1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 384 385 386 387 388 389 390 391 392 393 394 395 396 397 398 399 400 401 402 403 404 405 406 407 408 409 410 411 412 413 414 415 416 417 418 419 420 421 422 423 424 425 426 427 428 429 430 431 432 433 434 435 436 437 438 439 440 441 442 443 444 445 446 447 448 449 450 451 452 453 454 455 456 457 458 459 460 461 462 463 464 465 466 467 468 469 470 471 472 473 474 475 476 477 478 479 480 481 482 483 484 485 486 487 488 489 490 491 492 493 494 495 496 497 498 499 500 501 502 503 504 505 506 507 508 509 510 511 512 513 514 515 516 517 518 519 520 521 522 523 524 525 526 527 528 529 530 531 532 533 534 535 536 537 538 539 540 541 542 543 544 545 546 547 548 549 550 551 552 553 554 555 556 557 558 559 560 561 562 563 564 565 566 567 568 569 570 571 572 573 574 575 576 577 578 579 580 581 582 583 584 585 586 587 588 589 590 591 592 593 594 595 596 597 598 599 600 601 602 603 604 605 606 607 608 609 610 611 612 613 614 615 616 617 618 619 620 621 622 623 624 625 626 627 628 629 630 631 632 633 634 635 636 637 638 639 640 641 642 643 644 645 646 647 648 649 650 651 652 653 654 655 656 657 658 659 660 661 662 663 664 665 666 667 668 669 670 671 672 673 674 675 676 677 678 679 680 681 682 683 684 685 686 687 688 689 690 691 692 693 694 695 696 697 698 699 700 701 702 703 704 705 706 707 708 709 710 711 712 713 714 715 716 717 718 719 720 721 722 723 724 725 726 727 728 729 730 731 732 733 734 735 736 737 738 739 740 741 742 743 744 745 746 747 748 749 750 751 752 753 754 755 756 757 758 759 760 761 762 763 764 765 766 767 768 769 770 771 772 773 774 775 776 777 778 779 780 781 782 783 784 785 786 787 788 789 790 791 792 793 794 795 796 797 798 799 800 801 802 803 804 805 806 807 808 809 810 811 812 813 814 815 816 817 818 819 820 821 822 823 824 825 826 827 828 829 830 831 832 833 834 835 836 837 838 839 840 841 842 843 844 845 846 847 848 849 850 851 852 853 854 855 856 857 858 859 860 861 862 863 864 865 866 867 868 869 870 871 872 873 874 875 876 877 878 879 880 881 882 883 884 885 886 887 888 889 890 891 892 893 894 895 896 897 898 899 900 901 902 903 904 905 906 907 908 909 910 911 912 913 914 915 916 917 918 919 920 921 922 923 924 925 926 927 928 929 930 931 932 933 934 935 936 937 938 939 940 941 942 943 944 945 946 947 948 949 950 951 952 953 954 955 956 957 958 959 960 961 962 963 964 965 966 967 968 969 970 971 972 973 974 975 976 977 978 979 980 981 982 983 984 985 986 987 988 989 990 991 992 993 994 995 996 997 998 999 1000 1001 1002 1003 1004 1005 1006 1007 1008 1009 1010 1011 1012 1013 1014 1015 1016 1017 1018 1019 1020 1021 1022 1023 1024 1025 1026 1027 1028 1029 1030 1031 1032 1033 1034 1035 1036 1037 1038 1039 1040 1041 1042 1043 1044 1045 1046 1047 1048 1049 1050 1051 1052 1053 1054 1055 1056 1057 1058 1059 1060 1061 1062 1063 1064 1065 1066 1067 1068 1069 1070 1071 1072 1073 1074 1075 1076 1077 1078 1079 1080 1081 1082 1083 1084 1085 1086 1087 1088 1089 1090 1091 1092 1093 1094 1095 1096 1097 1098 1099 1100 1101 1102 1103 1104 1105 1106 1107 1108 1109 1110 1111 1112 1113 1114 1115 1116 1117 1118 1119 1120 1121 1122 1123 1124 1125 1126 1127 1128 1129 1130 1131 1132 1133 1134 1135 1136 1137 1138 1139 1140 1141 1142 1143 1144 1145 1146 1147 1148 1149 1150 1151 1152 1153 1154 1155 1156 1157 1158 1159 1160 1161 1162 1163 1164 1165 1166 1167 1168 1169 1170 1171 1172 1173 1174 1175 1176 1177 1178 1179 1180 1181 1182 1183 1184 1185 1186 1187 1188 1189 1190 1191 1192 1193 1194 1195 1196 1197 1198 1199 1200 1201 1202 1203 1204 1205 1206 1207 1208 1209 1210 1211 1212 1213 1214 1215 1216 1217 1218 1219 1220 1221 1222 1223 1224 1225 1226 1227 1228 1229 1230 1231 1232 1233 1234 1235 1236 1237 1238 1239 1240 1241 1242 1243 1244 1245 1246 1247 1248 1249 1250 1251 1252 1253 1254 1255 1256 1257 1258 1259 1260 1261 1262 1263 1264 1265 1266 1267 1268 1269 1270 1271 1272 1273 1274 1275 1276 1277 1278 1279 1280 1281 1282 1283 1284 1285 1286 1287 1288 1289 1290 1291 1292 1293 1294 1295 1296 1297 1298 1299 1300 1301 1302 1303 1304 1305 1306 1307 1308 1309 1310 1311 1312 1313 1314 1315 1316 1317 1318 1319 1320 1321 1322 1323 1324 1325 1326 1327 1328 1329 1330 1331 1332 1333 1334 1335 1336 1337 1338 1339 1340 1341 1342 1343 1344 1345 1346 1347 1348 1349 1350 1351 1352 1353 1354 1355 1356 1357 1358 1359 1360 1361 1362 1363 1364 1365 1366 1367 1368 1369 1370 1371 1372 1373 1374 1375 1376 1377 1378 1379 1380 1381 1382 1383 1384 1385 1386 1387 1388 1389 1390 1391 1392 1393 1394 1395 1396 1397 1398 1399 1400 1401 1402 1403 1404 1405 1406 1407 1408 1409 1410 1411 1412 1413 1414 1415 1416 1417 1418 1419 1420 1421 1422 1423 1424 1425 1426 1427 1428 1429 1430 1431 1432 1433 1434 1435 1436 1437 1438 1439 1440 1441 1442 1443 1444 1445 1446 1447 1448 1449 1450 1451 1452 1453 1454 1455 1456 1457 1458 1459 1460 1461 1462 1463 1464 1465 1466 1467 1468 1469 1470 1471 1472 1473 1474 1475 1476 1477 1478 1479 1480 1481 1482 1483 1484 1485 1486 1487 1488 1489 1490 1491 1492 1493 1494 1495 1496 1497 1498 1499 1500 1501 1502 1503 1504 1505 1506 1507 1508 1509 1510 1511 1512 1513 1514 1515 1516 1517 1518 1519 1520 1521 1522 1523 1524 1525 1526 1527 1528 1529 1530 1531 1532 1533 1534 1535 1536 1537 1538 1539 1540 1541 1542 1543 1544 1545 1546 1547 1548 1549 1550 1551 1552 1553 1554 1555 1556 1557 1558 1559 1560 1561 1562 1563 1564 1565 1566 1567 1568 1569 1570 1571 1572 1573 1574 1575 1576 1577 1578 1579 1580 1581 1582 1583 1584 1585 1586 1587 1588 1589 1590 1591 1592 1593 1594 1595 1596 1597 1598 1599 1600 1601 1602 1603 1604 1605 1606 1607 1608 1609 1610 1611 1612 1613 1614 1615 1616 1617 1618 1619 1620 1621 1622 1623 1624 1625 1626 1627 1628 1629 1630 1631 1632 1633 1634 1635 1636 1637 1638 1639 1640 1641 1642 1643 1644 1645 1646 1647 1648 1649 1650 1651 1652 1653 1654 1655 1656 1657 1658 1659 1660 1661 1662 1663 1664 1665 1666 1667 1668 1669 1670 1671 1672 1673 1674 1675 1676 1677 1678 1679 1680 1681 1682 1683 1684 1685 1686 1687 1688 1689 1690 1691 1692 1693 1694 1695 1696 1697 1698 1699 1700 1701 1702 1703 1704 1705 1706 1707 1708 1709 1710 1711 1712 1713 1714 1715 1716 1717 1718 1719 1720 1721 1722 1723 1724 1725 1726 1727 1728 1729 1730 1731 1732 1733 1734 1735 1736 1737 1738 1739 1740 1741 1742 1743 1744 1745 1746 1747 1748 1749 1750 1751 1752 1753 1754 1755 1756 1757 1758 1759 1760 1761 1762 1763 1764 1765 1766 1767 1768 1769 1770 1771 1772 1773 1774 1775 1776 1777 1778 1779 1780 1781 1782 1783 1784 1785 1786 1787 1788 1789 1790 1791 1792 1793 1794 1795 1796 1797 1798 1799 1800 1801 1802 1803 1804 1805 1806 1807 1808 1809 1810 1811 1812 1813 1814 1815 1816 1817 1818 1819 1820 1821 1822 1823 1824 1825 1826 1827 1828 1829 1830 1831 1832 1833 1834 1835 1836 1837 1838 1839 1840 1841 1842 1843 1844 1845 1846 1847 1848 1849 1850 1851 1852 1853 1854 1855 1856 1857 1858 1859 1860 1861 1862 1863 1864 1865 1866 1867 1868 1869 1870 1871 1872 1873 1874 1875 1876 1877 1878 1879 1880 1881 1882 1883 1884 1885 1886 1887 1888 1889 1890 1891 1892 1893 1894 1895 1896 1897 1898 1899 1900 1901 1902 1903 1904 1905 1906 1907 1908 1909 1910 1911 1912 1913 1914 1915 1916 1917 1918 1919 1920 1921 1922 1923 1924 1925 1926 1927 1928 1929 1930 1931 1932 1933 1934 1935 1936 1937 1938 1939 1940 1941 1942 1943 1944 1945 1946 1947 1948 1949 1950 1951 1952 1953 1954 1955 1956 1957 1958 1959 1960 1961 1962 1963 1964 1965 1966 1967 1968 1969 1970 1971 1972 1973 1974 1975 1976 1977 1978 1979 1980 1981 1982 1983 1984 1985 1986 1987 1988 1989 1990 1991 1992 1993 1994 1995 1996 1997 1998 1999 2000 2001 | <!DOCTYPE HTML PUBLIC "-//W3C//DTD HTML 4.01 Transitional//EN">
<html>
<head>
<title>Argyll Usage Scenarios</title>
<meta http-equiv="content-type"
content="text/html; charset=ISO-8859-1">
</head>
<body>
<h2><u>Typical usage Scenarios and Examples</u></h2>
Choose a task from the list below. For more details on alternative
options, follow the links to the individual tools being used.<br>
<br>
Note that by default it is assumed that ICC profile have the file
extension <span style="font-weight: bold;">.icm</span>, but that on
Apple OS X and Unix/Linux platforms, the <span
style="font-weight: bold;">.icc</span> extension is expected and
should be used.<br>
<h4><a href="#PM1">Profiling Displays</a></h4>
<h4> <a href="#PM1a">Checking you can access your
display<br>
</a></h4>
<h4> <a href="#PM1b">Adjusting and Calibrating
a
displays</a></h4>
<h4> <a href="#PM1c">Adjusting, calibrating and
profiling in one step<br>
</a><span style="font-weight: bold;"></span><span
style="font-weight: bold;"></span><span
style="text-decoration: underline;"></span></h4>
<h4> <a href="#PM2">Creating display test values</a></h4>
<h4> <a href="#PM3">Taking readings from a display</a></h4>
<h4> <a href="#PM4">Creating a
display profile</a></h4>
<h4> <span style="text-decoration: underline;"></span><a
href="#PM5">Installing a
display profile</a></h4>
<h4> <span style="text-decoration: underline;"></span><a
href="#PM6">Expert tips when measuring displays</a></h4>
<h4><br>
<a href="#PS1">Profiling Scanners and other input devices such as
cameras<br>
</a></h4>
<h4> <a href="#PS2">Types of test charts</a></h4>
<h4> <a href="#PS3">Taking readings from a scanner</a></h4>
<h4> <a href="#PS4">Creating a scanner profile</a></h4>
<h4><br>
<a href="#PP1">Profiling Printers</a></h4>
<h4> <a href="#PP2">Creating a print profile test
chart</a></h4>
<h4> <a href="Scenarios.html#PP2b">Printing a print
profile test chart</a></h4>
<h4> <a href="#PP3">Reading a print test chart
using an instrument</a></h4>
<h4> <a href="#PP4">Reading a print test chart
using a scanner</a></h4>
<h4> </h4>
<h4> <a href="#PP5">Creating a printer profile<br>
</a></h4>
<h4> <a href="#PP6">Choosing a black generation curve</a></h4>
<br>
<h4><a href="Scenarios.html#PC1">Calibrating Printers</a></h4>
<h4> <a href="Scenarios.html#PC2">Calibrated print
workflows</a></h4>
<h4> <a href="Scenarios.html#PC3">Creating a print
calibration test chart</a></h4>
<h4> </h4>
<h4> <a href="Scenarios.html#PC4">Creating a printer
calibration<br>
</a></h4>
<h4> <a href="Scenarios.html#PC5">Using a printer
calibration</a></h4>
<h4> <a href="#PC6">How profile ink limits are
handled when calibration is being used<br>
</a></h4>
<h4><br>
<a href="#LP1">Linking Profiles</a></h4>
<h4><br>
<a href="#TR1">Transforming colorspaces of raster files</a></h4>
<br>
<hr style="width: 100%; height: 2px;"><br>
<h3><a name="PM1"></a>Profiling Displays</h3>
Argyll supports adjusting, calibrating and profiling of displays using
one of a number of
instruments - see <a href="instruments.html">instruments</a> for a
current list. Adjustment and calibration are prior
steps to profiling, in which the display is adjusted using it's
screen controls, and then per channel lookup tables are created
to make it meet a well behaved response
of the desired type. The process following that of creating a
display profile is then similar to that of all other
output
devices :- first a set of device colorspace test values needs to be
created to exercise the display, then these values need to be
displayed, while taking measurements of the resulting colors using the
instrument. Finally, the device value/measured color values need to be
converted into an ICC profile.<br>
<br>
<h3><a name="PM1a"></a>Checking you can access your display<br>
</h3>
You might first want to check that you are accessing and can calibrate
your display. You can do this using the <a href="dispwin.html">dispwin</a><span
style="font-weight: bold;"></span> tool<span style="font-weight: bold;">.</span>
If you just run <span style="font-weight: bold;">dispwin</span>
it will create a test window and run through a series of test colors
before checking that the VideoLUT can be accessed by the display. If
you invoke the usage for <span style="font-weight: bold;">dispwin</span>
(by giving it an unrecognized option, e.g. <span
style="font-weight: bold;">-?</span>) then it will show a list of
available displays next to the <span style="font-weight: bold;"><span
style="font-weight: bold;">-d</span></span>
flag. Make sure that you are accessing the display you intend to
calibrate and profile, and that the VideoLUT is effective (the <span
style="font-weight: bold;">-r</span> flag can be used to just run the
VideoLUT test). You can also try clearing the VideoLUTs using the <span
style="font-weight: bold;">-c</span> flag, and loading a deliberately
strange looking calibration <span style="font-weight: bold;">strange.cal</span>
that is provided in the Argyll <span style="font-weight: bold;">ref</span>
directory.<br>
<br>
<h3><a name="PM1b"></a>Adjusting and Calibrating Displays</h3>
Please read <a href="calvschar.html">What's the difference between
Calibration and Characterization ?</a> if you are unclear as to the
difference .<br>
<br>
The first step is to decide what the target should be for adjustment
and calibration.
This boils down to three things: The desired brightness, the desired
white point, and the desired response curve. The native brightness and
white points of a display may be different to the desired
characteristics for some purposes. For instance, for graphic arts use,
it might be desirable to run with a warmer white point of about 5000
degrees Kelvin, rather than the default display white point of 6500 to
9000 Kelvin. Some LCD displays are too bright to compare to printed
material under available lighting, so it might be desirable to reduce
the maximum brightness.<br>
<br>
You can run <a href="dispcal.html#r">dispcal -r</a> to check on how
your display is currently set up. (you may have to run this as <span
style="text-decoration: underline; color: rgb(204, 51, 204);">dispcal
-yl -r</span> for an LCD display, or <span
style="text-decoration: underline; color: rgb(204, 51, 204);">dispcal
-yc -r</span> for a CRT display with most of the colorimeter
instruments. If so, this will apply to all of the following examples.)<br>
<br>
Once this is done, <a href="dispcal.html">dispcal</a> can be run to
guide you through the display adjustments, and then calibrate it. By
default, the brightness and white point will be kept
the same as the devices natural brightness and white point. The default
response curve is a gamma of 2.4, except for Apple OS X systems prior
to 10.6 where a gamma of 1.8 is the default. 2.4 is close to that
of many
monitors, and close to that of the sRGB colorspace. <br>
<br>
A typical calibration that leaves the brightness and white point alone,
might be:<br>
<br>
<a href="dispcal.html">dispcal</a> -v TargetA<br>
<br>
which will result in a "TargetA.cal" calibration file, that can then be
used during the profiling stage.<br>
<br>
If the absolutely native response of the display is desired during
profiling, then calibration should be skipped, and the linear.cal file
from the "ref" directory used instead as the argument to the -k flag of
<span style="font-weight: bold;">dispread</span>.<br>
<br>
<b>Dispcal</b> will display a test window in the middle of the screen,
and issue a series of instructions about placing the instrument on the
display. You may need to make sure that the display cursor is not in
the test window, and it may also be necessary to disable any
screensaver and powersavers before starting the
process, although both <span style="font-weight: bold;">dispcal</span>
and <span style="font-weight: bold;">dispread</span> will attempt to
do this for you. It's also highly desirable on CRT's, to clear your
screen
of
any white
or bright background images or windows (running your shell window with
white text on a black background helps a lot here.), or at least keep
any bright areas away from the test window, and be careful not to
change anything on the display while the readings
are taken. Lots of bright images or windows can affect the ability to
measure
the black point accurately, and changing images on the display can
cause inconsistency in the readings, and leading to poor results.<span
style="font-weight: bold;"></span> LCD displays seem to be
less influenced by what else is on the screen.<br>
<br>
If <span style="font-weight: bold;">dispcal</span> is run
without arguments, it will provide a usage screen. The <span
style="font-weight: bold;">-c</span> parameter allows selecting a
communication port for an instrument, or selecting the instrument you
want to use, and the <a href="dispcal.html#d"><span
style="font-weight: bold;">-d</span></a>
option allows selecting a target
display on a multi-display system. On some multi-monitor systems, it
may not be possible to independently calibrate and profile each display
if they appear as one single screen to the operating system, or if it
is not possible to set separate video lookup tables for each
display. You can change the position and size of the test
window using the <a href="dispcal.html#P"><span
style="font-weight: bold;">-P</span></a> parameter.
You can determine how best to arrange the test window, as well as
whether each display has separate video lookup capability, by
experimenting with the <a href="dispwin.html">dispwin</a> tool. <br>
<br>
For a more detailed discussion on interactively adjusting the display
controls using <span style="font-weight: bold;">dispcal</span>, see <a
href="dispcal.html#Adjustment">dispcal-adjustment</a>. Once you have
adjusted and calibrated your display, you can move on to the next step.<br>
<br>
When you have calibrated and profiled your display, you can keep it
calibrated using the <a href="dispcal.html#u">dispcal -u</a> option.<br>
<br>
<h4><a name="PM1c"></a>Adjusting, calibrating and profiling in one step.</h4>
If a simple matrix/shaper display profile is all
that is desired, <span style="font-weight: bold;">dispcal</span> can
be used to do this, permitting display adjustment, calibration and
profiling all in one operation. This is done by using the <span
style="font-weight: bold;"><span style="font-weight: bold;">dispcal </span>-o</span>
flag:<br>
<br>
<a href="dispcal.html">dispcal</a> <a href="dispcal.html#v">-v</a> <a
href="dispcal.html#o">-o</a> <a href="dispcal.html#p1">TargetA</a><br>
<br>
This will create both a TargetA.cal file, but also a TargetA.icm file.
See <a href="dispcal.html#o">-o</a> and <a href="dispcal.html#O">-O</a>
for other variations.<br>
<br>
For more flexibility in creating a display profile, the separate steps
of creating characterization test values using <span
style="font-weight: bold;">targen</span>, reading them from the
display using <span style="font-weight: bold;">dispread</span>, and
then creating a profile using <span style="font-weight: bold;">colprof</span>
are used. The following steps illustrate this:<br>
<h4><a name="PM2"></a>Profiling in several steps: Creating display test
values</h4>
If the <span style="font-weight: bold;">dispcal</span> has not been
used to create a display profile at the same time as adjustment and
calibration, then the first step in profiling any output device, is to
create a set
of device colorspace test values. The important parameters needed are:
<br>
<ul>
<li>What colorspace does the device use ?</li>
<li>How many test patches do I want to use ?</li>
<li>What information do I already have about how the device behaves ?</li>
</ul>
For a display device, the colorspace will be RGB. The number of
test patches will depend somewhat on what quality profile you want to
make, what type of profile you want to make, and how long you are
prepared to wait when testing the display.<br>
At a minimum, a few hundred values are needed. A matrix/shaper type of
profile can get by with fewer test values, while a LUT based profile
will give better results if more test values are used. A typical number
might be 200-600 or so values, while 1000-2000 is not an unreasonable
number for a high quality characterization of a display.<br>
<br>
To assist the choice of test patch values, it can help to have a rough
idea of how the device behaves. This could be in the form of an ICC
profile of a similar device, or a lower quality, or previous profile
for that particular device. If one were going to make a very high
quality LUT based profile, then it might be worthwhile to make up a
smaller, preliminary shaper/matrix profile using a few hundred test
points, before embarking on testing the device with several thousand.<br>
<br>
Lets say that we ultimately want to make a profile for the device
"DisplayA", the simplest approach is to make a set of test values that
is
independent of the characteristics of the particular device:<br>
<br>
<a href="targen.html">targen</a> <a href="targen.html#v">-v</a> <a
href="targen.html#d">-d3</a> <a href="targen.html#f">-f500</a> <a
href="targen.html#p1">DisplayA</a><br>
<br>
If there is a preliminary or previous profile called "OldDisplay"
available, and we want to try creating a "pre-conditioned" set of test
values that will more efficiently sample the device response, then the
following would achieve this:<br>
<u><br>
</u><a href="targen.html"> targen</a> <a href="targen.html#v">-v</a>
<a href="targen.html#d">-d3</a> <a href="targen.html#f">-f500</a>
<a href="targen.html#c">-cOldDisplay.icm</a>
<a href="targen.html#p1">DisplayA</a><br>
<br>
The output of <b>targen</b> will be the file DisplayA.ti1, containing
the device space test values, as well as expected CIE values used for
chart recognition purposes.<br>
<br>
<h4><a name="PM3"></a>Profiling in several steps: Taking readings from
a display</h4>
First it is necessary to connect your measurement instrument to your
computer, and check which communication port it is connected to. In the
following example, it is assumed that the instrument is connected to
the default port 1, which is either the first USB instrument found, or
serial port found. Invoking dispread so as to display the usage
information
(by
using a flag -? or --) will list the identified serial and USB ports,
and their
labels. If we created a calibration for the display using <a
href="dispcal.html">dispcal</a>, then we will want to use this when we
take the display readings (e.g. TargetA.cal from the calibration
example)..<br>
<br>
<a href="dispread.html">dispread</a> <a href="dispread.html#v">-v</a> <a
href="dispread.html#k">-k
TargetA.cal</a> <a href="dispread.html#p1">DisplayA</a><br>
<br>
<b>dispread</b> will display a test window in the middle of the screen,
and issue a series of instructions about placing the instrument on the
display. You may need to make sure that the display cursor is not in
the test window, and it may also be necessary to disable any
screensaver before starting the
process. Exactly the same facilities are provided to select alternate
displays using the <span style="font-weight: bold;">-d</span>
parameter, and an alternate location and size for the test window using
the <span style="font-weight: bold;">-P</span> parameter as with <span
style="font-weight: bold;">dispcal</span>.<br>
<h4><a name="PM4"></a>Profiling in several steps: Creating a display
profile</h4>
There are two basic choices of profile type for a display, a
shaper/matrix profile, or a LUT based profile. They have different
tradeoffs. A shaper/matrix profile will work well on a well behaved
display, that is one that behaves in an additive color manner, will
give
very smooth looking results, and needs fewer test points to create. A
LUT based profile on the other hand, will model any display behaviour
more accurately, and can accommodate gamut mapping and different intent
tables. Often it can show some unevenness and contouring in the results
though.<br>
<br>
To create a matrix/shaper profile, the following suffices:<br>
<br>
<a href="colprof.html">colprof</a> <a href="colprof.html#v">-v</a> <a
href="colprof.html#E">-D"Display A"</a> <a href="colprof.html#q">-qm</a>
<a href="colprof.html#a">-as</a> <a href="colprof.html#p1">DisplayA</a><br>
<br>
For a LUT based profile, where gamut mapping is desired, then a source
profile will need to be provided to define the source gamut. For
instance, if the display profile was likely to be linked to a CMYK
printing source profile, say "swop.icm", then the following would
suffice:<br>
<br>
<a href="colprof.html">colprof</a> <a href="colprof.html#v">-v</a> <a
href="colprof.html#E">-D"Display A"</a>
<a href="colprof.html#q">-qm</a> <a href="colprof.html#S">-S</a><a
href="colprof.html#S">
swop.icm</a> <a href="colprof.html#c">-cpp</a> <a
href="colprof.html#d">-dmt</a>
<a href="colprof.html#p1">DisplayA</a><br>
<br>
Make sure you check the delta E report at the end of the profile
creation, to see if the profile is behaving reasonably.<br>
If a calibration file was used with <a href="dispread.html">dispread</a>,
then
it
will
be
converted to a vcgt tag in the profile, so that the
operating system or other system color tools load the lookup curves
into the display hardware, when the profile is used.<br>
<h4><a name="PM5"></a>Installing a display profile</h4>
<a href="dispwin.html">dispwin</a> provides a convenient way of
installing a profile as the default system profile for the chosen
display:<br>
<br>
<a href="dispwin.html">dispwin</a> <a href="dispwin.html#I">-I</a> <a
href="dispwin.html#p1">DisplayA.icm</a><br>
<br>
This also sets the display to the calibration contained in the profile.
If you want to try out a calibration before installing the profile,
using dispwin without the <span style="font-weight: bold;">-I</span>
option will load a calibration (ICC profile or .cal file) into the
current display.<br>
<br>
Some systems will automatically set the display to the calibration
contained in the installed profile (ie. OS X), while on other systems
(ie. MSWindows and Linux/X11) it is necessary to use some tool to do
this. On MSWindows XP you could install the optional <span
style="font-weight: bold;">Microsoft Color Control Panel Applet for Windows XP</span>
available for
download from
Microsoft to do this, but <span style="font-weight: bold;">NOTE</span>
however that it seems to
have a <span style="font-weight: bold;">bug</span>, in that it
sometimes associates the profiles with the <span
style="font-weight: bold;">wrong monitor</span> entry. Other display
calibration tools will often install a similar tool, so beware
of there being multiple, competing programs. [ Commonly these will be
in your Start->Programs->Startup folder. ]<br>
On Microsoft Vista, you need to use dispwin -L or some other tool to
load the installed profiles calibration at startup.<br>
<br>
To use dispwin to load the installed profiles calibration to the
display, use<br>
<br>
<a href="dispwin.html">dispwin</a> <a href="dispwin.html#L">-L</a><br>
<br>
As per usual, you can select the appropriate display using the <a
href="dispwin.html#d">-d</a> flag.<br>
<br>
This can be automated on MSWindows and X11/Linux by adding this command
to an appropriate startup script.<br>
More system specific details, including how to create such startup
scripts are <a href="dispprofloc.html">here</a>. <br>
<br>
If you are using Microsoft <span style="font-weight: bold;">Vista</span>,
there
is
a
known
<span style="font-weight: bold;">bug</span> in Vista
that resets the calibration every time a
fade-in effect is executed, which happens if you lock and unlock the
computer, resume from sleep or hibernate, or User Access Control is
activated. Using <a href="dispwin.html">dispwin</a> <a
href="dispwin.html#L">-L</a> may not restore the calibration, because
Vista filters out setting (what it thinks) is a calibration that is
already loaded. Use <a href="dispwin.html">dispwin</a> <a
href="dispwin.html#c">-c</a> <a href="dispwin.html#L">-L</a><span
style="font-family: monospace;"></span> as a workaround, as this will
first clear the calibration, then re-load the current calibration.<br>
<br>
On X11/Linux systems, you could try adding <a href="dispwin.html">dispwin</a>
<a href="dispwin.html#L">-L</a> to your <span
style="font-weight: bold;">~/.config/autostart</span> file, so that
your window manager automatically sets calibration when it starts. If
you are running XRandR 1.2, you might
consider running the experimental <a href="dispwin.html#D">dispwin -E</a>
in the background, as in its "daemon" mode it will
update the profile and calibration in response to any changes in the
the connected display.<br>
<br>
<h4><a name="PM6"></a>Expert tips when measuring displays:<br>
</h4>
Sometimes it can be difficult to get good quality, consistent and
visually relevant readings from displays, due to various practical
considerations with regard to instruments and the displays themselves.
Argyll's tools have some extra options that may assist in overcoming
these problems.<br>
<br>
If you are using an Eye-One Pro or ColorMunki spectrometer, then you
may wish to use the <a href="dispcal.html#H">high resolution spectral
mode</a> (<span style="font-weight: bold;">-H</span>). This may be
better at capturing the often narrow wavelength peaks that are typical
of display primary colors.<br>
<br>
Another option that can be used with the Eye-One Pro or ColorMunki
spectrometer is the <a href="dispcal.html#V">adaptive measurement mode</a>
(<span style="font-weight: bold;">-V</span>). By default a fixed
measurement integration time is used, as this will give the most
consistent results, but for displays with high contrast ratio's and
deep blacks, the integration time may be too short to give adequate
precision. The adaptive measurement mode increases integration time
when measuring dark colors (which will increase the overall calibration
or profiling time), and is capable of achieving higher precision for
these dark measurements.<br>
<br>
All instruments depend on silicon sensors, and such sensors generate a
temperature dependant level of noise ("dark noise") that is factored
out of the measurements by a dark or black instrument calibration. The
spectrometers in particular need this calibration before commencing
each set of measurements. Often an instrument will warm up as it sits
on a display, and this warming up can cause the dark noise to increase,
leading to inaccuracies in dark patch measurements. The longer the
measurement takes, the worse this problem is likely to be. One way of
addressing this is to "acclimatise" the instrument before commencing
measurements by placing it on the screen in a powered up state, and
leaving it for some time. (Some people leave it for up to an hour to
acclimatise.). Another approach is to try and <a href="dispcal.html#I">compensate
for
dark
calibration
changes</a> (<span style="font-weight: bold;">-Ib</span>)
by
doing on the fly calibrations during the measurements, based on the
assumption that the black level of the display itself won't change
significantly. <br>
<br>
Some displays take a long time to settle down and stabilise. The is
often the case with LCD (Liquid Crystal) displays that use fluorescent
back lights, and these sorts of displays can change in brightness
significantly with changes in temperature. One way of addressing this
is to make sure that the display is given adequate time to warm up
before measurements. Another approach is to try and <a
href="dispcal.html#I">compensate for display white level</a>
(<span style="font-weight: bold;">-Iw</span>) changes by doing on the
fly calibrations during the measurements. Instrument black level drift
and display white level drift can be combined (<span
style="font-weight: bold;">-Ibw</span>).<br>
<br>
Colorimeter instruments make use of physical color filters that
approximate the standard observer spectral sensitivity curves. Because
these filters are not perfectly accurate, the manufacturer calibrates
the instrument for typical displays, which is why you have to make a
selection between CRT (Cathode Ray Tube) and LCD (Liquid Crystal
Display) modes. If you are measuring a display that has primary
colorants that differ significantly from those typical displays,
(ie. you have a Wide Gamut Display), then you may get disappointing
results with a Colorimeter. One way of addressing this problem is to
use a <a href="File_Formats.html#.ccmx">Colorimeter Correction Matrix</a>.
These
are
specific
to
a particular Colorimeter and Display make and
model combination, although a matrix for a different but similar type
of display may give better results than none at all. A list of
contributed <span style="font-weight: bold;">ccmx</span> files is <a
href="ccmxs.html">here</a>.<br>
<span style="font-weight: bold;"></span><br>
<hr size="2" width="100%">
<h3><a name="PS1"></a>Profiling Scanners and other input devices such
as cameras<br>
</h3>
Because a scanner or camera is an input device, it is necessary to go
about
profiling it in quite a different way to an output device. To profile
it, a test chart is needed to exercise the input device response, to
which
the CIE values for each test patch is known. Generally standard
reflection or transparency test charts are used for this purpose.<br>
<h4><a name="PS2"></a>Types of test charts</h4>
The most common and popular test chart for scanner profiling is the
IT8.7/2 chart. This is a standard format chart generally reproduced on
photographic film, containing about 264 test patches.<br>
An accessible and
affordable source of such targets is Wolf Faust a <a
href="http://www.targets.coloraid.de/">www.coloraid.de</a>.<br>
Another source is LaserSoft <a
href="http://www.silverfast.com/show/it8/en.html">www.silverfast.com.</a><br>
The Kodak Q-60
Color Input Target is also a typical example:<br>
<br>
<img src="Q60.jpg" alt="Kodak Q60 chart image" height="141" width="200">
<br>
<br>
A very simple chart that is widely available is the Macbeth
ColorChecker chart, although it contains only 24 patches and therefore
is probably not ideal for creating profiles:<br>
<img alt="ColorChecker 24 patch" src="colorchecker.jpg"
style="width: 112px; height: 78px;"><br>
<br>
Other popular charts are the X-Rite/GretagMacbeth ColorChecker DC and
<a href="http://www.xrite.com/product_overview.aspx?ID=938">ColorChecker
SG</a> charts:<br>
<br>
<img src="DC.jpg" alt="GretagMacbeth ColorChecker DC chart" height="122"
width="200"> <img alt="ColorChecker SG" src="SG.jpg"
style="width: 174px; height: 122px;"><br>
<br>
The GretagMacbeth Eye-One Pro Scan Target 1.4 can also be used:<br>
<br>
<img alt="Eye-One Scan Target 1.4" src="i1scan14.jpg"
style="border: 2px solid ; width: 200px; height: 140px;"><br>
<br>
Also supported is the <a href="http://www.hutchcolor.com/hct.htm">HutchColor
HCT</a> :<br>
<br>
<img alt="HutchColor HCT" src="HCT.jpg"
style="width: 182px; height: 140px;"><br>
<br>
<br>
and <a
href="http://www.christophe-metairie-photographie.com/eng%20digital%20target.html">Christophe
Métairie's
Digital
TargeT
003</a> and <a
href="http://www.christophe-metairie-photographie.com/eng%20digital%20target.html">Christophe
Métairie's
Digital
Target
-
3</a> :<br>
<br>
<img alt="CMP_DT_003" src="CMP_DT_003.jpg"
style="width: 186px; height: 141px;"> <img
style="width: 203px; height: 140px;" alt="CMP_Digital_Target-3"
src="CMP_Digital_Target-3.jpg"><br>
<br>
and the <a href="http://www.silverfast.com/show/dc-targets/en.html">LaserSoft
Imaging
DCPro
Target</a>:<br>
<br>
<img style="width: 153px; height: 122px;" alt="LaserSoft DCPro Target"
src="LSDC.jpg"><br>
<br>
<h4><a name="PS3"></a>Taking readings from a scanner or camera<br>
</h4>
The test chart you are using needs to be placed on the scanner, and the
scanner needs to be configured to a suitable state, and restored to
that
same state when used subsequently with the resulting profile. For a
camera, the chart needs to be lit in a controlled and even manner using
the light source that will be used for subsequent photographs, and
should be shot so as to minimise any geometric distortion, although the
<a href="scanin.html#p">scanin -p</a> flag may be used to compensate
for some degree of distortion. As with any color profiling task, it is
important to setup a known and repeatable image processing flow, to
ensure that the resulting profile will be usable.<br>
<br>
The chart
should
be captured and saved to a TIFF format file. I will assume the
resulting
file is called scanner.tif. The raster file need only be roughly
cropped so as to contain the test chart (including the charts edges).<br>
<br>
The second step is to extract the RGB values from the scanner.tif file,
and match then to the reference CIE values.
To locate the patch values in the scan, the <b>scanin</b> tool
needs to
be given a template <a href="File_Formats.html#.cht">.cht</a> file
that describes the features of the chart, and
how
the test patches are labeled. Also needed is a file containing the CIE
values for each of the patches in the chart, which is typically
supplied with the chart, available from the manufacturers web site, or
has been measured using a spectrometer.<br>
<br>
<div style="margin-left: 40px;">For an IT8.7/2 chart, this is the <span
style="font-weight: bold;">ref/</span><b>it8.cht</b>
file supplied with Argyll, and the manufacturer will will supply
an
individual or batch average file along with the chart containing
this
information, or downloadable from their web site.<br>
NOTE that the reference file for the IT8.7/2 chart supplied with <span
style="font-weight: bold;">Monaco EZcolor</span> can be obtained
by unzipping the .mrf file. (You may have to make a copy of the file
with a .zip extension to do this.)<br>
<br>
For the ColorChecker 24 patch chart, the
<span style="font-weight: bold;">ref/ColorChecker.cht</span> file
should be used, and there is also a <span style="font-weight: bold;">ref/ColorChecker.cie</span>
file provided that is based on the manufacturers reference values for
the chart. You can also create your own reference file using an
instrument and chartread, making use of the chart reference file <span
style="font-weight: bold;">ref/ColorChecker.ti2</span>:<br>
<a href="chartread.html">chartread</a> -n -a
ColorChecker.ti2<br>
Note that due to the small number of patches, a profile created from
such a chart is not likely to be very detailed.<br>
<br>
For the ColorChecker DC chart, the
<span style="font-weight: bold;">ref/ColorCheckerDC.cht</span> file
should be used, and there will be a ColorCheckerDC reference
file supplied by X-Rite/GretagMacbeth with the chart.<br>
<br>
The ColorChecker SG is relatively expensive, but is preferred by many
people because (like the ColorChecker and ColorCheckerDC) its colors
are composed of multiple different pigments,
giving it reflective spectra that are more representative of the real
world, unlike many other charts that are created out of combination of
3 or 4 colorants.<br>
A limited CIE reference file is available from X-Rite <a
href="http://www.xrite.com/documents/apps/public/digital_colorchecker_sg_l_a_b.txt">here</a>,
but
it
is
not
in the usual CGATS format. To convert it to a CIE
reference file useful for <span style="font-weight: bold;">scanin</span>,
you
will
need
to
edit the X-Rite file using a <span style="text-decoration: underline;">plain
text</span> editor, first
deleting everything before the line starting with "A1" and everything
after "N10", then prepending <a href="SG_header.txt">this header</a>,
and appending <a href="SG_footer.txt">this footer</a>, making sure
there are no blank lines inserted in the process.<br>
If you do happen to have access to a more comprehensive instrument
measurement of the ColorChecker SG, or you have measured it yourself
using a color instrument,<br>
then you <span style="text-decoration: underline;">may</span> need to
convert the reference information from spectral <span
style="font-weight: bold;">ColorCheckerSG.txt</span> file to CIE value
<span style="font-weight: bold;">ColorCheckerSG.cie</span>
reference file,
follow the following steps:<br>
<a href="txt2ti3.html">txt2ti3</a>
ColorCheckerSG.txt ColorCheckerSG<br>
<a href="spec2cie.html">spec2cie</a>
ColorCheckerSG.ti3 ColorCheckerSG.cie<br>
<br>
For the Eye-One Pro Scan Target 1.4 chart, the <span
style="font-weight: bold;"><span style="font-weight: bold;">ref/</span>i1_RGB_Scan_1.4.cht</span>
file should be used, and as there is no reference file accompanying
this chart, the chart needs to be read with an instrument (usually the
Eye-One Pro). This can be done using chartread, making use of the
chart reference file <span style="font-weight: bold;">ref/i1_RGB_Scan_1.4.ti2</span>:<br>
<a href="chartread.html">chartread</a> -n -a
i1_RGB_Scan_1.4<br>
and then rename the resulting <span style="font-weight: bold;">i1_RGB_Scan_1.4.ti3</span>
file to <span style="font-weight: bold;">i1_RGB_Scan_1.4.cie</span><br>
<span style="font-weight: bold;"></span><br>
For the HutchColor HCT chart, the <span style="font-weight: bold;"><span
style="font-weight: bold;">ref/</span>Hutchcolor.cht</span> file
should be used, and the reference <span style="font-weight: bold;">.txt</span>
file downloaded from the HutchColor website.<br>
<br>
For the Christophe Métairie's Digital TargeT 003 chart with 285
patches, the <span style="font-weight: bold;"><span
style="font-weight: bold;">ref/</span>CMP_DT_003.cht</span>
file
should be used, and the cie reference <span style="font-weight: bold;"></span>files
come
with
the
chart.<br>
<br>
For the Christophe Métairie's Digital Target-3 chart with 570
patches, the <span style="font-weight: bold;">ref/CMP_Digital_Target-3.cht</span>
file
should be used, and the cie reference <span style="font-weight: bold;"></span>files
come
with
the
chart.<br>
<br>
For the LaserSoft DCPro chart, the <span style="font-weight: bold;">ref/LaserSoftDCPro.cht</span>
file should be used, and reference <span style="font-weight: bold;">.txt</span>
file downloaded from the <a
href="http://www.silverfast.com/it8calibration/">Silverfast website</a>.
</div>
<br>
For any other type of chart, a
chart recognition template file will need to be created (this is beyond
the scope of the current documentation, although see the <a
href="cht_format.html">.cht_format documentation</a>).<br>
<br>
To create the scanner .ti3 file, run the <b>scanin</b> tool as
follows
(assuming an IT8 chart is being used):<br>
<br>
<a href="scanin.html"> scanin</a> -v scanner.tif It8.cht It8ref.txt<br>
<br>
"It8ref.txt" or "It8ref.cie" is assumed to be the name of the CIE
reference file
supplied by the chart manufacturer. The resulting file will be named "<b>scanner.ti3</b>".<br>
<br>
<span style="font-weight: bold;">scanin</span> will process 16 bit per
component .tiff files, which (if the scanner is capable of creating
such files), may improve the quality of the profile. <br>
<br>
If you have any doubts about the correctness of the chart recognition,
or the subsequent profile's delta E report is unusual, then use the
scanin diagnostic flags <a href="scanin.html#d">-dipn</a> and examine
the <span style="font-weight: bold;">diag.tif</span> diagnostic file,
to make sure that the patches are identified and aligned correctly. If
you have problems getting good automatic alignment, then consider doing
a manual alignment by locating the fiducial marks on your scan, and
feeding them into scanin <a href="scanin.html#F">-F</a> parameters.
The fiducial marks should be listed in a clockwise direction starting
at the top left.<br>
<h4><a name="PS4"></a>Creating a scanner or camera input profile</h4>
Similar to a display profile, an input profile can be either a
shaper/matrix or LUT based profile. Well behaved input devices will
probably give the best results
with a shaper/matrix profile, and this may also be the best choice if
your test chart has a small or unevenly distributed set of test patchs
(ie. the IT8.7.2). If a shaper/matrix profile is a poor fit, consider
using a
LUT
type profile.<br>
<br>
When creating a LUT type profile, there is the choice of XYZ or L*a*b*
PCS (Device independent, Profile Connection Space). Often for input
devices, it is better to choose the XYZ PCS, as this may be a better
fit given that input devices are usually close to being linearly
additive in behaviour.<br>
<br>
If the purpose of the input profile is to use it as a substitute for
a
colorimeter, then the <b>-u</b> flag should be used to avoid clipping
values above the white point. Unless the shaper/matrix type profile is
a very good fit, it is probably advisable to use a LUT type profile in
this situation.<br>
<br>
To create a matrix/shaper profile, the following suffices:<br>
<br>
<a href="colprof.html">colprof</a> <a href="colprof.html#v">-v</a> <a
href="colprof.html#E">-D"Scanner</a> <a href="colprof.html#E">A"</a> <a
href="colprof.html#q">-qm</a> <a href="colprof.html#a">-as</a>
<a href="colprof.html#p1">scanner</a><br>
<br>
For an XYZ PCS LUT based profile then the following would be used:<br>
<br>
<a href="colprof.html">colprof</a> <a href="colprof.html#v">-v</a> <a
href="colprof.html#E">-D"Scanner A"</a>
<a href="colprof.html#q">-qm</a>
<a href="colprof.html#a">-ax</a> <a href="colprof.html#p1">scanner</a><br>
<br>
For the purposes of a poor mans colorimeter, the following would
generally be used:<br>
<br>
<a href="colprof.html">colprof</a> <a href="colprof.html#v">-v</a> <a
href="colprof.html#E">-D"Scanner A"</a>
<a href="colprof.html#q">-qm</a> <a href="colprof.html#a">-ax</a>
<a href="colprof.html#u">-u</a>
<a href="colprof.html#p1">scanner</a><br>
<br>
Make sure you check the delta E report at the end of the profile
creation, to see if the profile is behaving reasonably.<br>
<br>
<br>
If profiling a <span style="font-weight: bold;">camera</span> in <span
style="font-weight: bold;">RAW</span> mode, then there may be some
advantage in creating a pure matrix only profile, in which it is
assumed that the camera response is completely linear. This may reduce
extrapolation artefacts. If setting the white point will be done in
some application, then it may also be an advantage to use the <span
style="font-weight: bold;">-u</span> flag and avoid setting the white
point to that of the profile chart:<br>
<br>
<a href="colprof.html">colprof</a> <a href="colprof.html#v">-v</a> <a
href="colprof.html#E">-D"Camera"</a>
<a href="colprof.html#q">-qm</a> <a href="colprof.html#a">-am</a>
<a href="colprof.html#u">-u</a>
<a href="colprof.html#p1">scanner</a><br>
<br>
<br>
<hr size="2" width="100%">
<h3><a name="PP1"></a>Profiling Printers<br>
</h3>
The overall process is to create a set of device measurement target
values, print them out, measure them, and then create an ICC profile
from the measurements. If the printer is an RGB based printer, then the
process is only slightly more complicated than profiling a display. If
the printer is CMYK based, then some additional parameters are required
to set the total ink limit (TAC) and black generation curve.<br>
<h4><a name="PP2"></a>Creating a print profile test chart</h4>
The first step in profiling any output device, is to create a set
of device colorspace test values. The important parameters needed are:<br>
<ul>
<li>What colorspace does the device use ?</li>
<li>How many test patches do I want to use/what paper size do I want
to use ?</li>
<li>What instrument am I going to use to read the patches ?<br>
</li>
<li>If it is a CMYK device, what is the total ink limit ?<br>
</li>
<li>What information do I already have about how the device behaves ?</li>
</ul>
Most printers running through simple drivers will appear as if they are
RGB devices. In fact there is no such
thing as a real RGB printer, since printers use white media and the
colorant must subtract from the light reflected on it to create color,
but the printer itself turns the incoming RGB into the native print
colorspace, so for this reason we will tell targen to use the
"Print RGB" colorspace, so that it knows that it's really a subtractive
media. Other drivers will drive a printer more directly, and will
expect a CMYK profile. [Currently Argyll is not capable of creating an
ICC profile for devices with more colorants than CMYK. When this
capability is introduced, it will by creating an additional separation
profile which then allows the printer to be treated as a CMY or CMYK
printer.] One way of telling what sort
of profile is expected for your device is to examine an existing
profile for
that device using <a href="http://www.argyllcms.com/doc/iccdump.html">iccdump</a>.<br>
<br>
The number of test patches will depend somewhat on what quality profile
you want to make, how well behaved the printer is, as well as the
effort needed to read the number of
test values. Generally it is convenient to fill a certain paper size
with the maximum
number of test values that will fit.<br>
<br>
At a minimum, for an "RGB" device, a few hundred values are needed
(400-1000).
For high quality CMYK profiles, 1000-3000 is not an unreasonable number
of
patches.<br>
<br>
To assist the determination of test patch values, it can help to have a
rough idea of how the device behaves, so that the device test point
locations can be pre-conditioned. This could be in the form of an
ICC profile of a similar device, or a lower quality, or previous
profile for that particular device. If one were going to make a very
high quality Lut based profile, then it might be worthwhile to make up
a smaller, preliminary shaper/matrix profile using a few hundred test
points, before embarking on testing the device with several thousand.<br>
<br>
The documentation for the <a
href="http://www.argyllcms.com/doc/targen.html">targen</a> tool
lists
a
<a href="http://www.argyllcms.com/doc/targen.html#Table">table</a> of
paper
sizes and number of patches for typical situations.<br>
<br>
For a CMYK device, a total ink limit usually needs to be specified.
Sometimes
a device will have a maximum total ink limit set by its manufacturer or
operator,
and some CMYK systems (such as chemical proofing systems) don't have
any
limit. Typical printing devices such as Xerographic printers, inkjet
printers
and printing presses will have a limit. The exact procedure for
determining an
ink limit is outside the scope of this document, but one way of going
about this might be to generate some small (say a few hundred patches)
with targen & pritntarg with different total ink limits, and
printing them out, making the ink limit as large as possible without
striking problems that are caused by too much ink.<br>
<br>
Generally one wants to use the maximum possible amount of ink to
maximize the gamut available on the device. For most CMYK devices, an
ink limit between 200 and 400 is usual, but and ink limit of 250% or
over is generally desirable for reasonably dense blacks and dark
saturated colors. And ink limit of less than 200% will begin to
compromise the fully saturated gamut, as secondary colors (ie
combinations of any two primary colorants) will not be able to reach
full strength.<br>
<br>
Once an ink limit is used in printing the characterization test chart
for a device, it becomes a critical parameter in knowing what the
characterized gamut of the device is. If after
printing the test chart, a greater ink limit were to be used, the the
software would effectively be extrapolating
the device behaviour at total ink levels beyond that used in the test
chart, leading to inaccuracies.<br>
<br>
Generally in Argyll, the ink limit is established when creating the
test chart values, and then carried through the profile making process
automatically. Once the profile has been made
however, the ink limit is no longer recorded, and you, the user, will
have to keep track of it if the ICC profile is used in any program than
needs to know the usable gamut of the device.<br>
<br>
<br>
Lets consider two devices in our examples, "PrinterA" which is an "RGB"
device, and "PrinterB" which is CMYK, and has a target ink limit of
250%.
<br>
<br>
The simplest approach is to make a set of test values that is
independent
of the characteristics of the particular device:<br>
<br>
<a href="targen.html">targen</a> <a href="targen.html#v">-v</a> <a
href="targen.html#d">-d2</a> <a href="targen.html#f">-f1053</a> <a
href="targen.html#p1">PrinterA</a><br>
<br>
<a href="targen.html">targen</a> <a href="targen.html#v">-v</a> <a
href="targen.html#d">-d4</a> <a href="targen.html#l">-l260</a> <a
href="targen.html#f">-f1053</a> <a href="targen.html#p1">PrinterB</a><br>
<br>
The number of patches chosen here happens to be right for an A4 paper
size being read using a Spectroscan instrument. See the <a
href="targen.html#Table">table</a> in the <a href="targen.html">targen</a>
documentation for some other suggested numbers.<br>
<br>
If there is a preliminary or previous profile called "OldPrinterA"
available, and we want to try creating a "pre-conditioned" set of test
values that will more efficiently sample the device response, then the
following would achieve this:<u><br>
</u><br>
<a href="targen.html">targen</a> <a href="targen.html#v">-v</a> <a
href="targen.html#d">-d2</a> <a href="targen.html#f">-f1053</a> <a
href="targen.html#c">-c OldPrinterA</a> <a href="targen.html#p1">PrinterA</a><br>
<br>
<a href="targen.html">targen</a> <a href="targen.html#v">-v</a> <a
href="targen.html#d">-d4</a> <a href="targen.html#l">-l260</a> <a
href="targen.html#f">-f1053</a> <a href="targen.html#c">-c OldPrinterB</a>
<a href="targen.html#p1">PrinterB</a><br>
<a href="targen.html#p1"></a><br>
<br>
The output of <b>targen</b> will be the file PrinterA.ti1 and
PrinterB.ti1 respectively, containing the device space test values, as
well as expected CIE values used for chart recognition purposes.<br>
<br>
<h4><a name="PP2b"></a>Printing a print profile test chart<br>
<br>
</h4>
The next step is turn the test values in to a PostScript or TIFF raster
test file that
can printed on the device. The basic information that needs to be
supplied is the type of instrument that will be used to read the
patches, as well as the paper size it is to be formatted for.<br>
<br>
For an X-Rite DTP41, the following would be typical:<br>
<br>
<a href="printtarg.html">printtarg</a> <a href="printtarg.html#v">-v</a>
<a href="printtarg.html#i">-i41</a> <a href="printtarg.html#p">-pA4</a>
<a href="printtarg.html#p1">PrinterA</a><br>
<br>
For a Gretag Eye-One Pro, the following would be typical:<br>
<br>
<a href="printtarg.html">printtarg</a> <a href="printtarg.html#v">-v</a>
<a href="printtarg.html#i">-ii1</a> <a href="printtarg.html#p">-pA4</a>
<a href="printtarg.html#p1">PrinterA</a><br>
<br>
For using with a scanner as a colorimeter, the Gretag Spectroscan
layout is suitable, but the <a href="printtarg.html#s">-s</a> flag
should be used so as to generate a layout suitable for scan
recognition, as well as generating the scan recognition template
files. (You probably want to use less patches with <span
style="font-weight: bold;">targen</span>, when using the <span
style="font-weight: bold;">printtarg -s</span> flag, e.g. 1026 patches
for an A4R page, etc.) The following would be typical:<br>
<br>
<a href="printtarg.html">printtarg</a> <a href="printtarg.html#v">-v</a>
<a href="printtarg.html#s">-s</a> <a href="printtarg.html#i">-iSS</a> <a
href="printtarg.html#p">-pA4R</a> <a href="printtarg.html#p1">PrinterA</a><br>
<span style="font-weight: bold;"><br>
printtarg</span> reads the
PrinterA.ti1
file, creates a PrinterA.ti2 file containing the layout information as
well as the device values and expected CIE values, as well as a
PrinterA.ps file containing the test chart. If the <span
style="font-weight: bold;">-s</span> flag is used, one or more
PrinterA.cht files is created to allow the <a href="scanin.html">scanin</a>
program to recognize the chart.<br>
<br>
To create TIFF raster files rather than PostScript, use the <a
href="printtarg.html#t"><span style="font-weight: bold;">-t</span></a>
flag.<br>
<br>
<span style="font-weight: bold;">GSview</span> is a good program to use
to check what the PostScript file will
look like, without actually printing it out. You could also use <span
style="font-weight: bold;">Photoshop</span> or <span
style="font-weight: bold;">ImageMagick</span> for this purpose.<br>
<br>
The last step is to print the chart out.<br>
<br>
Using a suitable PostScript or raster file printing program,
downloader, print the chart. If you are not using a TIFF test chart,
and you do not have a PostScript capable printer, then an interpreter
like GhostScript
or even Photoshop could be used to rasterize the file into something
that can be printed. Note that it is important that the PostScript
interpreter or TIFF printing application and printer configuration is
setup for a device profiling run, and that any sort of
color conversion of color correction be turned off so that the device
values in the PostScript or TIFF file are sent directly to the device.
If the device has a
calibration system, then it would be usual to have setup and calibrated
the device before starting the profiling run, and to apply calibration
to the chart values. If Photoshop was to be
used, then
either the chart needs to be a single page, or separate .eps or .tiff
files for
each page should be used, so that they can be converted and printed one
at a time (see the <a href="printtarg.html#e">-e</a> and <a
href="printtarg.html#t">-t</a> flags).<br>
<br>
<h4><a name="PP3"></a>Reading a print test chart using an instrument</h4>
Once the test chart has been printed, the color of the patches needs to
be read using a suitable instrument.<br>
<br>
Several different instruments are currently supported, some that need
to be used patch by patch, some read a strip at a time, and some read a
sheet at a time. See <a href="instruments.html">instruments</a> for a
current list.<br>
<br>
The instrument needs to be connected to your computer before running
the <a href="chartread.html">chartread</a> command. Both serial port
and USB connected Instruments are supported. A serial port to USB
adapter
might have to be used if your computer doesn't have any serial ports,
and you have a serial interface connected instrument.<br>
<br>
If you run <a href="chartread.html">chartread</a> so as to print out
its usage message (ie. by using a <span style="font-weight: bold;">-?</span>
or <span style="font-weight: bold;">--</span> flags), then it will
list any identified serial ports or USB connected instruments, and
their corresponding number for
the <a href="chartread.html#c">-c</a> option. By default, <a
href="chartread.html">chartread</a> will try to connect to the first
available USB instrument, or an instrument on the first serial port.<br>
<br>
The only arguments required is
to specify the basename of the .ti2 file. If a non-default serial port
is to be used, then the <span style="font-weight: bold;">-c</span>
option would also be specified.<br>
<br>
e.g. for a Spectroscan on the second port:<br>
<br>
<a href="chartread.html">chartread</a> <a href="chartread.html#c">-c2</a>
<a href="chartread.html#p1">PrinterA</a><br>
<br>
For a DTP41 to the default serial port:<br>
<br>
<a href="chartread.html">chartread</a><a href="chartread.html#i"></a>
<a href="chartread.html#p1">PrinterA</a><br>
<br>
<span style="font-weight: bold;">chartread</span> will interactively
prompt you through the process of reading each sheet or strip. See <a
href="chartread.html">chartread</a> for more details on the responses
for each type of instrument. Continue with <a href="Scenarios.html#PP5">Creating
a
printer
profile</a>.<br>
<br>
<h4><a name="PP4"></a>Reading a print test chart using a scanner or
camera<br>
</h4>
<br>
Argyll supports using a scanner or even a camera as a substitute for a
colorimeter.
While a scanner or camera is no replacement for a color measurement
instrument, it may give acceptable results in some situations, and may
give better results than a generic profile for a printing device.<br>
<br>
The main limitation of the scanner-as-colorimeter approach are:<br>
<br>
* The scanner dynamic range and/or precision may not match the printers
or what is required for a good profile.<br>
* The spectral interaction of the scanner test chart and printer test
chart with the scanner
spectral response can cause color errors.<br>
* Spectral differences caused by different black amounts in the print
test chart can cause
color errors. <br>
* The scanner reference chart gamut may be much smaller than the
printers gamut, making the scanner profile too inaccurate to be useful.
<br>
<br>
As well as some of the above, a camera may not be suitable if it
automatically adjusts exposure or white point when taking a picture,
and this behavior cannot be disabled.<br>
<br>
The end result is often a profile that has a noticeable color cast,
compared to a profile created using a colorimeter or spectrometer.<br>
<br>
<br>
It is assumed that you have created a scanner or camera profile
following the <a href="http://www.argyllcms.com/doc/Scenarios.html#PS1">procedure</a>
outline above. For best possible results it
is advisable to both profile the scanner or camera, and use it in
scanning the
printed test chart, in as "raw" mode as possible (i.e. using 16 bits
per component images, if the scanner or camera is
capable of doing so; not setting white or black points, using a fixed
exposure etc.). It is
generally advisable to create a LUT type input profile, and use the <a
href="http://www.argyllcms.com/doc/colprof.html#u">-u</a> flag to
avoid clipping scanned value whiter than the input calibration chart.<br>
<br>
Scan or photograph your printer chart (or charts) on the scanner or
camera previously profiled.
<big><span style="font-weight: bold;">The
scanner or camera must be configured and used exactly the same as it
was when it
was profiled.</span></big><br>
<br>
I will assume the resulting scan/photo input file is called <span
style="font-weight: bold;">PrinterB.tif</span> (or <span
style="font-weight: bold;">PrinterB1.tif</span>, <span
style="font-weight: bold;">PrinterB2.tif</span> etc. in the case of
multiple charts). As with profiling the scanner or camera, the raster
file need
only be roughly cropped so as to contain the test chart.<br>
<br>
The scanner recognition files
created when <span style="font-weight: bold;">printtarg</span> was run
is assumed to be called <span style="font-weight: bold;">PrinterB.cht</span>.
Using
the
scanner
profile
created previously (assumed to be called <span
style="font-weight: bold;">scanner.icm</span>), the printer test chart
scan patches are converted to CIE values using the <span
style="font-weight: bold;">scanin</span> tool:<br>
<br>
<a href="scanin.html">scanin</a> <a href="scanin.html#v">-v</a> <a
href="scanin.html#c">-c</a> <a href="scanin.html#cp1">PrinterB.tif</a>
<a href="scanin.html#cp2">PrinterB.cht</a> <a href="scanin.html#cp3">scanner.icm</a>
<a href="scanin.html#cp4">PrinterB</a><br>
<br>
If there were multiple test chart pages, the results would be
accumulated page by page using the <a href="scanin.html#ca">-ca</a>
option, ie., if there were 3 pages:<br>
<br>
<a href="scanin.html">scanin</a> <a href="scanin.html#v">-v</a> <a
href="scanin.html#c">-c</a> <a href="scanin.html#cp1">PrinterB1.tif</a>
<a href="scanin.html#cp2">PrinterB1.cht</a> <a href="scanin.html#cp3">scanner.icm</a>
<a href="scanin.html#cp4">PrinterB</a><br>
<a href="scanin.html">scanin</a> <a href="scanin.html#v">-v</a> <a
href="scanin.html#ca">-ca</a> <a href="scanin.html#cp1">PrinterB2.tif</a>
<a href="scanin.html#cp2">PrinterB2.cht</a> <a href="scanin.html#cp3">scanner.icm</a>
<a href="scanin.html#cp4">PrinterB</a><br>
<a href="scanin.html">scanin</a> <a href="scanin.html#v">-v</a> <a
href="scanin.html#ca">-ca</a> <a href="scanin.html#cp1">PrinterB3.tif</a>
<a href="scanin.html#cp2">PrinterB3.cht</a> <a href="scanin.html#cp3">scanner.icm</a>
<a href="scanin.html#cp4">PrinterB</a><br>
<br>
Now that the <span style="font-weight: bold;">PrinterB.ti3</span> data
has been obtained, the profile continue in the next section with <span
style="font-weight: bold;">Creating a printer profile</span>.<br>
<br>
If you have any doubts about the correctness of the chart recognition,
or the subsequent profile's delta E report is unusual, then use the
scanin diagnostic flags <a href="scanin.html#d">-dipn</a> and examine
the <span style="font-weight: bold;">diag.tif</span> diagnostic file.<br>
<h4><a name="PP5"></a>Creating a printer profile<br>
</h4>
Creating an RGB based printing profile is very similar to creating a
display device profile. For a CMYK printer, some additional information
is needed to set the black generation.<br>
<br>
Where the resulting profile will be used conventionally (ie. using <a
href="collink.html">collink</a> <a href="collink.html#s">-s</a>, or <a
href="cctiff.html">cctiff</a> or most
other "dumb" CMMs) it is important to specify that gamut mapping should
be computed for the output (B2A) perceptual and saturation tables. This
is done by specifying a device profile as the parameter to the <a
href="colprof.html">colprof</a> <a href="colprof.html#S">-S</a> flag.
When you intend to create a "general use" profile, it can be a good
technique to specify the source gamut as the opposite
type of profile to that being created, i.e. if a printer profile is
being
created, specify a display profile (e.g. sRGB) as the source gamut. If
a display profile is being created, then specify a printer profile as
the source
(e.g. SWOP). When linking to the profile you have created this
way as the output profile, then use perceptual intent if the source is
the opposite type, and relative colorimetric if it is the same type.<br>
<br>
"Opposite type of profile" refers to the native gamut of the device,
and what its fundamental nature is, additive or subtractive. An
emissive display will have additive primaries (R, G & B), while a
reflective print, will have subtractive primaries (C, M, Y &
possibly others), irrespective of what colorspace the printer is driven
in (a printer might present an RGB interface, but internally this will
be converted to CMY, and it will have a CMY type of gamut).
Because of the complimentary nature of additive and subtractive device
primary colorants, these types of devices have the most different
gamuts, and hence need the most gamut mapping to convert from one
colorspace to the other.<br>
<br>
If you are creating a profile for a specific purpose, intending to link
it to a specific input profile, then you will get the best results by
specifying that source profile as the source gamut.<br>
<br>
If a profile is only going to be used as an input profile, or is going
to be used with a "smart" CMM (e.g. <a href="collink.html">collink</a>
<a href="collink.html#g">-g</a> or <a href="collink.html#G">-G</a>),
then it can save considerable processing time and space if the -b flag
is used, and the -S flag not used.<br>
<br>
For an RGB printer intended to print RGB originals, the following might
be a typical profile usage:<br>
<br>
<a href="colprof.html">colprof</a> <a href="colprof.html#v">-v</a> <a
href="colprof.html#E">-D"Printer A"</a> <a href="colprof.html#q">-qm</a>
<a href="colprof.html#S">-S</a><a href="colprof.html#S"> sRGB.icm</a> <a
href="colprof.html#c">-cmt</a> <a href="colprof.html#d">-dpp</a>
<a href="colprof.html#p1">PrinterA</a><br>
<br>
or if you intent to print from SWOP style CMYK originals:<br>
<br>
<a href="colprof.html">colprof</a> <a href="colprof.html#v">-v</a> <a
href="colprof.html#E">-D"Printer A"</a> <a href="colprof.html#q">-qm</a>
<a href="colprof.html#S">-S</a><a href="colprof.html#S">
swop.icm</a> <a href="colprof.html#c">-cmt</a> <a
href="colprof.html#d">-dpp</a>
<a href="colprof.html#p1">PrinterA</a><br>
<br>
<h4><a name="PP6"></a>Choosing a black generation curve (and other CMYK
printer options)<br>
</h4>
For a CMYK printer, it would be normal to specify the type of black
generation, either as something simple, or as a specific curve. The
documentation in <a href="colprof.html#k">colprof</a> for the
details of the options.<span style="font-weight: bold;"><br>
<br>
Note</span> that making a good choice of black generation curve can
affect things such as: how robust neutrals are given printer drift or
changes in viewing lighting, how visible screening is, and how smooth
looking the B2A conversion is.<br>
<br>
For instance, maximizing the level of K will mean that the neutral
colors are composed of greater amounts of Black ink, and black ink
retains its neutral appearance irrespective of printer behavior or the
spectrum of the illuminant used to view the print. On the other hand,
output which is dominantly from one of the color channels will tend to
emphasize the screening pattern and any unevenness (banding etc.) of
that channel, and the black channel in particular has the highest
visibility. So in practice, some balance between the levels of the four
channels is probably best, with more K if the screening is fine and a
robust neutral balance is important, or less K if the screening is more
visible and neutral balance is less critical. The levels of K at the
edges of the gamut of the device will be fixed by the nature of the ink
combinations that maximize the gamut (ie. typically zero ink for light
chromatic colors, some combination for dark colors, and a high level of
black for very dark near neutrals), and it is also usually important to
set a curve that smoothly transitions to the K values at the gamut
edges. Dramatic changes in K imply equally dramatic changes in CMY, and
these abrupt transitions will reveal the limited precision and detail
that can be captured in a lookup table based profile, often resulting
in a "bumpy" looking output.<br>
<br>
If you want to experiment with the various
black
generation parameters, then it might be a good idea to create a
preliminary profile (using <a href="colprof.html#q">-ql</a> <a
href="colprof.html#b">-b</a> <a href="colprof.html#ni">-no</a>, <a
href="colprof.html#no">-ni</a> and
no <a href="colprof.html#S">-S</a>), and then used <a
href="xicclu.html#g">xicclu</a>
to explore the effect of the parameters.<br>
<br>
For instance, say we have our CMYK .ti3 file <span
style="font-weight: bold;">PrinterB.ti3</span>. First we make a
preliminary profile called <span style="font-weight: bold;">PrinterBt</span>:<br>
<br>
copy PrinterB.ti3 PrinterBt.ti3 (Use "cp"
on Linux or OSX of course.)<br>
<a href="colprof.html">colprof</a> <a href="colprof.html#v">-v</a> <a
href="colprof.html#q">-qm</a>
<a href="colprof.html#b">-b</a> <a href="colprof.html#c">-cmt</a>
<a href="colprof.html#d">-dpp</a>
<a href="colprof.html#p1">PrinterBt</a><br>
<br>
Then see what the minimum black level down the neutral axis can be.
Note that we need to also set any ink limits we've decided on as well
(coloprof defaulting to 10% less than the value recorded in the .ti3
file). In this example the test chart has a 300% total ink limit, and
we've decided to use 290%:<br>
<br>
<a href="xicclu.html">xicclu</a> <a href="xicclu.html#g">-g</a> <a
href="xicclu.html#k">-kz</a> <a href="xicclu.html#l">-l290</a> <a
href="xicclu.html#f">-fif</a> <a href="xicclu.html#i">-ir</a> <a
href="xicclu.html#p1">PrinterBt.icm</a><br>
<br>
Which might be a graph something like this:<br>
<br>
<img alt="Graph of CMYK neutral axis with minimum K" src="Kgraph1.jpg"
style="width: 250px; height: 250px;"><br>
<br>
Note how the minimum black is zero up to 93% of the
white->black L* curve, and then jumps up to 87%. This is because
we've reached
the total ink limit, and K then has to be substituted for CMY, to keep
the total under the total ink limit.<br>
<br>
Then let's see what the maximum black level down the neutral axis can
be:<br>
<br>
<a href="xicclu.html">xicclu</a> <a href="xicclu.html#g">-g</a> <a
href="xicclu.html#k">-kx</a> <a href="xicclu.html#l">-l290</a> <a
href="xicclu.html#f">-fif</a> <a href="xicclu.html#i">-ir</a> <a
href="xicclu.html#p1">PrinterBt.icm</a><br>
<br>
Which might be a graph something like this:<br>
<br>
<img alt="Graph of CMYK neutral axis with maximum K" src="Kgraph2.jpg"
style="width: 250px; height: 250px;"><br>
<br>
Note how the CMY values are fairly low up to 93% of the white->black
L* curve
(the low levels of CMY are helping set the neutral color), and then
they jump up.
This is because we've reach the point where black on it's own, isn't as
dark as the color that can be achieved using CMY and K. Because the K
has a dominant effect on the hue of the black, the levels of CMY are
often fairly volatile in this region.<br>
<br>
Any K curve we specify must lie between the black curves of the above
two graphs.<br>
<br>
Let's say we'd like to chose a moderate black curve, one that aims for
about equal levels of CMY and K. We should also aim for it to be fairly
smooth, since this will minimize visual artefacts caused by the limited
fidelity that profile LUT tables are able to represent inside the
profile.<br>
<br>
<img style="width: 340px; height: 258px;" alt="-k parameters"
src="Kparams.jpg"><br>
<br>
<br>
For minimum discontinuities we should aim for the curve to
finish at the point it has to reach to satisfy the total ink limit at
87% curve and 93% black. For a first try we can simply set a straight
line to that point: <br>
<br>
<a href="xicclu.html">xicclu</a> <a href="xicclu.html#g">-g</a> <a
href="xicclu.html#k">-kp 0 0 .93 .87 1.0</a> <a href="xicclu.html#l">-l290</a>
<a href="xicclu.html#f">-fif</a>
<a href="xicclu.html#i">-ir</a> <a href="xicclu.html#p1">PrinterBt.icm</a><br>
<br>
<img alt="Graph of CMYK neutral axis with kp 0 0 1.0 1.0 1.0 -l290"
src="Kgraph3.jpg" style="width: 250px; height: 250px;"><br>
<br>
The black "curve" hits the 93%/87% mark well, but is a bit too far
above CMY, so we'll try making the black curve concave:<br>
<br>
<a href="xicclu.html">xicclu</a> <a href="xicclu.html#g">-g</a> <a
href="xicclu.html#k">-kp </a><a href="xicclu.html#k">0 0 .93 .87 0.65</a>
<a href="xicclu.html#l">-l290</a>
<a href="xicclu.html#f">-fif</a>
<a href="xicclu.html#i">-ir</a> <a href="xicclu.html#p1">PrinterBt.icm</a><br>
<br>
<img alt="Graph of CMYK neutral axis with -kp 0 .05 1 .9 1 -l290"
src="Kgraph4.jpg" style="width: 250px; height: 249px;"><br>
<br>
This looks just about perfect, so the the curve parameters can now be
used to generate our real profile:<br>
<br>
<a href="colprof.html">colprof</a> <a href="colprof.html#v">-v</a> <a
href="colprof.html#E">-D"Printer B"</a> <a href="colprof.html#q">-qm</a>
<a href="colprof.html#k">-kp </a><a href="xicclu.html#k">0 0 .93 .87
0.65</a> <a href="colprof.html#S">-S</a><a href="colprof.html#S">
sRGB.icm</a> <a href="colprof.html#c">-cmt</a>
<a href="colprof.html#d">-dpp</a>
<a href="colprof.html#p1">PrinterB</a><br>
<br>
and the resulting B2A table black curve can be checked using xicclu:<br>
<br>
<a href="xicclu.html">xicclu</a> <a href="xicclu.html#g">-g</a> <a
href="xicclu.html#f">-fb</a>
<a href="xicclu.html#i">-ir</a> <a href="xicclu.html#p1">PrinterB.icm</a><br>
<br>
<img style="width: 250px; height: 250px;" alt="sadsadas"
src="Kgraph5.jpg"><br>
<br>
<br>
<hr
style="margin-left: 0px; margin-right: auto; width: 20%; height: 2px;"><br>
<span style="font-weight: bold;">Examples of other inkings:<br>
<br>
</span>A smoothed zero black inking:<br>
<br>
<a href="xicclu.html">xicclu</a> <a href="xicclu.html#g">-g</a> <a
href="xicclu.html#k">-kp </a><a href="xicclu.html#k">0 .7 .93 .87 1.0</a>
<a href="xicclu.html#l">-l290</a>
<a href="xicclu.html#f">-fif</a>
<a href="xicclu.html#i">-ir</a> <a href="xicclu.html#p1">PrinterBt.icm</a><br>
<br>
<img style="width: 250px; height: 250px;" alt="sadsadas"
src="Kgraph6.jpg"><br>
<br>
A low black inking:<br>
<br>
<a href="xicclu.html">xicclu</a> <a href="xicclu.html#g">-g</a> <a
href="xicclu.html#k">-kp </a><a href="xicclu.html#k">0 0 .93 .87 0.15</a>
<a href="xicclu.html#l">-l290</a>
<a href="xicclu.html#f">-fif</a>
<a href="xicclu.html#i">-ir</a> <a href="xicclu.html#p1">PrinterBt.icm</a><br>
<br>
<img style="width: 250px; height: 250px;" alt="sadsadas"
src="Kgraph7.jpg"><br>
<br>
<br>
A high black inking:<br>
<br>
<a href="xicclu.html">xicclu</a> <a href="xicclu.html#g">-g</a> <a
href="xicclu.html#k">-kp </a><a href="xicclu.html#k">0 0 .93 .87 1.2</a>
<a href="xicclu.html#l">-l290</a>
<a href="xicclu.html#f">-fif</a>
<a href="xicclu.html#i">-ir</a> <a href="xicclu.html#p1">PrinterBt.icm</a><br>
<br>
<img style="width: 250px; height: 250px;" alt="sadsadas"
src="Kgraph8.jpg"><br>
<br>
<span style="font-weight: bold;"></span>
<h4>Overriding the ink limit<br>
</h4>
Normally the total ink limit
will be read from the <span style="font-weight: bold;">PrinterB.ti3</span>
file, and will be set at a level 10% lower than the number used in
creating the test chart values using <a href="targen.html#l">targen -l</a>.
If
you
want
to
override this with a lower limit, then use the <a href="colprof.html#l">-l
flag</a>.<br>
<br>
<a href="colprof.html">colprof</a> <a href="colprof.html#v">-v</a> <a
href="colprof.html#E">-D"Printer B"</a> <a href="colprof.html#q">-qm</a>
<a href="colprof.html#S">-S</a><a href="colprof.html#S"> sRGB.icm</a> <a
href="colprof.html#c">-cmt</a> <a href="colprof.html#d">-dpp</a> <a
href="colprof.html#k">-kr</a>
<a href="xicclu.html#l">-l290</a> <a href="colprof.html#p1">PrinterB</a><br>
<br>
Make sure you check the delta E report at the end of the profile
creation, to see if the profile is behaving reasonably.<br>
<br>
One way of checking that your ink limit is not too high, is to use "<span
style="font-weight: bold;">xicc -fif -ia</span>" to check, by setting
different ink limits using the <span style="font-weight: bold;">-l</span>
option, feeding Lab = 0 0 0 into it, and checking the resulting
black point. Starting with the ink limit used with <span
style="font-weight: bold;">targen</span> for the test chart, reduce it
until the black point starts to be affected. If it is immediately
affected by any reduction in the ink limit, then the black point may be
improved by increasing the ink limit used to generate the test chart
and then re-print and re-measuring it, assuming
other aspects such as wetness, smudging, spreading or drying time are
not an issue.<br>
<br>
<hr style="width: 100%; height: 2px;"><br>
<h3><a name="PC1"></a>Calibrating Printers<br>
</h3>
<span style="font-weight: bold;">Profiling</span> creates a description
of how a device behaves, while <span style="font-weight: bold;">calibration</span>
on the other hand is
intended to <span style="text-decoration: underline;">change</span>
how a device behaves. Argyll has the ability to
create per-channel device space calibration curves for print devices,
that
can
then be used to improve the behavior of of the device, making a
subsequent
profile fit the device more easily and also allow day to day
correction of device drift without resorting to a full re-profile.<br>
<br>
<span style="font-weight: bold;">NOTE:</span> Because calibration adds
yet another layer to the way color is processed, it is recommended
that it not be attempted until the normal profiling workflow is
established,
understood and verified.<br>
<h4><a name="PC2"></a>Calibrated print workflows</h4>
There are two main workflows that printer calibration curves can be
applied to:<br>
<br>
<span style="text-decoration: underline;">Workflow <span
style="font-weight: bold;">with</span> native calibration capability</span>:<br>
<br>
Firstly the printer itself may have the capability of using per channel
calibration curves. In this situation, the calibration process will be
largely independent of profiling. Firstly the printer is configured to
have both its color management and calibration disabled (the latter
perhaps achieved by loading linear calibration curves), and a print
calibration test chart that consists of per channel color wedges is
printed. The calibration chart is read and the resulting .ti3 file
converted into calibration curves by
processing it using <span style="font-weight: bold;">printcal</span>.
The calibration is then installed into the printer. Subsequent
profiling will be performed on the <span
style="text-decoration: underline;">calibrated</span> printer (ie. the
profile
test chart will have the calibration curves applied to it by the
printer, and the resulting ICC profile will represent the behavior of
the calibrated printer.)<br>
<br>
<span style="text-decoration: underline;">Workflow <span
style="font-weight: bold;">without</span> native calibration capability</span>:<br>
<br>
The second workflow is one in which the printer has no calibration
capability itself. In this situation, the calibration process will have
to be applied using the ICC color management tools, so careful
coordination with profiling is needed. Firstly the printer is
configured to have its color management disabled, and a print
calibration test chart that consists
of per channel color wedges is printed. The calibration chart is
converted into calibration curves by reading it and then processing the
resultant .ti3 using <span style="font-weight: bold;">printcal</span>,.
During
the
subsequent
<span style="text-decoration: underline;">profiling</span>, the
calibration curves will need to be applied to the
profile test chart in the process of using <span
style="font-weight: bold;">printtarg</span>. Once the the profile has
been created, then in subsequent printing the calibration curves will
need to be applied to an image being printed either explicitly when
using <span style="font-weight: bold;">cctiff</span> to apply color
profiles <span style="text-decoration: underline;">and</span>
calibration, <span style="font-weight: bold;">OR</span>
by creating
a version of the profile that has had the calibration curves
incorporated into it using the <span style="font-weight: bold;">applycal</span>
tool. The latter is useful when some CMM (color management module)
other than <span style="font-weight: bold;">cctiff </span>is being
used.<br>
<br>
Once calibration aim targets for a particular device and mode
(screening,
paper etc.) have been established, then the printer can be
re-calibrated at any time to bring its per channel behavior back into
line if it drifts, and the new calibration curves can be installed into
the printer, or re-incorporated into the profile.
<h4><a name="PC3"></a>Creating a print calibration test chart</h4>
The first step is to create a print calibration test chart. Since
calibration only creates per-channel curves, only single channel step
wedges are required for the chart. The main choice is the number of
steps in each wedge. For simple fast calibrations perhaps as few as 20
steps per channel may be enough, but for a better quality of
calibration something like 50 or more steps would be a better choice.<br>
<br>
Let's consider two devices in our examples, "PrinterA" which is an
"RGB"
printer device, and "PrinterB" which is CMYK. In fact there is no such
thing as a real RGB printer, since printers use white media and the
colorant must subtract from the light reflected on it to create color,
but the printer itself turns the incoming RGB into the native print
colorspace, so for this reason we are careful to tell targen to use the
"Print RGB" colorspace, so that it knows to create step wedges from
media white to full colorant values.<br>
<br>
For instance, to create a 50 steps per channel calibration test chart
for our RGB and CMYK devices, the following would be sufficient:<br>
<br>
<a href="targen.html">targen</a> <a href="targen.html#v">-v</a> <a
href="targen.html#d">-d2</a> <a href="targen.html#s">-s50</a> <a
href="targen.html#e">-e3</a> <a href="targen.html#f">-f0</a> <a
href="targen.html#p1">PrinterA_c</a><br>
<br>
<a href="targen.html">targen</a> <a href="targen.html#v">-v</a> <a
href="targen.html#d">-d4</a> <a href="targen.html#s">-s50</a> <a
href="targen.html#e">-e4</a> <a href="targen.html#f">-f0</a> <a
href="targen.html#p1">PrinterB_c</a><br>
<a href="targen.html#p1"></a><br>
For an outline of how to then print and read the resulting test chart,
see <a href="Scenarios.html#PP2b">Printing a print profile test
chart</a>, and <a href="Scenarios.html#PP3">Reading a print test chart
using an instrument</a>. Note that the printer must be in an
un-profiled and un-calibrated mode when doing this print. Having done
this, there will be a PrinterA.ti3 or PrinterB.ti3 file
containing the step wedge calibration chart readings.<br>
<br>
<span style="font-weight: bold;">NOTE</span> that if you are
calibrating a raw printer driver, and there is considerable dot gain,
then you may want to use the <a href="targen.html#p">-p</a> parameter
to adjust the test chart point distribution to spread them more evenly
in perceptual space, giving more accurate control over the calibration.
Typically this will be a value greater than one for a device that has
dot gain, e.g. values of 1.5, 2.0 or 2.5 might be good places to start.<br>
<h4><a name="PC4"></a>Creating a printer calibration<br>
</h4>
The <a href="printcal.html">printcal</a> tool turns a calibration
chart <a href="File_Formats.html#.ti3">.ti3</a> file into a <a
href="File_Formats.html#.cal">.cal</a> file. It has three main
operating
modes:- Initial calibration, Re-Calibration, and Verification. (A
fourth mode, "Imitation" is very like Initial Calibration, but is used
for establishing a calibration target that a similar printer can
attempt to imitate.)<br>
<br>
The distinction between Initial Calibration and Re-Calibration is that
in the initial calibration we establish the "aim points" or response we
want out of the
printer after calibration. There are three basic parameters to set this
for each channel: Maximum level, minimum level, and curve shape.<br>
<br>
By default the maximum level will be set using a heuristic which
attempts to pick the point when there is diminishing returns for
applying more colorant. This can be overridden using the <span
style="font-weight: bold;">-x# percent</span> option, where <span
style="font-weight: bold;">#</span> represents the choice of channel
this will be applied to. The parameter is the percentage of device
maximum. <br>
<br>
The minimum level defaults to 0, but can be overridden using the <span
style="font-weight: bold;">-n# deltaE</span> option. A minimum of 0
means that zero colorant will correspond to the natural media color,
but it may be desirable to set a non-pure media color using calibration
for the purposes of emulating some other media. The parameter is in
Delta E units.<br>
<br>
The curve shape defaults to being perceptually uniform, which means
that even steps of calibrated device value result in perceptually even
color steps. In some situations it may be desirable to alter this curve
(for instance when non color managed output needs to be sent to the
calibrated printer), and a simple curve shape target can be set using
the <span style="font-weight: bold;">-t# percent</span> parameter.
This affects the output value at 50% input value, and represents the
percentage of perceptual output. By default it is 50% perceptual output
for 50% device input.<br>
<br>
Once a device has been calibrated, it can be re-calibrated to the same
aim target.<br>
<br>
Verification uses a calibration test chart printed through the
calibration, and compares the achieved response to the aim target.<br>
<br>
The simplest possible way of creating the <span
style="font-weight: bold;">PrinterA.cal</span> file is:<br>
<br>
<a href="printcal.html">printcal</a> <a href="printcal.html#i">-i</a> <a
href="colprof.html#p2">PrinterA_c</a><br>
<br>
For more detailed information, you can add the <span
style="font-weight: bold;">-v</span> and <span
style="font-weight: bold;">-p</span> flags:<br>
<br>
<a href="printcal.html">printcal</a> <a href="printcal.html#v">-v</a> <a
href="printcal.html#p">-p</a> <a href="printcal.html#i">-i</a> <a
href="colprof.html#p2">PrinterB_c</a><br>
<br>
(You will need to select the plot window and hit a key to advance past
each plot).<br>
<br>
For re-calibration, the name of the previous calibration file will need
to be supplied, and a new calibration<br>
file will be created:<br>
<br>
<a href="printcal.html">printcal</a> <a href="printcal.html#v">-v</a> <a
href="printcal.html#p">-p</a> <a href="printcal.html#r">-r</a> <a
href="colprof.html#p1">PrinterB_c_old</a> <a href="colprof.html#p2">PrinterB_c_new</a><br>
<br>
Various aim points are normally set automatically by <span
style="font-weight: bold;">printcal</span>, but these can be
overridden using the <a href="colprof.html#x">-x</a>, <a
href="colprof.html#n">-n</a> and <a href="colprof.html#t">-t</a>
options. e.g. say we wanted to set the maximum ink for Cyan to 80% and
Black to 95%, we might use:<br>
<br>
<a href="printcal.html">printcal</a> <a href="printcal.html#v">-v</a> <a
href="printcal.html#p">-p</a> <a href="printcal.html#i">-i</a> <a
href="colprof.html#x">-xc 80</a> <a href="colprof.html#x">-xk 95</a> <a
href="colprof.html#p2">PrinterB_c</a><br>
<br>
<a href="colprof.html#p2"></a>
<h4><a name="PC5"></a>Using a printer calibration</h4>
The resulting calibration curves can be used with the following other
Argyll tools:<br>
<br>
<a href="printtarg.html#K">printtarg</a>
To
apply
calibration
to
a profile test chart, and/or to have it
included in .ti3 file.<br>
<a href="cctiff.html#p2">cctiff</a>
To
apply
color
management
and calibration to an image file.<br>
<a href="applycal.html#p1">applycal</a>
To
incorporate
calibration
into
an ICC profile.<br>
<a href="chartread.html#I">chartread</a>
To
override
the
calibration
assumed when reading a profile chart.<br>
<br>
<br>
In a workflow <span style="font-weight: bold;">with</span> native
calibration capability, the calibration curves would be used with
printarg during subsequent <span style="font-weight: bold;">profiling</span>
so that any ink limit calculations will reflect final device values,
while not otherwise using the calibration within the ICC workflow:<br>
<br>
<a href="printtarg.html">printtarg</a> <a
href="printtarg.html#v">-v</a>
<a href="printtarg.html#i">-ii1</a> <a href="printtarg.html#p">-pA4</a>
<a href="printtarg.html#I">-I PrinterA_c.cal</a>
<a href="printtarg.html#p1">PrinterA</a><br>
<br>
This will cause the .ti2 and resulting .ti3 and ICC profiles to contain
the calibration curves, allowing all the tools to be able to compute
final device value ink limits. The calibration curves must also of
course be installed into the printer. The means to do this is currently
outside the scope of Argyll (ie. either the print system needs to be
able to understand Argyll CAL format files, or some tool will be
needed to convert Argyll CAL files into the printer calibration format).<br>
<br>
<br>
In a workflow <span style="font-weight: bold;">without</span> native
calibration capability, the calibration curves would be used with
printarg to <span style="text-decoration: underline;">apply</span> the
calibration to the test patch samples during subsequent <span
style="font-weight: bold;">profiling</span>, as well as embedding it
in the resulting .ti3 to allow all the tools to be able to compute
final device value ink limits:<br>
<br>
<a href="printtarg.html">printtarg</a> <a
href="printtarg.html#v">-v</a>
<a href="printtarg.html#i">-ii1</a> <a href="printtarg.html#p">-pA4</a>
<a href="printtarg.html#K">-K PrinterA_c.cal</a>
<a href="printtarg.html#p1">PrinterA</a><br>
<a href="cctiff.html#p4"></a><br>
To apply calibration to an ICC profile, so that a calibration unaware
CMM can be used:<br>
<br>
<a href="applycal.html">applycal</a> <a
href="applycal.html#p1">PrinterA.cal</a> <a href="applycal.html#p2">PrinterA.icm</a>
<a href="applycal.html#p3">PrinterA_cal.icm</a><br>
<br>
To apply color management and calibration to a raster image:<br>
<br>
<a href="cctiff.html">cctiff</a> <a
href="cctiff.html#p1">Source2Destination.icm</a>
<a href="cctiff.html#p2">PrinterA_c.cal</a>
<a href="cctiff.html#p3">infile.tif</a> <a href="cctiff.html#p4">outfile.tif</a><br>
<br>
<br>
Another useful tool is <a href="synthcal.html">synthcal</a>, that
allows creating linear or synthetic calibration files for disabling
calibration or testing.<br>
Similarly, <a href="fakeread.html">fakeread</a> also supports applying
calibration curves and embedding them in the resulting .ti3 file<br>
<h4><a name="PC6"></a>How profile ink limits are handled when
calibration is being used.</h4>
Even though the profiling process is carried out on top of the
linearized device, and the profiling is generally unaware of the
underlying non-linearized device values, an exception is made in the
calculation of ink limits during profiling. This is made possible
by including the calibration curves in the profile charts .ti2 and
subsequent .ti3 file and resulting ICC profile <span
style="font-weight: bold;">'targ'</span> text tag, by way of the <span
style="font-weight: bold;">printtarg</span> <span
style="font-weight: bold;">-I</span> or <span
style="font-weight: bold;">-K</span> options. This is done on the
assumption that the physical quantity of ink is what's important in
setting the ink limit, and that the underlying non-linearized device
values represent such a physical quantity.<br>
<br>
<br>
<hr size="2" width="100%">
<h3><a name="LP1"></a>Linking Profiles</h3>
Two device profiles can be linked together to create a device link
profile,
than encapsulates a particular device to device transform. Often this
step is not necessary, as many systems and tools will link two
device profiles "on the fly", but creating a device link profile gives
you the option of using "smart CMM" techniques, such as true gamut
mapping, improved inverse transform accuracy, tailored black
generation and
ink limiting.<br>
<br>
The overall process is to link the input space and
output space profiles using <a href="collink.html">collink</a>,
creating a device to device link profile. The device to device link
profile can then be used by cctiff (or other ICC device profile capable
tools), to color
correct a raster files.<br>
<br>
Three examples will be given here, showing the three different modes
than <span style="font-weight: bold;">collink</span> supports.<br>
<br>
In <a href="collink.html#s">simple mode</a>, the two profiles are
linked together in a similar fashion to other <span
style="font-weight: bold;">CMMs</span> simply using the forward and
backwards color transforms defined by the profiles. Any gamut mapping
is determined by the content of the tables within the two profiles,
together with the particular intent chosen. Typically the same intent
will be used for both the source and destination profile:<br>
<br>
<a href="collink.html">collink</a> <a href="collink.html#v">-v</a> <a
href="collink.html#q">-qm</a> <a href="collink.html#s">-s</a> <a
href="collink.html#si">-ip</a> <a href="collink.html#so">-op</a> <a
href="collink.html#p1">SouceProfile.icm</a> <a href="collink.html#p2">DestinationProfile.icm</a>
<a href="collink.html#p3">Source2Destination.icm</a><br>
<br>
<br>
In <a href="collink.html#g">gamut mapping mode</a>, the pre-computed
intent mappings inside the profiles are not used, but instead the gamut
mapping between source and destination is tailored to the specific
gamuts of the two profiles, and the intent parameter supplied to <span
style="font-weight: bold;">collink</span>. Additionally, source and
destination viewing conditions should be provided, to allow the color
appearance space conversion to work as intended. The colorimetric B2A
table in the destination profile is used, and this will determine any
black generation and ink limiting:<br>
<br>
<a href="collink.html">collink</a> <a href="collink.html#v">-v</a> <a
href="collink.html#q">-qm</a> <a href="collink.html#g">-g</a> <a
href="collink.html#si">-ip</a> <a href="collink.html#c">-cmt</a> <a
href="collink.html#d">-dpp</a> <a href="collink.html#p1">MonitorSouceProfile.icm</a>
<a href="collink.html#p2">DestinationProfile.icm</a>
<a href="collink.html#p3">Source2Destination.icm</a><br>
<br>
<br>
In <a href="collink.html#G">inverse output table gamut mapping mode</a>,
the
pre-computed
intent
mappings
inside the profiles are not used, but
instead the gamut mapping between source and destination is tailored to
the specific gamuts of the two profiles, and the intent parameter
supplied to <span style="font-weight: bold;">collink</span>. In
addition, the B2A table is <span style="font-weight: bold;">not</span>
used in the destination profile, but the
A2B table is instead inverted, leading to improved transform accuracy,
and in CMYK devices, allowing the ink limiting and black generation
parameters to be set:<br>
<br>
For a CLUT table based RGB printer destination profile, the following
would be appropriate:<br>
<br>
<a href="collink.html">collink</a> <a href="collink.html#v">-v</a> <a
href="collink.html#q">-qm</a> <a href="collink.html#G">-G</a> <a
href="collink.html#si">-ip</a> <a href="collink.html#c">-cmt</a> <a
href="collink.html#d">-dpp</a> <a href="collink.html#p1">MonitorSouceProfile.icm</a>
<a href="collink.html#p2">RGBDestinationProfile.icm</a>
<a href="collink.html#p3">Source2Destination.icm</a><br>
<br>
For a CMYK profile, the total ink limit needs to be specified (a
typical value being 10% less than the value used in creating the device
test chart), and the type of black generation also needs to be
specified:<br>
<br>
<a href="collink.html">collink</a> <a href="collink.html#v">-v</a> <a
href="collink.html#q">-qm</a> <a href="collink.html#G">-G</a> <a
href="collink.html#si">-ip</a> <a href="collink.html#c">-cmt</a> <a
href="collink.html#d">-dpp</a> <a href="collink.html#l">-l250</a> <a
href="collink.html#k">-kr</a> <a href="collink.html#p1">MonitorSouceProfile.icm</a>
<a href="collink.html#p2">CMYKDestinationProfile.icm</a>
<a href="collink.html#p3">Source2Destination.icm</a><br>
<br>
Note that you should set the source (<a href="collink.html#c">-c</a>)
and
destination (<a href="collink.html#d">-d</a>)
viewing conditions for the type of device the profile represents, and
the conditions under which it will be viewed.<br>
<br>
<h3><a name="LP2"></a>Soft Proofing Link</h3>
Often it is desirable to get an idea what a particular devices output
will look like using a different device. Typically this might be trying
to evaluate print output using a display. Often it is sufficient to use
an absolute or relative colorimetric transform from the print device
space to the display space, but while these provide a colorimetric
preview of the result, they do not take into account the subjective
appearance differences due to the different device conditions. It can
therefore be useful to create a soft proof appearance transform using
collink:<br>
<br>
<a href="collink.html">collink</a> <a href="collink.html#v">-v</a> <a
href="collink.html#q">-qm</a> <a href="collink.html#G">-G</a> <a
href="collink.html#si">-ila</a> <a href="collink.html#c">-cpp</a> <a
href="collink.html#d">-dmt</a> <a href="collink.html#l">-t250</a> <a
href="collink.html#k"></a><a href="collink.html#p1">CMYKDestinationProfile.icm</a>
<a href="collink.html#p2">MonitorProfile.icm</a> <a
href="collink.html#p3">SoftProof.icm</a><br>
<br>
We use the Luminance matched
appearance intent, to preserve the subjective apperance of the target
device, which takes into account the viewing conditions and assumes
adaptation to the differences in the luminence range, but otherwise not
attempting to compress or change the gamut.<br>
<hr size="2" width="100%"><br>
<h3><a name="TR1"></a>Transforming colorspaces of raster files</h3>
Although a device profile or device link profile may be useful with
other programs and systems, Argyll provides the tool <a
href="cctiff.html">cctiff</a> for directly applying a device to device
transform to a <a href="File_Formats.html#TIFF">TIFF</a> raster file.
The cctiff tool is capable of linking an arbitrary sequence of
device profiles, device links, abstract profiles and calibration
curves. Each device
profile can be preceded by the <span style="font-weight: bold;">-i</span>
option to indicate the intent that should be used. Both 8 and 16 bit
per component files
can be handled, and up to 8 color channels. The color transform is
optimized to perform the overall transformation rapidly.<br>
<br>
If a device link is to be used, the following is a typical example:<br>
<br>
<a href="cctiff.html">cctiff</a> <a href="cctiff.html#p1">Source2Destination.icm</a>
<a href="cctiff.html#p3">infile.tif</a> <a href="cctiff.html#p4">outfile.tif</a><br>
<br>
<i><br>
</i>If a source and destination profile are to be used, the following
would be a typical example:<br>
<br>
<a href="cctiff.html">
cctiff</a> <a href="cctiff.html#i">-ip</a> <a
href="cctiff.html#p1i">SourceProfile.icm</a>
<a href="cctiff.html#i">-ip</a> <a href="cctiff.html#p1o">DestinationProfile.icm</a>
<a href="cctiff.html#p3">infile.tif</a>
<a href="cctiff.html#p4">outfile.tif</a><br>
<br>