/usr/lib/python2.7/dist-packages/os_win/utils/compute/vmutils.py is in python-os-win 0.4.1-2.
This file is owned by root:root, with mode 0o644.
The actual contents of the file can be viewed below.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 384 385 386 387 388 389 390 391 392 393 394 395 396 397 398 399 400 401 402 403 404 405 406 407 408 409 410 411 412 413 414 415 416 417 418 419 420 421 422 423 424 425 426 427 428 429 430 431 432 433 434 435 436 437 438 439 440 441 442 443 444 445 446 447 448 449 450 451 452 453 454 455 456 457 458 459 460 461 462 463 464 465 466 467 468 469 470 471 472 473 474 475 476 477 478 479 480 481 482 483 484 485 486 487 488 489 490 491 492 493 494 495 496 497 498 499 500 501 502 503 504 505 506 507 508 509 510 511 512 513 514 515 516 517 518 519 520 521 522 523 524 525 526 527 528 529 530 531 532 533 534 535 536 537 538 539 540 541 542 543 544 545 546 547 548 549 550 551 552 553 554 555 556 557 558 559 560 561 562 563 564 565 566 567 568 569 570 571 572 573 574 575 576 577 578 579 580 581 582 583 584 585 586 587 588 589 590 591 592 593 594 595 596 597 598 599 600 601 602 603 604 605 606 607 608 609 610 611 612 613 614 615 616 617 618 619 620 621 622 623 624 625 626 627 628 629 630 631 632 633 634 635 636 637 638 639 640 641 642 643 644 645 646 647 648 649 650 651 652 653 654 655 656 657 658 659 660 661 662 663 664 665 666 667 668 669 670 671 672 673 674 675 676 677 678 679 680 681 682 683 684 685 686 687 688 689 690 691 692 693 694 695 696 697 698 699 700 701 702 703 704 705 706 707 708 709 710 711 712 713 714 715 716 717 718 719 720 721 722 723 724 725 726 727 728 729 730 731 732 733 734 735 736 737 738 739 740 741 742 743 744 745 746 747 748 749 750 751 752 753 754 755 756 757 758 759 760 761 762 763 764 765 766 767 768 769 770 771 772 773 774 775 776 777 778 779 780 781 782 783 784 785 786 787 788 789 790 791 792 793 794 795 796 797 798 799 800 801 802 803 804 805 806 807 808 809 810 811 812 813 814 815 816 817 818 819 820 821 822 823 824 825 826 827 828 829 830 831 832 833 834 835 836 837 838 839 840 841 842 843 844 845 846 847 848 849 850 851 852 853 854 855 856 857 858 859 860 861 862 863 864 865 866 867 868 869 870 871 872 873 874 875 876 877 878 879 880 881 882 883 884 885 886 887 888 889 890 891 892 893 894 895 896 897 898 899 900 901 902 903 904 905 906 907 908 909 910 911 912 913 914 915 916 917 918 919 920 921 922 923 924 925 926 927 928 929 930 931 932 933 934 935 936 937 938 939 940 941 942 943 944 945 946 947 948 949 950 951 952 953 954 955 956 957 958 959 960 961 962 963 964 965 966 967 968 969 970 971 972 973 974 975 976 977 978 979 980 981 982 983 984 985 986 987 988 989 990 991 992 993 994 995 996 997 998 999 1000 1001 1002 1003 1004 1005 1006 1007 1008 1009 1010 1011 1012 1013 1014 1015 1016 1017 1018 1019 1020 1021 1022 1023 1024 1025 1026 1027 1028 1029 1030 1031 1032 1033 1034 1035 1036 1037 1038 1039 1040 1041 1042 1043 1044 1045 1046 1047 1048 1049 1050 1051 1052 1053 | # Copyright (c) 2010 Cloud.com, Inc
# Copyright 2012 Cloudbase Solutions Srl / Pedro Navarro Perez
# All Rights Reserved.
#
# Licensed under the Apache License, Version 2.0 (the "License"); you may
# not use this file except in compliance with the License. You may obtain
# a copy of the License at
#
# http://www.apache.org/licenses/LICENSE-2.0
#
# Unless required by applicable law or agreed to in writing, software
# distributed under the License is distributed on an "AS IS" BASIS, WITHOUT
# WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. See the
# License for the specific language governing permissions and limitations
# under the License.
"""
Utility class for VM related operations.
Based on the "root/virtualization/v2" namespace available starting with
Hyper-V Server / Windows Server 2012.
"""
import sys
import time
import uuid
if sys.platform == 'win32':
import wmi
from oslo_config import cfg
from oslo_log import log as logging
from oslo_utils import uuidutils
import six
from six.moves import range # noqa
from os_win._i18n import _, _LE, _LW
from os_win import _utils
from os_win import constants
from os_win import exceptions
from os_win.utils import _wqlutils
from os_win.utils import baseutils
from os_win.utils import jobutils
from os_win.utils import pathutils
CONF = cfg.CONF
LOG = logging.getLogger(__name__)
class VMUtils(baseutils.BaseUtilsVirt):
# These constants can be overridden by inherited classes
_PHYS_DISK_RES_SUB_TYPE = 'Microsoft:Hyper-V:Physical Disk Drive'
_DISK_DRIVE_RES_SUB_TYPE = 'Microsoft:Hyper-V:Synthetic Disk Drive'
_DVD_DRIVE_RES_SUB_TYPE = 'Microsoft:Hyper-V:Synthetic DVD Drive'
_HARD_DISK_RES_SUB_TYPE = 'Microsoft:Hyper-V:Virtual Hard Disk'
_DVD_DISK_RES_SUB_TYPE = 'Microsoft:Hyper-V:Virtual CD/DVD Disk'
_IDE_CTRL_RES_SUB_TYPE = 'Microsoft:Hyper-V:Emulated IDE Controller'
_SCSI_CTRL_RES_SUB_TYPE = 'Microsoft:Hyper-V:Synthetic SCSI Controller'
_SERIAL_PORT_RES_SUB_TYPE = 'Microsoft:Hyper-V:Serial Port'
_SETTINGS_DEFINE_STATE_CLASS = 'Msvm_SettingsDefineState'
_VIRTUAL_SYSTEM_SETTING_DATA_CLASS = 'Msvm_VirtualSystemSettingData'
_RESOURCE_ALLOC_SETTING_DATA_CLASS = 'Msvm_ResourceAllocationSettingData'
_PROCESSOR_SETTING_DATA_CLASS = 'Msvm_ProcessorSettingData'
_MEMORY_SETTING_DATA_CLASS = 'Msvm_MemorySettingData'
_SERIAL_PORT_SETTING_DATA_CLASS = _RESOURCE_ALLOC_SETTING_DATA_CLASS
_STORAGE_ALLOC_SETTING_DATA_CLASS = 'Msvm_StorageAllocationSettingData'
_SYNTHETIC_ETHERNET_PORT_SETTING_DATA_CLASS = (
'Msvm_SyntheticEthernetPortSettingData')
_AFFECTED_JOB_ELEMENT_CLASS = "Msvm_AffectedJobElement"
_CIM_RES_ALLOC_SETTING_DATA_CLASS = 'Cim_ResourceAllocationSettingData'
_COMPUTER_SYSTEM_CLASS = "Msvm_ComputerSystem"
_LOGICAL_IDENTITY_CLASS = 'Msvm_LogicalIdentity'
_S3_DISP_CTRL_RES_SUB_TYPE = 'Microsoft:Hyper-V:S3 Display Controller'
_SYNTH_DISP_CTRL_RES_SUB_TYPE = ('Microsoft:Hyper-V:Synthetic Display '
'Controller')
_SYNTH_3D_DISP_CTRL_RES_SUB_TYPE = ('Microsoft:Hyper-V:Synthetic 3D '
'Display Controller')
_SYNTH_3D_DISP_ALLOCATION_SETTING_DATA_CLASS = (
'Msvm_Synthetic3DDisplayControllerSettingData')
_VIRTUAL_SYSTEM_SUBTYPE = 'VirtualSystemSubType'
_VIRTUAL_SYSTEM_TYPE_REALIZED = 'Microsoft:Hyper-V:System:Realized'
_VIRTUAL_SYSTEM_SUBTYPE_GEN2 = 'Microsoft:Hyper-V:SubType:2'
_SNAPSHOT_FULL = 2
_VM_ENABLED_STATE_PROP = "EnabledState"
_SHUTDOWN_COMPONENT = "Msvm_ShutdownComponent"
_VIRTUAL_SYSTEM_CURRENT_SETTINGS = 3
_AUTOMATIC_STARTUP_ACTION_NONE = 2
_remote_fx_res_map = {
constants.REMOTEFX_MAX_RES_1024x768: 0,
constants.REMOTEFX_MAX_RES_1280x1024: 1,
constants.REMOTEFX_MAX_RES_1600x1200: 2,
constants.REMOTEFX_MAX_RES_1920x1200: 3,
constants.REMOTEFX_MAX_RES_2560x1600: 4
}
_remotefx_max_monitors_map = {
# defines the maximum number of monitors for a given
# resolution
constants.REMOTEFX_MAX_RES_1024x768: 4,
constants.REMOTEFX_MAX_RES_1280x1024: 4,
constants.REMOTEFX_MAX_RES_1600x1200: 3,
constants.REMOTEFX_MAX_RES_1920x1200: 2,
constants.REMOTEFX_MAX_RES_2560x1600: 1
}
_DISP_CTRL_ADDRESS_DX_11 = "02C1,00000000,01"
_vm_power_states_map = {constants.HYPERV_VM_STATE_ENABLED: 2,
constants.HYPERV_VM_STATE_DISABLED: 3,
constants.HYPERV_VM_STATE_SHUTTING_DOWN: 4,
constants.HYPERV_VM_STATE_REBOOT: 11,
constants.HYPERV_VM_STATE_PAUSED: 9,
constants.HYPERV_VM_STATE_SUSPENDED: 6}
_DEFAULT_EVENT_CHECK_TIMEFRAME = 60 # seconds
_DEFAULT_EVENT_TIMEOUT_MS = 2000
def __init__(self, host='.'):
super(VMUtils, self).__init__(host)
self._jobutils = jobutils.JobUtils()
self._pathutils = pathutils.PathUtils()
self._enabled_states_map = {v: k for k, v in
six.iteritems(self._vm_power_states_map)}
def list_instance_notes(self):
instance_notes = []
for vs in self._conn.Msvm_VirtualSystemSettingData(
['ElementName', 'Notes'],
VirtualSystemType=self._VIRTUAL_SYSTEM_TYPE_REALIZED):
if vs.Notes is not None:
instance_notes.append(
(vs.ElementName, [v for v in vs.Notes if v]))
return instance_notes
def list_instances(self):
"""Return the names of all the instances known to Hyper-V."""
return [v.ElementName for v in
self._conn.Msvm_VirtualSystemSettingData(
['ElementName'],
VirtualSystemType=self._VIRTUAL_SYSTEM_TYPE_REALIZED)]
def get_vm_summary_info(self, vm_name):
vmsettings = self._lookup_vm_check(vm_name)
settings_paths = [vmsettings.path_()]
# See http://msdn.microsoft.com/en-us/library/cc160706%28VS.85%29.aspx
(ret_val, summary_info) = self._vs_man_svc.GetSummaryInformation(
[constants.VM_SUMMARY_NUM_PROCS,
constants.VM_SUMMARY_ENABLED_STATE,
constants.VM_SUMMARY_MEMORY_USAGE,
constants.VM_SUMMARY_UPTIME],
settings_paths)
if ret_val:
raise exceptions.HyperVException(
_('Cannot get VM summary data for: %s') % vm_name)
si = summary_info[0]
memory_usage = None
if si.MemoryUsage is not None:
memory_usage = int(si.MemoryUsage)
up_time = None
if si.UpTime is not None:
up_time = int(si.UpTime)
# Nova requires a valid state to be returned. Hyper-V has more
# states than Nova, typically intermediate ones and since there is
# no direct mapping for those, ENABLED is the only reasonable option
# considering that in all the non mappable states the instance
# is running.
enabled_state = self._enabled_states_map.get(si.EnabledState,
constants.HYPERV_VM_STATE_ENABLED)
summary_info_dict = {'NumberOfProcessors': si.NumberOfProcessors,
'EnabledState': enabled_state,
'MemoryUsage': memory_usage,
'UpTime': up_time}
return summary_info_dict
def get_vm_state(self, vm_name):
settings = self.get_vm_summary_info(vm_name)
return settings['EnabledState']
def _lookup_vm_check(self, vm_name, as_vssd=True, for_update=False):
vm = self._lookup_vm(vm_name, as_vssd, for_update)
if not vm:
raise exceptions.HyperVVMNotFoundException(vm_name=vm_name)
return vm
def _lookup_vm(self, vm_name, as_vssd=True, for_update=False):
if as_vssd:
conn = self._compat_conn if for_update else self._conn
vms = conn.Msvm_VirtualSystemSettingData(
ElementName=vm_name,
VirtualSystemType=self._VIRTUAL_SYSTEM_TYPE_REALIZED)
else:
vms = self._conn.Msvm_ComputerSystem(ElementName=vm_name)
n = len(vms)
if n == 0:
return None
elif n > 1:
raise exceptions.HyperVException(
_('Duplicate VM name found: %s') % vm_name)
else:
return vms[0]
def vm_exists(self, vm_name):
return self._lookup_vm(vm_name) is not None
def get_vm_id(self, vm_name):
vm = self._lookup_vm_check(vm_name, as_vssd=False)
return vm.Name
def _set_vm_memory(self, vmsetting, memory_mb, memory_per_numa_node,
dynamic_memory_ratio):
mem_settings = _wqlutils.get_element_associated_class(
self._compat_conn, self._MEMORY_SETTING_DATA_CLASS,
element_instance_id=vmsetting.InstanceID)[0]
max_mem = int(memory_mb)
mem_settings.Limit = max_mem
if dynamic_memory_ratio > 1:
mem_settings.DynamicMemoryEnabled = True
# Must be a multiple of 2
reserved_mem = min(
int(max_mem / dynamic_memory_ratio) >> 1 << 1,
max_mem)
else:
mem_settings.DynamicMemoryEnabled = False
reserved_mem = max_mem
mem_settings.Reservation = reserved_mem
# Start with the minimum memory
mem_settings.VirtualQuantity = reserved_mem
if memory_per_numa_node:
# One memory block is 1 MB.
mem_settings.MaxMemoryBlocksPerNumaNode = memory_per_numa_node
self._jobutils.modify_virt_resource(mem_settings)
def _set_vm_vcpus(self, vmsetting, vcpus_num, vcpus_per_numa_node,
limit_cpu_features):
procsetting = _wqlutils.get_element_associated_class(
self._compat_conn, self._PROCESSOR_SETTING_DATA_CLASS,
element_instance_id=vmsetting.InstanceID)[0]
vcpus = int(vcpus_num)
procsetting.VirtualQuantity = vcpus
procsetting.Reservation = vcpus
procsetting.Limit = 100000 # static assignment to 100%
procsetting.LimitProcessorFeatures = limit_cpu_features
if vcpus_per_numa_node:
procsetting.MaxProcessorsPerNumaNode = vcpus_per_numa_node
self._jobutils.modify_virt_resource(procsetting)
def update_vm(self, vm_name, memory_mb, memory_per_numa_node, vcpus_num,
vcpus_per_numa_node, limit_cpu_features, dynamic_mem_ratio):
vmsetting = self._lookup_vm_check(vm_name)
self._set_vm_memory(vmsetting, memory_mb, memory_per_numa_node,
dynamic_mem_ratio)
self._set_vm_vcpus(vmsetting, vcpus_num, vcpus_per_numa_node,
limit_cpu_features)
def check_admin_permissions(self):
if not self._compat_conn.Msvm_VirtualSystemManagementService():
raise exceptions.HyperVAuthorizationException()
def create_vm(self, *args, **kwargs):
# TODO(claudiub): method signature changed. Fix this when the usage
# for this method was updated.
# update_vm should be called in order to set VM's memory and vCPUs.
try:
self._create_vm(*args, **kwargs)
except TypeError:
# the method call was updated to use the _vnuma_create_vm interface
self._vnuma_create_vm(*args, **kwargs)
def _vnuma_create_vm(self, vm_name, vnuma_enabled, vm_gen, instance_path,
notes=None):
LOG.debug('Creating VM %s', vm_name)
self._create_vm_obj(vm_name, vnuma_enabled, vm_gen, notes,
instance_path)
def _create_vm(self, vm_name, memory_mb, vcpus_num, limit_cpu_features,
dynamic_memory_ratio, vm_gen, instance_path, notes=None):
"""Creates a VM."""
LOG.debug('Creating VM %s', vm_name)
# vNUMA and dynamic memory are mutually exclusive
vnuma_enabled = False if dynamic_memory_ratio > 1 else True
self._create_vm_obj(vm_name, vnuma_enabled, vm_gen, notes,
instance_path)
vmsetting = self._lookup_vm_check(vm_name)
LOG.debug('Setting memory for vm %s', vm_name)
self._set_vm_memory(vmsetting, memory_mb, None, dynamic_memory_ratio)
LOG.debug('Set vCPUs for vm %s', vm_name)
self._set_vm_vcpus(vmsetting, vcpus_num, None, limit_cpu_features)
def _create_vm_obj(self, vm_name, vnuma_enabled, vm_gen, notes,
instance_path):
vs_data = self._compat_conn.Msvm_VirtualSystemSettingData.new()
vs_data.ElementName = vm_name
vs_data.Notes = notes
# Don't start automatically on host boot
vs_data.AutomaticStartupAction = self._AUTOMATIC_STARTUP_ACTION_NONE
vs_data.VirtualNumaEnabled = vnuma_enabled
if vm_gen == constants.VM_GEN_2:
vs_data.VirtualSystemSubType = self._VIRTUAL_SYSTEM_SUBTYPE_GEN2
vs_data.SecureBootEnabled = False
# Created VMs must have their *DataRoot paths in the same location as
# the instances' path.
vs_data.ConfigurationDataRoot = instance_path
vs_data.LogDataRoot = instance_path
vs_data.SnapshotDataRoot = instance_path
vs_data.SuspendDataRoot = instance_path
vs_data.SwapFileDataRoot = instance_path
(job_path,
vm_path,
ret_val) = self._vs_man_svc.DefineSystem(
ResourceSettings=[], ReferenceConfiguration=None,
SystemSettings=vs_data.GetText_(1))
self._jobutils.check_ret_val(ret_val, job_path)
@_utils.retry_decorator(exceptions=exceptions.HyperVException)
def _modify_virtual_system(self, vmsetting):
(job_path, ret_val) = self._vs_man_svc.ModifySystemSettings(
SystemSettings=vmsetting.GetText_(1))
self._jobutils.check_ret_val(ret_val, job_path)
def get_vm_scsi_controller(self, vm_name):
vmsettings = self._lookup_vm_check(vm_name)
return self._get_vm_scsi_controller(vmsettings)
def _get_vm_scsi_controller(self, vmsettings):
rasds = _wqlutils.get_element_associated_class(
self._conn, self._RESOURCE_ALLOC_SETTING_DATA_CLASS,
element_instance_id=vmsettings.InstanceID)
res = [r for r in rasds
if r.ResourceSubType == self._SCSI_CTRL_RES_SUB_TYPE][0]
return res.path_()
def _get_vm_ide_controller(self, vmsettings, ctrller_addr):
rasds = _wqlutils.get_element_associated_class(
self._conn, self._RESOURCE_ALLOC_SETTING_DATA_CLASS,
element_instance_id=vmsettings.InstanceID)
ide_ctrls = [r for r in rasds
if r.ResourceSubType == self._IDE_CTRL_RES_SUB_TYPE
and r.Address == str(ctrller_addr)]
return ide_ctrls[0].path_() if ide_ctrls else None
def get_vm_ide_controller(self, vm_name, ctrller_addr):
vmsettings = self._lookup_vm_check(vm_name)
return self._get_vm_ide_controller(vmsettings, ctrller_addr)
def get_attached_disks(self, scsi_controller_path):
volumes = self._conn.query(
self._get_attached_disks_query_string(scsi_controller_path))
return volumes
def _get_attached_disks_query_string(self, scsi_controller_path):
# DVD Drives can be attached to SCSI as well, if the VM Generation is 2
return ("SELECT * FROM Msvm_ResourceAllocationSettingData WHERE ("
"ResourceSubType='%(res_sub_type)s' OR "
"ResourceSubType='%(res_sub_type_virt)s' OR "
"ResourceSubType='%(res_sub_type_dvd)s') AND "
"Parent = '%(parent)s'" % {
'res_sub_type': self._PHYS_DISK_RES_SUB_TYPE,
'res_sub_type_virt': self._DISK_DRIVE_RES_SUB_TYPE,
'res_sub_type_dvd': self._DVD_DRIVE_RES_SUB_TYPE,
'parent': scsi_controller_path.replace("'", "''")})
def _get_new_setting_data(self, class_name):
obj = self._compat_conn.query("SELECT * FROM %s WHERE InstanceID "
"LIKE '%%\\Default'" % class_name)[0]
return obj
def _get_new_resource_setting_data(self, resource_sub_type,
class_name=None):
if class_name is None:
class_name = self._RESOURCE_ALLOC_SETTING_DATA_CLASS
obj = self._compat_conn.query("SELECT * FROM %(class_name)s "
"WHERE ResourceSubType = "
"'%(res_sub_type)s' AND "
"InstanceID LIKE '%%\\Default'" %
{"class_name": class_name,
"res_sub_type": resource_sub_type})[0]
return obj
def attach_scsi_drive(self, vm_name, path, drive_type=constants.DISK):
vmsettings = self._lookup_vm_check(vm_name)
ctrller_path = self._get_vm_scsi_controller(vmsettings)
drive_addr = self.get_free_controller_slot(ctrller_path)
self.attach_drive(vm_name, path, ctrller_path, drive_addr, drive_type)
def attach_ide_drive(self, vm_name, path, ctrller_addr, drive_addr,
drive_type=constants.DISK):
vmsettings = self._lookup_vm_check(vm_name)
ctrller_path = self._get_vm_ide_controller(vmsettings, ctrller_addr)
self.attach_drive(vm_name, path, ctrller_path, drive_addr, drive_type)
def attach_drive(self, vm_name, path, ctrller_path, drive_addr,
drive_type=constants.DISK):
"""Create a drive and attach it to the vm."""
vm = self._lookup_vm_check(vm_name, as_vssd=False)
if drive_type == constants.DISK:
res_sub_type = self._DISK_DRIVE_RES_SUB_TYPE
elif drive_type == constants.DVD:
res_sub_type = self._DVD_DRIVE_RES_SUB_TYPE
drive = self._get_new_resource_setting_data(res_sub_type)
# Set the ctrller as parent.
drive.Parent = ctrller_path
drive.Address = drive_addr
drive.AddressOnParent = drive_addr
# Add the cloned disk drive object to the vm.
new_resources = self._jobutils.add_virt_resource(drive, vm)
drive_path = new_resources[0]
if drive_type == constants.DISK:
res_sub_type = self._HARD_DISK_RES_SUB_TYPE
elif drive_type == constants.DVD:
res_sub_type = self._DVD_DISK_RES_SUB_TYPE
res = self._get_new_resource_setting_data(
res_sub_type, self._STORAGE_ALLOC_SETTING_DATA_CLASS)
res.Parent = drive_path
res.HostResource = [path]
# Add the new vhd object as a virtual hard disk to the vm.
self._jobutils.add_virt_resource(res, vm)
def create_scsi_controller(self, vm_name):
"""Create an iscsi controller ready to mount volumes."""
vmsettings = self._lookup_vm_check(vm_name)
scsicontrl = self._get_new_resource_setting_data(
self._SCSI_CTRL_RES_SUB_TYPE)
scsicontrl.VirtualSystemIdentifiers = ['{' + str(uuid.uuid4()) + '}']
self._jobutils.add_virt_resource(scsicontrl, vmsettings)
def attach_volume_to_controller(self, vm_name, controller_path, address,
mounted_disk_path, serial=None):
"""Attach a volume to a controller."""
vmsettings = self._lookup_vm_check(vm_name)
diskdrive = self._get_new_resource_setting_data(
self._PHYS_DISK_RES_SUB_TYPE)
diskdrive.AddressOnParent = address
diskdrive.Parent = controller_path
diskdrive.HostResource = [mounted_disk_path]
diskdrive_path = self._jobutils.add_virt_resource(diskdrive,
vmsettings)[0]
if serial:
# Apparently this can't be set when the resource is added.
diskdrive = self._get_wmi_obj(diskdrive_path, True)
diskdrive.ElementName = serial
self._jobutils.modify_virt_resource(diskdrive)
def get_vm_physical_disk_mapping(self, vm_name):
mapping = {}
physical_disks = self.get_vm_disks(vm_name)[1]
for diskdrive in physical_disks:
mapping[diskdrive.ElementName] = dict(
resource_path=diskdrive.Path_(),
mounted_disk_path=diskdrive.HostResource[0])
return mapping
def _get_disk_resource_address(self, disk_resource):
return disk_resource.AddressOnParent
def set_disk_host_res(self, disk_res_path, mounted_disk_path):
diskdrive = self._get_wmi_obj(disk_res_path, True)
diskdrive.HostResource = [mounted_disk_path]
self._jobutils.modify_virt_resource(diskdrive)
def set_disk_host_resource(self, vm_name, controller_path, address,
mounted_disk_path):
# TODO(lpetrut): remove this method after the patch fixing
# swapped disks after host reboot merges in Nova.
disk_found = False
vmsettings = self._lookup_vm_check(vm_name)
(disk_resources, volume_resources) = self._get_vm_disks(vmsettings)
for disk_resource in disk_resources + volume_resources:
if (disk_resource.Parent == controller_path and
self._get_disk_resource_address(disk_resource) ==
str(address)):
if (disk_resource.HostResource and
disk_resource.HostResource[0] != mounted_disk_path):
LOG.debug('Updating disk host resource "%(old)s" to '
'"%(new)s"' %
{'old': disk_resource.HostResource[0],
'new': mounted_disk_path})
disk_resource.HostResource = [mounted_disk_path]
self._jobutils.modify_virt_resource(disk_resource)
disk_found = True
break
if not disk_found:
LOG.warning(_LW('Disk not found on controller '
'"%(controller_path)s" with '
'address "%(address)s"'),
{'controller_path': controller_path,
'address': address})
def _get_nic_data_by_name(self, name):
return self._conn.Msvm_SyntheticEthernetPortSettingData(
ElementName=name)[0]
def create_nic(self, vm_name, nic_name, mac_address):
"""Create a (synthetic) nic and attach it to the vm."""
# Create a new nic
new_nic_data = self._get_new_setting_data(
self._SYNTHETIC_ETHERNET_PORT_SETTING_DATA_CLASS)
# Configure the nic
new_nic_data.ElementName = nic_name
new_nic_data.Address = mac_address.replace(':', '')
new_nic_data.StaticMacAddress = 'True'
new_nic_data.VirtualSystemIdentifiers = ['{' + str(uuid.uuid4()) + '}']
# Add the new nic to the vm
vmsettings = self._lookup_vm_check(vm_name)
self._jobutils.add_virt_resource(new_nic_data, vmsettings)
def destroy_nic(self, vm_name, nic_name):
"""Destroys the NIC with the given nic_name from the given VM.
:param vm_name: The name of the VM which has the NIC to be destroyed.
:param nic_name: The NIC's ElementName.
"""
# TODO(claudiub): remove vm_name argument, no longer used.
nic_data = self._get_nic_data_by_name(nic_name)
self._jobutils.remove_virt_resource(nic_data)
def soft_shutdown_vm(self, vm_name):
vm = self._lookup_vm_check(vm_name, as_vssd=False)
shutdown_component = self._conn.Msvm_ShutdownComponent(
SystemName=vm.Name)
if not shutdown_component:
# If no shutdown_component is found, it means the VM is already
# in a shutdown state.
return
reason = 'Soft shutdown requested by OpenStack Nova.'
(ret_val, ) = shutdown_component[0].InitiateShutdown(Force=False,
Reason=reason)
self._jobutils.check_ret_val(ret_val, None)
def set_vm_state(self, vm_name, req_state):
"""Set the desired state of the VM."""
vm = self._lookup_vm_check(vm_name, as_vssd=False)
(job_path,
ret_val) = vm.RequestStateChange(self._vm_power_states_map[req_state])
# Invalid state for current operation (32775) typically means that
# the VM is already in the state requested
self._jobutils.check_ret_val(ret_val, job_path, [0, 32775])
LOG.debug("Successfully changed vm state of %(vm_name)s "
"to %(req_state)s",
{'vm_name': vm_name, 'req_state': req_state})
def _get_disk_resource_disk_path(self, disk_resource):
return disk_resource.HostResource
def get_vm_storage_paths(self, vm_name):
vmsettings = self._lookup_vm_check(vm_name)
(disk_resources, volume_resources) = self._get_vm_disks(vmsettings)
volume_drives = []
for volume_resource in volume_resources:
drive_path = volume_resource.HostResource[0]
volume_drives.append(drive_path)
disk_files = []
for disk_resource in disk_resources:
disk_files.extend(
[c for c in self._get_disk_resource_disk_path(disk_resource)])
return (disk_files, volume_drives)
def get_vm_disks(self, vm_name):
vmsettings = self._lookup_vm_check(vm_name)
return self._get_vm_disks(vmsettings)
def _get_vm_disks(self, vmsettings):
rasds = _wqlutils.get_element_associated_class(
self._compat_conn, self._STORAGE_ALLOC_SETTING_DATA_CLASS,
element_instance_id=vmsettings.InstanceID)
disk_resources = [r for r in rasds if
r.ResourceSubType in
[self._HARD_DISK_RES_SUB_TYPE,
self._DVD_DISK_RES_SUB_TYPE]]
if (self._RESOURCE_ALLOC_SETTING_DATA_CLASS !=
self._STORAGE_ALLOC_SETTING_DATA_CLASS):
rasds = _wqlutils.get_element_associated_class(
self._compat_conn, self._RESOURCE_ALLOC_SETTING_DATA_CLASS,
element_instance_id=vmsettings.InstanceID)
volume_resources = [r for r in rasds if
r.ResourceSubType == self._PHYS_DISK_RES_SUB_TYPE]
return (disk_resources, volume_resources)
def destroy_vm(self, vm_name):
vm = self._lookup_vm_check(vm_name, as_vssd=False)
# Remove the VM. It does not destroy any associated virtual disk.
(job_path, ret_val) = self._vs_man_svc.DestroySystem(vm.path_())
self._jobutils.check_ret_val(ret_val, job_path)
def take_vm_snapshot(self, vm_name):
vm = self._lookup_vm_check(vm_name, as_vssd=False)
vs_snap_svc = self._compat_conn.Msvm_VirtualSystemSnapshotService()[0]
(job_path, snp_setting_data, ret_val) = vs_snap_svc.CreateSnapshot(
AffectedSystem=vm.path_(),
SnapshotType=self._SNAPSHOT_FULL)
self._jobutils.check_ret_val(ret_val, job_path)
vm_path = vm.path_().lower()
current_snapshots = self._conn.Msvm_MostCurrentSnapshotInBranch()
snp_setting_data = [s for s in current_snapshots if
s.Antecedent.path_().lower() == vm_path][0]
return snp_setting_data.Dependent.path_()
def remove_vm_snapshot(self, snapshot_path):
vs_snap_svc = self._compat_conn.Msvm_VirtualSystemSnapshotService()[0]
(job_path, ret_val) = vs_snap_svc.DestroySnapshot(snapshot_path)
self._jobutils.check_ret_val(ret_val, job_path)
def get_vm_dvd_disk_paths(self, vm_name):
vmsettings = self._lookup_vm_check(vm_name)
sasds = _wqlutils.get_element_associated_class(
self._conn, self._STORAGE_ALLOC_SETTING_DATA_CLASS,
element_instance_id=vmsettings.InstanceID)
dvd_paths = [sasd.HostResource[0] for sasd in sasds
if sasd.ResourceSubType == self._DVD_DISK_RES_SUB_TYPE]
return dvd_paths
def is_disk_attached(self, disk_path, is_physical=True):
disk_resource = self._get_mounted_disk_resource_from_path(disk_path,
is_physical)
return disk_resource is not None
def detach_vm_disk(self, vm_name, disk_path, is_physical=True):
# TODO(claudiub): remove vm_name argument, no longer used.
disk_resource = self._get_mounted_disk_resource_from_path(disk_path,
is_physical)
if disk_resource:
parent = self._conn.query("SELECT * FROM "
"Msvm_ResourceAllocationSettingData "
"WHERE __PATH = '%s'" %
disk_resource.Parent)[0]
self._jobutils.remove_virt_resource(disk_resource)
if not is_physical:
self._jobutils.remove_virt_resource(parent)
def _get_mounted_disk_resource_from_path(self, disk_path, is_physical):
if is_physical:
class_name = self._RESOURCE_ALLOC_SETTING_DATA_CLASS
else:
class_name = self._STORAGE_ALLOC_SETTING_DATA_CLASS
query = ("SELECT * FROM %(class_name)s WHERE ("
"ResourceSubType='%(res_sub_type)s' OR "
"ResourceSubType='%(res_sub_type_virt)s' OR "
"ResourceSubType='%(res_sub_type_dvd)s')" % {
'class_name': class_name,
'res_sub_type': self._PHYS_DISK_RES_SUB_TYPE,
'res_sub_type_virt': self._HARD_DISK_RES_SUB_TYPE,
'res_sub_type_dvd': self._DVD_DISK_RES_SUB_TYPE})
disk_resources = self._compat_conn.query(query)
for disk_resource in disk_resources:
if disk_resource.HostResource:
if disk_resource.HostResource[0].lower() == disk_path.lower():
return disk_resource
def get_mounted_disk_by_drive_number(self, device_number):
mounted_disks = self._conn.query("SELECT * FROM Msvm_DiskDrive "
"WHERE DriveNumber=" +
str(device_number))
if len(mounted_disks):
return mounted_disks[0].path_()
def get_controller_volume_paths(self, controller_path):
disks = self._conn.query("SELECT * FROM %(class_name)s "
"WHERE ResourceSubType = '%(res_sub_type)s' "
"AND Parent='%(parent)s'" %
{"class_name":
self._RESOURCE_ALLOC_SETTING_DATA_CLASS,
"res_sub_type":
self._PHYS_DISK_RES_SUB_TYPE,
"parent":
controller_path})
disk_data = {}
for disk in disks:
if disk.HostResource:
disk_data[disk.path().RelPath] = disk.HostResource[0]
return disk_data
def get_free_controller_slot(self, scsi_controller_path):
attached_disks = self.get_attached_disks(scsi_controller_path)
used_slots = [int(disk.AddressOnParent) for disk in attached_disks]
for slot in range(constants.SCSI_CONTROLLER_SLOTS_NUMBER):
if slot not in used_slots:
return slot
raise exceptions.HyperVException(
_("Exceeded the maximum number of slots"))
def get_vm_serial_port_connection(self, vm_name, update_connection=None):
# TODO(lpetrut): Remove this method after the patch implementing
# serial console access support merges in Nova.
vmsettings = self._lookup_vm_check(vm_name)
rasds = _wqlutils.get_element_associated_class(
self._compat_conn, self._SERIAL_PORT_SETTING_DATA_CLASS,
element_instance_id=vmsettings.InstanceID)
serial_port = (
[r for r in rasds if
r.ResourceSubType == self._SERIAL_PORT_RES_SUB_TYPE][0])
if update_connection:
serial_port.Connection = [update_connection]
self._jobutils.modify_virt_resource(serial_port)
if len(serial_port.Connection) > 0:
return serial_port.Connection[0]
def _get_vm_serial_ports(self, vmsettings):
rasds = _wqlutils.get_element_associated_class(
self._compat_conn, self._SERIAL_PORT_SETTING_DATA_CLASS,
element_instance_id=vmsettings.InstanceID)
serial_ports = (
[r for r in rasds if
r.ResourceSubType == self._SERIAL_PORT_RES_SUB_TYPE]
)
return serial_ports
def set_vm_serial_port_connection(self, vm_name, port_number, pipe_path):
vmsettings = self._lookup_vm_check(vm_name)
serial_port = self._get_vm_serial_ports(vmsettings)[port_number - 1]
serial_port.Connection = [pipe_path]
self._jobutils.modify_virt_resource(serial_port)
def get_vm_serial_port_connections(self, vm_name):
vmsettings = self._lookup_vm_check(vm_name)
serial_ports = self._get_vm_serial_ports(vmsettings)
conns = [serial_port.Connection[0]
for serial_port in serial_ports
if serial_port.Connection and serial_port.Connection[0]]
return conns
def get_active_instances(self):
"""Return the names of all the active instances known to Hyper-V."""
vm_names = self.list_instances()
vms = [self._lookup_vm(vm_name, as_vssd=False) for vm_name in vm_names]
active_vm_names = [v.ElementName for v in vms
if v.EnabledState == constants.HYPERV_VM_STATE_ENABLED]
return active_vm_names
def get_vm_power_state_change_listener(
self, timeframe=_DEFAULT_EVENT_CHECK_TIMEFRAME,
event_timeout=_DEFAULT_EVENT_TIMEOUT_MS,
filtered_states=None, get_handler=False):
field = self._VM_ENABLED_STATE_PROP
query = self._get_event_wql_query(cls=self._COMPUTER_SYSTEM_CLASS,
field=field,
timeframe=timeframe,
filtered_states=filtered_states)
listener = self._conn.Msvm_ComputerSystem.watch_for(raw_wql=query,
fields=[field])
def _handle_events(callback):
while True:
try:
# Retrieve one by one all the events that occurred in
# the checked interval.
event = listener(event_timeout)
vm_name = event.ElementName
vm_state = event.EnabledState
vm_power_state = self.get_vm_power_state(vm_state)
try:
callback(vm_name, vm_power_state)
except Exception:
err_msg = _LE("Executing VM power state change event "
"callback failed. "
"VM name: %(vm_name)s, "
"VM power state: %(vm_power_state)s.")
LOG.exception(err_msg,
dict(vm_name=vm_name,
vm_power_state=vm_power_state))
except wmi.x_wmi_timed_out:
pass
except Exception:
LOG.exception(
_LE("The VM power state change event listener "
"encountered an unexpected exception."))
time.sleep(event_timeout / 1000)
return _handle_events if get_handler else listener
def _get_event_wql_query(self, cls, field,
timeframe, filtered_states=None):
"""Return a WQL query used for polling WMI events.
:param cls: the WMI class polled for events
:param field: the field checked
:param timeframe: check for events that occurred in
the specified timeframe
:param filtered_states: only catch events triggered when a WMI
object transitioned into one of those
states.
"""
query = ("SELECT %(field)s, TargetInstance "
"FROM __InstanceModificationEvent "
"WITHIN %(timeframe)s "
"WHERE TargetInstance ISA '%(class)s' "
"AND TargetInstance.%(field)s != "
"PreviousInstance.%(field)s" %
{'class': cls,
'field': field,
'timeframe': timeframe})
if filtered_states:
checks = ["TargetInstance.%s = '%s'" % (field, state)
for state in filtered_states]
query += " AND (%s)" % " OR ".join(checks)
return query
def _get_instance_notes(self, vm_name):
vmsettings = self._lookup_vm_check(vm_name)
return [note for note in vmsettings.Notes if note]
def get_instance_uuid(self, vm_name):
instance_notes = self._get_instance_notes(vm_name)
if instance_notes and uuidutils.is_uuid_like(instance_notes[0]):
return instance_notes[0]
def get_vm_power_state(self, vm_enabled_state):
return self._enabled_states_map.get(vm_enabled_state,
constants.HYPERV_VM_STATE_OTHER)
def get_vm_generation(self, vm_name):
vssd = self._lookup_vm_check(vm_name)
try:
# expected format: 'Microsoft:Hyper-V:SubType:2'
return int(vssd.VirtualSystemSubType.split(':')[-1])
except Exception:
# NOTE(claudiub): The Msvm_VirtualSystemSettingData object does not
# contain the VirtualSystemSubType field on Windows Hyper-V /
# Server 2012.
pass
return constants.VM_GEN_1
def stop_vm_jobs(self, vm_name):
vm = self._lookup_vm_check(vm_name, as_vssd=False)
self._jobutils.stop_jobs(vm)
def enable_secure_boot(self, vm_name, msft_ca_required):
"""Enables Secure Boot for the instance with the given name.
:param vm_name: The name of the VM for which Secure Boot will be
enabled.
:param msft_ca_required: boolean specifying whether the VM will
require Microsoft UEFI Certificate
Authority for Secure Boot. Only Linux
guests require this CA.
"""
vs_data = self._lookup_vm_check(vm_name)
self._set_secure_boot(vs_data, msft_ca_required)
self._modify_virtual_system(vs_data)
def _set_secure_boot(self, vs_data, msft_ca_required):
vs_data.SecureBootEnabled = True
if msft_ca_required:
raise exceptions.HyperVException(
_('UEFI SecureBoot is supported only on Windows instances for '
'this Hyper-V version.'))
def set_disk_qos_specs(self, disk_path, max_iops=None, min_iops=None):
if min_iops is None and max_iops is None:
LOG.debug("Skipping setting disk QoS specs as no "
"value was provided.")
return
disk_resource = self._get_mounted_disk_resource_from_path(
disk_path, is_physical=False)
if max_iops is not None:
disk_resource.IOPSLimit = max_iops
if min_iops is not None:
disk_resource.IOPSReservation = min_iops
self._jobutils.modify_virt_resource(disk_resource)
def _is_drive_physical(self, drive_path):
# TODO(atuvenie): Find better way to check if path represents
# physical or virtual drive.
return not self._pathutils.exists(drive_path)
def _drive_to_boot_source(self, drive_path):
is_physical = self._is_drive_physical(drive_path)
drive = self._get_mounted_disk_resource_from_path(
drive_path, is_physical=is_physical)
rasd_path = drive.path_() if is_physical else drive.Parent
bssd = self._conn.Msvm_LogicalIdentity(
SystemElement=rasd_path)[0].SameElement
return bssd.path_()
def set_boot_order(self, vm_name, device_boot_order):
if self.get_vm_generation(vm_name) == constants.VM_GEN_1:
self._set_boot_order_gen1(vm_name, device_boot_order)
else:
self._set_boot_order_gen2(vm_name, device_boot_order)
def _set_boot_order_gen1(self, vm_name, device_boot_order):
vssd = self._lookup_vm_check(vm_name, for_update=True)
vssd.BootOrder = tuple(device_boot_order)
self._modify_virtual_system(vssd)
def _set_boot_order_gen2(self, vm_name, device_boot_order):
new_boot_order = [(self._drive_to_boot_source(device))
for device in device_boot_order if device]
vssd = self._lookup_vm_check(vm_name)
old_boot_order = vssd.BootSourceOrder
# NOTE(abalutoiu): new_boot_order will contain ROOT uppercase
# in the device paths while old_boot_order will contain root
# lowercase, which will cause the tupple addition result to contain
# each device path twice because of the root lowercase and uppercase.
# Forcing all the device paths to uppercase fixes the issue.
new_boot_order = [x.upper() for x in new_boot_order]
old_boot_order = [x.upper() for x in old_boot_order]
network_boot_devs = set(old_boot_order) ^ set(new_boot_order)
vssd.BootSourceOrder = tuple(new_boot_order) + tuple(network_boot_devs)
self._modify_virtual_system(vssd)
def vm_gen_supports_remotefx(self, vm_gen):
"""RemoteFX is supported only for generation 1 virtual machines
on Windows 8 / Windows Server 2012 and 2012R2.
:returns: True if the given vm_gen is 1, False otherwise
"""
return vm_gen == constants.VM_GEN_1
def _validate_remotefx_params(self, monitor_count, max_resolution,
vram_bytes=None):
max_res_value = self._remote_fx_res_map.get(max_resolution)
if max_res_value is None:
raise exceptions.HyperVRemoteFXException(
_("Unsupported RemoteFX resolution: %s") % max_resolution)
if monitor_count > self._remotefx_max_monitors_map[max_resolution]:
raise exceptions.HyperVRemoteFXException(
_("Unsuported RemoteFX monitor count: %(count)s for "
"this resolution %(res)s. Hyper-V supports a maximum "
"of %(max_monitors)s monitors for this resolution.")
% {'count': monitor_count,
'res': max_resolution,
'max_monitors': self._remotefx_max_monitors_map[
max_resolution]})
def _add_3d_display_controller(self, vm, monitor_count,
max_resolution, vram_bytes=None):
synth_3d_disp_ctrl_res = self._get_new_resource_setting_data(
self._SYNTH_3D_DISP_CTRL_RES_SUB_TYPE,
self._SYNTH_3D_DISP_ALLOCATION_SETTING_DATA_CLASS)
synth_3d_disp_ctrl_res.MaximumMonitors = monitor_count
synth_3d_disp_ctrl_res.MaximumScreenResolution = max_resolution
self._jobutils.add_virt_resource(synth_3d_disp_ctrl_res, vm)
def enable_remotefx_video_adapter(self, vm_name, monitor_count,
max_resolution, vram_bytes=None):
vm = self._lookup_vm_check(vm_name, as_vssd=False)
self._validate_remotefx_params(monitor_count, max_resolution,
vram_bytes=vram_bytes)
rasds = _wqlutils.get_element_associated_class(
self._compat_conn, self._CIM_RES_ALLOC_SETTING_DATA_CLASS,
element_uuid=vm.Name)
if [r for r in rasds if r.ResourceSubType ==
self._SYNTH_3D_DISP_CTRL_RES_SUB_TYPE]:
raise exceptions.HyperVRemoteFXException(
_("RemoteFX is already configured for this VM"))
synth_disp_ctrl_res_list = [r for r in rasds if r.ResourceSubType ==
self._SYNTH_DISP_CTRL_RES_SUB_TYPE]
if synth_disp_ctrl_res_list:
self._jobutils.remove_virt_resource(synth_disp_ctrl_res_list[0])
max_res_value = self._remote_fx_res_map.get(max_resolution)
self._add_3d_display_controller(vm, monitor_count, max_res_value,
vram_bytes)
if self._vm_has_s3_controller(vm.ElementName):
s3_disp_ctrl_res = [r for r in rasds if r.ResourceSubType ==
self._S3_DISP_CTRL_RES_SUB_TYPE][0]
s3_disp_ctrl_res.Address = self._DISP_CTRL_ADDRESS_DX_11
self._jobutils.modify_virt_resource(s3_disp_ctrl_res)
def _vm_has_s3_controller(self, vm_name):
return True
|