1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 | <component>
<!-- Note on logging configuration:
This schema component expects to use a section type named
"eventlog"; this type needs to be provided by some other
component that the top-level schema needs to import.
The import is not performed here to allow applications to
load the type from different components.
-->
<sectiontype name="runner">
<description>
This section describes the options for zdctl.py and zdrun.py.
The only required option is "program". Many other options have
no default value specified in the schema; in some cases, the
program calculates a dynamic default, in others, the feature
associated with the option is disabled.
For those options that also have corresponding command-line
options, the command line option (short and long form) are given
here too.
</description>
<section name="*" type="ZConfig.logger.log"
attribute="eventlog"
required="no">
<description>
Log configuration for zdctl.py and zdrun.py. These
applications will normally use the eventlog section at the top
level of the configuration, but will use this eventlog section
if it exists.
(This is done so that the combined schema for the runner and
the controlled application will write to the same logs by
default, but a separation of logs can be achieved if desired.)
</description>
</section>
<key name="program" datatype="string-list"
required="yes">
<description>
Command-line option: -p or --program (zdctl.py only).
This option gives the command used to start the subprocess
managed by zdrun.py. This is currently a simple list of
whitespace-delimited words. The first word is the program
file, subsequent words are its command line arguments. If the
program file contains no slashes, it is searched using $PATH.
(XXX There is no way to to include whitespace in the program
file or an argument, and under certain circumstances other
shell metacharacters are also a problem, e.g. the "foreground"
command of zdctl.py.)
NOTE: zdrun.py doesn't use this option; it uses its positional
arguments. Rather, zdctl.py uses this option to determine the
positional argument with which to invoke zdrun.py. (XXX This
could be better.)
</description>
</key>
<key name="python" datatype="existing-path"
required="no">
<description>
Path to the Python interpreter. Used by zdctl.py to start the
zdrun.py process. Defaults to sys.executable.
</description>
</key>
<key name="zdrun" datatype="existing-path"
required="no">
<description>
Path to the zdrun.py script. Used by zdctl.py to start the
zdrun.py process. Defaults to a file named "zdrun.py" in the
same directory as zdctl.py.
</description>
</key>
<key name="socket-name"
datatype="zdaemon.zdoptions.existing_parent_dirpath"
required="no"
default="zdsock">
<description>
Command-line option: -s or --socket-name.
The pathname of the Unix domain socket used for communication
between zdctl.py and zdrun.py. The default is relative to the
current directory in which zdctl.py and zdrun.py are started.
You want to specify an absolute pathname here.
</description>
</key>
<key name="daemon" datatype="boolean"
required="no"
default="on">
<description>
Command-line option: -d or --daemon.
If this option is true, zdrun.py runs in the background as a
true daemon. It forks a child process which becomes the
subprocess manager, while the parent exits (making the shell
that started it believe it is done). The child process also
does the following:
- if the directory option is set, change into that directory
- redirect stdin, stdout and stderr to /dev/null
- call setsid() so it becomes a session leader
- call umask() with specified value
</description>
</key>
<key name="directory"
datatype="zdaemon.zdoptions.existing_parent_directory"
required="no">
<description>
Command-line option: -z or --directory.
If the daemon option is true, this option can specify a
directory into which zdrun.py changes as part of the
"daemonizing". If the daemon option is false, this option is
ignored.
</description>
</key>
<key name="backoff-limit" datatype="integer"
required="no"
default="10">
<description>
Command-line option: -b or --backoff-limit.
When the subprocess crashes, zdrun.py inserts a one-second
delay before it restarts it. When the subprocess crashes
again right away, the delay is incremented by one second, and
so on. What happens when the delay has reached the value of
backoff-limit (in seconds), depends on the value of the
forever option. If forever is false, zdrun.py gives up at
this point, and exits. An always-crashing subprocess will
have been restarted exactly backoff-limit times in this case.
If forever is true, zdrun.py continues to attempt to restart
the process, keeping the delay at backoff-limit seconds.
If the subprocess stays up for more than backoff-limit
seconds, the delay is reset to 1 second.
</description>
</key>
<key name="forever" datatype="boolean"
required="no"
default="false">
<description>
Command-line option: -f or --forever.
If this option is true, zdrun.py will keep restarting a
crashing subprocess forever. If it is false, it will give up
after backoff-limit crashes in a row. See the description of
backoff-limit for details.
</description>
</key>
<key name="exit-codes" datatype="zdaemon.zdoptions.list_of_ints"
required="no"
default="0,2">
<description>
Command-line option: -x or --exit-codes.
If the subprocess exits with an exit status that is equal to
one of the integers in this list, zdrun.py will not restart
it. The default list requires some explanation. Exit status
0 is considered a willful successful exit; the ZEO and Zope
server processes use this exit status when they want to stop
without being restarted. (Including in response to a
SIGTERM.) Exit status 2 is typically issued for command line
syntax errors; in this case, restarting the program will not
help!
NOTE: this mechanism overrides the backoff-limit and forever
options; i.e. even if forever is true, a subprocess exit
status code in this list makes zdrun.py give up. To disable
this, change the value to an empty list.
</description>
</key>
<key name="user" datatype="string"
required="no">
<description>
Command-line option: -u or --user.
When zdrun.py is started by root, this option specifies the
user as who the the zdrun.py process (and hence the daemon
subprocess) will run. This can be a user name or a numeric
user id. Both the user and the group are set from the
corresponding password entry, using setuid() and setgid().
This is done before zdrun.py does anything else besides
parsing its command line arguments.
NOTE: when zdrun.py is not started by root, specifying this
option is an error. (XXX This may be a mistake.)
XXX The zdrun.py event log file may be opened *before*
setuid() is called. Is this good or bad?
</description>
</key>
<key name="umask" datatype="zdaemon.zdoptions.octal_type"
required="no"
default="022">
<description>
Command-line option: -m or --umask.
When daemon mode is used, this option specifies the octal umask
of the subprocess.
</description>
</key>
<key name="hang-around" datatype="boolean"
required="no"
default="false">
<description>
If this option is true, the zdrun.py process will remain even
when the daemon subprocess is stopped. In this case, zdctl.py
will restart zdrun.py as necessary. If this option is false,
zdrun.py will exit when the daemon subprocess is stopped
(unless zdrun.py intends to restart it).
</description>
</key>
<key name="default-to-interactive" datatype="boolean"
required="no"
default="true">
<description>
If this option is true, zdctl.py enters interactive mode
when it is invoked without a positional command argument. If
it is false, you must use the -i or --interactive command line
option to zdctl.py to enter interactive mode.
</description>
</key>
<key name="logfile" datatype="existing-dirpath"
required="no">
<description>
This option specifies a log file that is the default target of
the "logtail" zdctl.py command.
NOTE: This is NOT the log file to which zdrun.py writes its
logging messages! That log file is specified by the
<eventlog> section.
</description>
</key>
<key name="transcript" datatype="existing-dirpath"
required="no">
<description>
The name of a file in which a transcript of all output from
the command being run will be written to when daemonized.
If not specified, output from the command will be discarded.
This only takes effect when the "daemon" option is enabled.
</description>
</key>
<key name="prompt" datatype="string"
required="no">
<description>
The prompt shown by the controller program. The default must
be provided by the application.
</description>
</key>
</sectiontype>
<sectiontype name="environment" keytype="string">
<key name="+"
attribute="mapping"
required="no"
/>
</sectiontype>