/usr/share/psychtoolbox-3/PsychCal/MeasMonXYZ.m is in psychtoolbox-3-common 3.0.11.20131230.dfsg1-1build1.
This file is owned by root:root, with mode 0o644.
The actual contents of the file can be viewed below.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 | function XYZ = MeasMonXYZ(window,settings,syncMode,whichMeterType)
% XYZ = MeasMonXYZ(window,settings,[syncMode],[whichMeterType])
%
% Measure the XYZ of a series of monitor settings.
%
% This routine is specific to go with CalibrateMon,
% as it depends on the action of SetMon.
%
% If whichMeterType is passed and set to 0, then the routine
% returns random spectra. This is useful for testing when
% you don't have a meter.
%
% Other valid types:
% 1 - Use PR650 (default)
%
% 10/26/93 dhb Wrote it based on ccc code.
% 11/12/93 dhb Modified to use SetColor.
% 6/23/94 ccc Modified it from MeasMonSpd.m for
% the purpose of measuring XYZ
% 8/9/94 dhb Added code to go into sync mode
% And then commented it out.
% 8/11/94 dhb Sync mode back in
% 8/15/94 dhb Sync mode as argument.
% 4/12/97 dhb New toolbox compatibility, take window and bits args.
% 8/26/97 dhb, pbe Add noMeterAvail option.
% 4/7/99 dhb Add argument for radius board. Compact default arg code.
% 8/14/00 dhb Call to CMETER('SetParams') conditional on OS9.
% 8/20/00 dhb Remove bits arg from call to SetColor.
% 8/21/00 dhb Remove dependence on RADIUS flag. This is now handled inside of SetColor.
% dhb Change calling conventions to remove unused args.
% 9/14/00 dhb Sync mode no longer used. Arg passed for backwards compatibility.
% 2/27/02 dhb, ly Pass whichMeterType rather than noMeterAvail.
% Check args and make sure window is passed right.
usageStr = 'XYZ = MeasMonXYZ(window,settings,[syncMode],[whichMeterType])';
if (nargin < 2 || nargin > 4 || nargout > 1)
error(usageStr);
end
if (size(window,1) ~= 1 || size(window,2) ~= 1)
error(usageStr);
end
% Set defaults
defaultSync = 0;
defaultWhichMeterType = 1;
% Check args and set defaults
if (nargin < 4 || isempty(whichMeterType))
whichMeterType = defaultWhichMeterType;
end
if (nargin < 3 || isempty(syncMode))
syncMode = defaultSync;
end
[null,nMeas] = size(settings);
XYZ = zeros(3,nMeas);
for i=1:nMeas
% Set color
SetColor(window,1,settings(:,i));
% Make the measurement
switch (whichMeterType)
case 0,
XYZ(:,i) = sum(settings(:,i)*ones(3,1);
WaitSecs(0.1);
case 1,
XYZ(:,i) = MeasXYZ;
otherwise,
error('Invalid meter type specified');
end
end
|