1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 | function BitValue=DaqDReadBit(daq,BitNumber)
% BitValue=DaqDReadBit(DeviceIndex,BitNumber)
% USB-1608FS: Write digital port. This command writes data to the DIO port
% bits that are configured as outputs.
% "DeviceIndex" is a small integer, the array index specifying which HID
% device in the array returned by PsychHID('Devices') is interface 0
% of the desired USB-1608FS box.
% "BitNumber" an integer from 0 to 8 specifying which bit to read
% See also Daq, DaqFunctions, DaqPins, DaqTest, PsychHIDTest.
% DaqDeviceIndex, DaqDIn, DaqDOut, DaqAIn, DaqAOut, DaqAInScan,DaqAOutScan.
%
% ******************************************************************************
% * *
% * If your Daq is a USB-1208FS or USB-1408FS, this code has not been tested; *
% * it probably will not run on your device. The USB-1608FS has only one DIO *
% * port and that is what this code was written to expect. To make it run on *
% * a 12 or 14 bit device, you should fix this to take an additional input *
% * (the portnumber) and to continue to behave as is for the 16-bit device. *
% * An example of how to do that can be found in DaqDConfigPort. -- mpr *
% * *
% ******************************************************************************
%
% I suspect that to get this code to work for a 1208FS or 1408FS you would have
% to modify the SetReport call to add the port number (0 or 1) before
% BitNumber. Hopefully that would be all it would take, but since I don't
% have one of those devices to test, I have not implemented that fix. Look at
% the code in DaqDOut to see how you might code something that tested for
% whether your Daq has two DIO ports, and how you'd handle input and report to
% accommodate the added port.
%
% BitNumber can be a vector so that you can read multiple bits at once.
%
% 12/xx/07 mpr scavenged code from DaqDIn and converted it to this.
% 1/11/08 mpr swept through attempting to improve consistency across daq
% functions
if length(BitNumber) > 1
BitValue = NaN*ones(1,length(BitNumber));
for k=1:length(BitNumber)
BitValue(k) = DaqDReadBit(daq,BitNumber(k));
end
return;
end
err=PsychHID('ReceiveReports',daq);
[reports,err]=PsychHID('GiveMeReports',daq);
err=PsychHID('SetReport',daq,2,5,uint8([5 BitNumber])); % DReadBit
if err.n
fprintf('DaqDReadBit SetReport error 0x%s. %s: %s\n',hexstr(err.n),err.name,err.description);
end
[report,err]=PsychHID('GetReport',daq,1,5,2); % Get report
if err.n
fprintf('DaqDReadBit GetReport error 0x%s. %s: %s\n',hexstr(err.n),err.name,err.description);
end
BitValue=double(report(2));
err=PsychHID('ReceiveReportsStop',daq);
return;
|