above copyright
#       notice, this list of conditions and the following disclaimer in the
#       documentation and/or other materials provided with the distribution.
#     * Neither the name of the University of California, Santa Cruz nor the
#       names of its contributors may be used to endorse or promote products
#       derived from this software without specific prior written permission.
#
# THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS"
# AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
# IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
# ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT OWNER OR CONTRIBUTORS BE
# LIABLE FOR # ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR
# CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF
# SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS
# INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN
# CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE)
# ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE
# POSSIBILITY OF SUCH DAMAGE.

package SNMP::Info::SONMP;

use strict;
use Exporter;
use SNMP::Info;

@SNMP::Info::SONMP::ISA       = qw/SNMP::Info Exporter/;
@SNMP::Info::SONMP::EXPORT_OK = qw//;

use vars qw/$VERSION %FUNCS %GLOBALS %MIBS %MUNGE/;

$VERSION = '2.06';

%MIBS = (
    'SYNOPTICS-ROOT-MIB'           => 'synoptics',
    'S5-ETH-MULTISEG-TOPOLOGY-MIB' => 's5EnMsTop',
);

%GLOBALS = (
    'cdp_id'  => 's5EnMsTopIpAddr',
    'cdp_run' => 's5EnMsTopStatus',
);

%FUNCS = (

    # From S5-ETH-MULTISEG-TOPOLOGY-MIB::TopNmmTable
    'sonmp_topo_slot'     => 's5EnMsTopNmmSlot',
    'sonmp_topo_port'     => 's5EnMsTopNmmPort',
    'sonmp_topo_ip'       => 's5EnMsTopNmmIpAddr',
    'sonmp_topo_seg'      => 's5EnMsTopNmmSegId',
    'sonmp_topo_mac'      => 's5EnMsTopNmmMacAddr',
    'sonmp_topo_platform' => 's5EnMsTopNmmChassisType',
    'sonmp_topo_localseg' => 's5EnMsTopNmmLocalSeg',
);

%MUNGE = ( 'sonmp_topo_mac' => \&SNMP::Info::munge_mac );

sub index_factor {
    return 32;
}

sub slot_offset {
    return 1;
}

sub port_offset {
    return 0;
}

sub hasCDP {
    my $sonmp = shift;
    return $sonmp->cdp_run();
}

sub c_if {
    my $sonmp   = shift;
    my $partial = shift;

    my $sonmp_topo_port = $sonmp->sonmp_topo_port($partial) || {};
    my $sonmp_topo_slot = $sonmp->sonmp_topo_slot($partial) || {};
    my $index_factor    = $sonmp->index_factor();
    my $slot_offset     = $sonmp->slot_offset();
    my $port_offset     = $sonmp->port_offset();
    my $model           = $sonmp->model();

    my %c_if;
    foreach my $entry ( keys %$sonmp_topo_port ) {
        my $port = $sonmp_topo_port->{$entry};
        next unless defined $port;
        next if $port == 0;
        my $slot = $sonmp_topo_slot->{$entry} || 0;

        if ( $model eq 'Baystack Hub' ) {
            my $comidx = $slot;
            if ( !( $comidx % 5 ) ) {
                $slot = ( $slot / 5 );
            }
            elsif ( $comidx =~ /[16]$/ ) {
                $slot = int( $slot / 5 );
                $port = 25;
            }
            elsif ( $comidx =~ /[27]$/ ) {
                $slot = int( $slot / 5 );
                $port = 26;
            }
        }

        my $index = ( ( $slot - $slot_offset ) * $index_factor )
            + ( $port - $port_offset );

        $c_if{$entry} = $index;
    }
    return \%c_if;
}

sub c_ip {
    my $sonmp   = shift;
    my $partial = shift;

    my $sonmp_topo_port = $sonmp->sonmp_topo_port($partial) || {};
    my $sonmp_topo_ip   = $sonmp->sonmp_topo_ip($partial)   || {};

    my %c_ip;
    foreach my $entry ( keys %$sonmp_topo_ip ) {
        my $port = $sonmp_topo_port->{$entry};
        next unless defined $port;
        next if $port == 0;

        my $ip = $sonmp_topo_ip->{$entry};
        $c_ip{$entry} = $ip;
    }
    return \%c_ip;
}

sub c_port {
    my $sonmp   = shift;
    my $partial = shift;

    my $sonmp_topo_port     = $sonmp->sonmp_topo_port($partial)     || {};
    my $sonmp_topo_seg      = $sonmp->sonmp_topo_seg($partial)      || {};
    my $sonmp_topo_platform = $sonmp->sonmp_topo_platform($partial) || {};

    my %c_port;
    foreach my $entry ( keys %$sonmp_topo_seg ) {
        my $port = $sonmp_topo_port->{$entry};
        next unless defined $port;
        next if $port == 0;

        my $seg      = $sonmp_topo_seg->{$entry};
        my $platform = $sonmp_topo_platform->{$entry};

        # AP-222x Series does not adhere to port numbering
        if ( $platform =~ /AccessPoint/i ) {
            $c_port{$entry} = 'dp0';
        }

        # BayHubs send the lower three bytes of the MAC not the slot/port
        elsif ( $seg > 4000 ) {
            $c_port{$entry} = 'unknown';
        }
        else {

            # Segment id is (256 * remote slot_num) + (remote_port)
            my $remote_port = $seg % 256;
            my $remote_slot = int( $seg / 256 );

            $c_port{$entry} = "$remote_slot.$remote_port";
        }
    }
    return \%c_port;
}

sub c_platform {
    my $sonmp   = shift;
    my $partial = shift;

    my $sonmp_topo_port     = $sonmp->sonmp_topo_port($partial)     || {};
    my $sonmp_topo_platform = $sonmp->sonmp_topo_platform($partial) || {};

    my %c_platform;
    foreach my $entry ( keys %$sonmp_topo_platform ) {
        my $port = $sonmp_topo_port->{$entry};
        next unless defined $port;
        next if $port == 0;

        my $platform = $sonmp_topo_platform->{$entry};

        $c_platform{$entry} = $platform;
    }
    return \%c_platform;
}

sub mac {
    my $sonmp = shift;

    my $sonmp_topo_port = $sonmp->sonmp_topo_port();
    my $sonmp_topo_mac  = $sonmp->sonmp_topo_mac();

    foreach my $entry ( keys %$sonmp_topo_port ) {
        my $port = $sonmp_topo_port->{$entry};
        next unless $port == 0;
        my $mac = $sonmp_topo_mac->{$entry};
        return $mac;
    }

    # Topology turned off, not supported.
    return;
}

1;
__END__

=head1 NAME

SNMP::Info::SONMP - SNMP Interface to SynOptics Network Management Protocol
(SONMP)

=head1 AUTHOR

Eric Miller

=head1 SYNOPSIS

 my $sonmp = new SNMP::Info ( 
                             AutoSpecify => 1,
                             Debug       => 1,
                             DestHost    => 'router', 
                             Community   => 'public',
                             Version     => 2
                           );

 my $class = $sonmp->class();
 print " Using device sub class : $class\n";

 $hascdp   = $sonmp->hasCDP() ? 'yes' : 'no';

 # Print out a map of device ports with CDP neighbors:
 my $interfaces = $sonmp->interfaces();
 my $c_if       = $sonmp->c_if();
 my $c_ip       = $sonmp->c_ip();
 my $c_port     = $sonmp->c_port();

 foreach my $cdp_key (keys %$c_ip){
    my $iid           = $c_if->{$cdp_key};
    my $port          = $interfaces->{$iid};
    my $neighbor      = $c_ip->{$cdp_key};
    my $neighbor_port = $c_port->{$cdp_key};
    print "Port : $port connected to $neighbor / $neighbor_port\n";
 }

=head1 DESCRIPTION

SNMP::Info::SONMP is a subclass of SNMP::Info that provides an object oriented 
interface to the SynOptics Network Management Protocol (SONMP) information
through SNMP.

SONMP is a Layer 2 protocol that supplies topology information of devices that
also speak SONMP, mostly switches and hubs.  SONMP is implemented in
SynOptics, Bay, and Nortel devices.  SONMP has been rebranded by Bay then
Nortel and is know by several different names, most recently Nortel
Discovery Protocol (NDP).

Create or use a device subclass that inherits this class.  Do not use
directly.

Each device implements a subset of the global and cache entries. 
Check the return value to see if that data is held by the device.

=head2 Inherited Classes

None.

=head2 Required MIBs

=over

=item F<SYNOPTICS-ROOT-MIB>

=item F<S5-ETH-MULTISEG-TOPOLOGY-MIB>

=back

=head1 GLOBAL METHODS

These are methods that return scalar values from SNMP

=over

=item  $sonmp->index_factor()

Returns a number representing the number of ports reserved per slot or switch
within the device MIB.  Defaults to 32.

=item $sonmp->slot_offset()

Returns the offset if slot numbering does not start at 0.  Defaults to 1.

=item $sonmp->port_offset()

Returns the offset if port numbering does not start at 0.  Defaults to 0. 

=item  $cdp->hasCDP()

Is SONMP is active in this device?

=item $sonmp->cdp_id()

Returns the IP that the device is sending out for its Nmm topology info.

(C<s5EnMsTopIpAddr>)

=item $sonmp->cdp_run()

Returns true if SONMP is on for this device. 

(C<s5EnMsTopStatus>)

=item $sonmp->mac()

Returns MAC of the advertised IP address of the device. 

=back

=head1 TABLE METHODS

These are methods that return tables of information in the form of a reference
to a hash.

=head2 Layer2 Topology info (C<s5EnMsTopNmmTable>)

=over

=item $sonmp->sonmp_topo_slot()

Returns reference to hash.  Key: Table entry, Value:slot number

(C<s5EnMsTopNmmSlot>)

=item $sonmp->sonmp_topo_port()

Returns reference to hash.  Key: Table entry, Value:Port Number
(interface iid)

(C<s5EnMsTopNmmPort>)

=item $sonmp->sonmp_topo_ip()

Returns reference to hash.  Key: Table entry, Value:Remote IP address of entry

(C<s5EnMsTopNmmIpAddr>)

=item $sonmp->sonmp_topo_seg()

Returns reference to hash.  Key: Table entry, Value:Remote Segment ID

(C<s5EnMsTopNmmSegId>)

=item $sonmp->sonmp_topo_mac()

(C<s5EnMsTopNmmMacAddr>)

Returns reference to hash.  Key: Table entry, Value:Remote MAC address

=item $sonmp->sonmp_topo_platform

Returns reference to hash.  Key: Table entry, Value:Remote Device Type

(C<s5EnMsTopNmmChassisType>)

=item $sonmp->sonmp_topo_localseg

Returns reference to hash.  Key: Table entry, Value: Boolean, if
bay_topo_seg() is local.

(C<s5EnMsTopNmmLocalSeg>)

=back

=head2 Pseudo CDP information

All entries with port=0 are local and ignored.

=over

=item $sonmp->c_if()

Returns reference to hash.  Key: IID, Value: Local port (interfaces)

=item $sonmp->c_ip()

Returns reference to hash.  Key: IID, Value: Remote IP address

If multiple entries exist with the same local port, c_if(), with different
IPv4 addresses, c_ip(), there is either a non SONMP device in between two or
more devices or multiple devices which are not directly connected.  

Use the data from the Layer2 Topology Table below to dig deeper.

=item $sonmp->c_port()

Returns reference to hash. Key: IID, Value: Remote port (interfaces)

=item $sonmp->c_platform()

Returns reference to hash. Key: IID, Value: Remote device type

=back

=cut