1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 | #!/usr/bin/env python
# -*- coding: utf-8 -*-
# Copyright (C) 2010-2012 Nik Lutz <nik.lutz@gmail.com>
#
# This program is free software; you can redistribute it and/or modify
# it under the terms of the GNU General Public License as published by
# the Free Software Foundation; either version 3 of the License, or
# (at your option) any later version.
#
# This program is distributed in the hope that it will be useful,
# but WITHOUT ANY WARRANTY; without even the implied warranty of
# MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
# GNU General Public License for more details.
#
# You should have received a copy of the GNU General Public License
# along with this program. If not, see <http://www.gnu.org/licenses/>.
import signal
import datetime
import dbus
import dbus.service
#from PyQt4.QtCore import QObject
#from PyQt4.QtCore import SIGNAL
#from PyQt4 import QtCore
from VeromixUtils import *
###
# Pass info/signals from PA to DBUS
###
class Pa2dBus():
def __init__(self, veromixdbus, pulseaudio):
self.dbus = veromixdbus
self.pulse = pulseaudio
self.LIMIT_SEND_METER_ENABLED = False
self.METER_SEND_MSECS = 100000 #micro
self.last_volume_meter_send = datetime.datetime.now()
self.last_source_meter_send = datetime.datetime.now()
# self.connect(self.pulse, SIGNAL("sink_info(PyQt_PyObject)"), self.on_sink_info)
# self.connect(self.pulse, SIGNAL("sink_remove(int)"), self.on_remove_sink)
# self.connect(self.pulse, SIGNAL("sink_input_info(PyQt_PyObject)"), self.on_sink_input_info)
# self.connect(self.pulse, SIGNAL("sink_input_remove(int)"), self.on_remove_sink_input)
# self.connect(self.pulse, SIGNAL("source_info(PyQt_PyObject)"), self.on_source_info)
# self.connect(self.pulse, SIGNAL("source_remove(int)"), self.on_remove_source)
# self.connect(self.pulse, SIGNAL("source_output_info(PyQt_PyObject)"), self.on_source_output_info)
# self.connect(self.pulse, SIGNAL("source_output_remove(int)"), self.on_remove_source_output)
# self.connect(self.pulse, SIGNAL("volume_meter_sink_input(int, float )"), self.on_volume_meter_sink_input)
# self.connect(self.pulse, SIGNAL("volume_meter_sink(int, float )"), self.on_volume_meter_sink)
# self.connect(self.pulse, SIGNAL("volume_meter_source(int, float )"), self.on_volume_meter_source)
# self.connect(self.pulse, SIGNAL("card_info(PyQt_PyObject)"), self.on_card_info)
# self.connect(self.pulse, SIGNAL("card_remove(int)"), self.on_remove_card)
# self.connect(self.pulse, SIGNAL("module_info(int, PyQt_PyObject, PyQt_PyObject, PyQt_PyObject, PyQt_PyObject)"), self.on_module_info)
def on_source_info(self, sink):
index = int(sink.index)
name = in_unicode(sink.name)
muted = (sink.mute == 1)
volume = sink.volume.getVolumes()
active_port = sink.active_port
ports = sink.ports
props = sink.propDict()
if "device.class" in props.keys() and props["device.class"] == "monitor":
return
self.dbus.source_info(index, name, muted, volume, props, ports, active_port)
def on_source_output_info(self, sink):
index = int(sink.index)
name = in_unicode(sink.name)
if sink.resample_method != "peaks":
self.dbus.source_output_info(index, name, sink.propDict())
def on_sink_input_info(self, sink):
index = int(sink.index)
name = in_unicode(sink.name)
muted = (sink.mute == 1)
volume = sink.volume.getVolumes()
self.dbus.sink_input_info(index, name, muted, volume, sink.propDict())
def on_sink_info(self, sink):
index = int(sink.index)
name = in_unicode(sink.name)
muted = (sink.mute == 1)
volume = sink.volume.getVolumes()
self.dbus.sink_info(index, name, muted, volume, sink.propDict(), sink.ports, sink.active_port)
def on_card_info(self, card_info):
self.dbus.card_info(card_info.index, card_info.name, card_info.properties(), card_info.active_profile_name(), card_info.profiles_dict())
def on_remove_card(self, index):
self.dbus.card_remove(index)
def on_remove_sink(self, index):
self.dbus.sink_remove(index)
def on_remove_sink_input(self, index):
self.dbus.sink_input_remove(index)
def on_remove_source(self, index):
self.dbus.source_remove(int(index))
def on_remove_source_output(self, index):
self.dbus.source_output_remove(int(index))
def on_volume_meter_sink_input(self, index, level):
if level == level:
if self.LIMIT_SEND_METER_ENABLED:
now = datetime.datetime.now()
# FIXME limit dbus spam but this solution could always prevent the same source from transmitting
if (now - self.last_volume_meter_send).microseconds > self.METER_SEND_MSECS :
self.last_volume_meter_send = now
self.dbus.volume_meter_sink_input(int(index),level)
else:
self.dbus.volume_meter_sink_input(int(index),level)
def on_volume_meter_sink(self, index, level):
if level == level:
if self.LIMIT_SEND_METER_ENABLED:
now = datetime.datetime.now()
# FIXME limit dbus spam but this solution could always prevent the same source from transmitting
if (now - self.last_volume_meter_send).microseconds > self.METER_SEND_MSECS :
self.last_volume_meter_send = now
self.dbus.volume_meter_sink(int(index),level)
else:
self.dbus.volume_meter_sink(int(index),level)
def on_volume_meter_source(self, index, level):
if level == level:
if self.LIMIT_SEND_METER_ENABLED:
now = datetime.datetime.now()
# FIXME limit dbus spam but this solution could always prevent the same source from transmitting
if (now - self.last_source_meter_send).microseconds > self.METER_SEND_MSECS :
self.last_source_meter_send = now
self.dbus.volume_meter_source(int(index),level)
else:
self.dbus.volume_meter_source(int(index),level)
def on_module_info(self, index, name, argument, n_used, auto_unload):