1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 | <?xml version="1.0"?>
<!--
use "man thermal-conf.xml" for details
-->
<!-- BEGIN -->
<ThermalConfiguration>
<Platform>
<Name>Generic X86 Laptop Device</Name>
<ProductName>EXAMPLE_SYSTEM</ProductName>
<Preference>QUIET</Preference>
<ThermalSensors>
<ThermalSensor>
<Type>TSKN</Type>
<AsyncCapable>1</AsyncCapable>
</ThermalSensor>
</ThermalSensors>
<ThermalZones>
<ThermalZone>
<Type>SKIN</Type>
<TripPoints>
<TripPoint>
<SensorType>TSKN</SensorType>
<Temperature>55000</Temperature>
<type>passive</type>
<ControlType>SEQUENTIAL</ControlType>
<CoolingDevice>
<index>1</index>
<type>rapl_controller</type>
<influence> 100 </influence>
<SamplingPeriod> 16 </SamplingPeriod>
</CoolingDevice>
<CoolingDevice>
<index>2</index>
<type>intel_powerclamp</type>
<influence> 100 </influence>
<SamplingPeriod> 12 </SamplingPeriod>
</CoolingDevice>
</TripPoint>
</TripPoints>
</ThermalZone>
</ThermalZones>
</Platform>
<!-- Thermal configuration example only -->
<Platform>
<Name>Example Platform Name</Name>
<!--UUID is optional, if present this will be matched -->
<!-- Both product name and UUID can contain
wild card "*", which matches any platform
-->
<UUID>Example UUID</UUID>
<ProductName>Example Product Name</ProductName>
<Preference>QUIET</Preference>
<ThermalSensors>
<ThermalSensor>
<!-- New Sensor with a type and path -->
<Type>example_sensor_1</Type>
<Path>/some_path</Path>
<AsyncCapable>0</AsyncCapable>
</ThermalSensor>
<ThermalSensor>
<!-- Already present in thermal sysfs,
enable this or add/change config
For example, here we are indicating that
sensor can do async events to avoid polling
-->
<Type>example_thermal_sysfs_sensor</Type>
<!-- If async capable, then we don't need to poll -->
<AsyncCapable>1</AsyncCapable>
</ThermalSensor>
<ThermalSensor>
<!-- Examle of a virtual sensor. This sensor
depends on other real sensor or
virtual sensor.
E.g. here the temp will be
temp of example_sensor_1 * 0.5 + 10
-->
<Type>example_virtual_sensor</Type>
<Virtual>1</Virtual>
<SensorLink>
<SensorType>example_sensor_1</SensorType>
<Multiplier> 0.5 </Multiplier>
<Offset> 10 </Offset>
</SensorLink>
</ThermalSensor>
</ThermalSensors>
<ThermalZones>
<ThermalZone>
<Type>Example Zone type</Type>
<TripPoints>
<TripPoint>
<SensorType>example_sensor_1</SensorType>
<!-- Temperature at which to take action -->
<Temperature> 75000 </Temperature>
<!-- max/passive/active
If a MAX type is specified, then
daemon will use PID control
to aggresively throttle to avoid
reaching this temp.
-->
<type>max</type>
<!-- SEQUENTIAL | PARALLEL
When a trip point temp is violated, then
number of cooling device can be activated.
If control type is SEQUENTIAL then
It will exhaust first cooling device before trying
next.
-->
<ControlType>SEQUENTIAL</ControlType>
<CoolingDevice>
<index>1</index>
<type>example_cooling_device</type>
<!-- Influence will be used order cooling devices.
First cooling device will be used, which has
highest influence.
-->
<influence> 100 </influence>
<!-- Delay in using this cdev, this takes some time
too actually cool a zone
-->
<SamplingPeriod> 12 </SamplingPeriod>
</CoolingDevice>
</TripPoint>
</TripPoints>
</ThermalZone>
</ThermalZones>
<CoolingDevices>
<CoolingDevice>
<!--
Cooling device can be specified
by a type and optionally a sysfs path
If the type already present in thermal sysfs
no need of a path.
Compensation can use min/max and step size
to increasing cool the system.
Debounce period can be used to force
a waiting period for action
-->
<Type>example_cooling_device</Type>
<MinState>0</MinState>
<IncDecStep>10</IncDecStep>
<ReadBack> 0 </ReadBack>
<MaxState>50</MaxState>
<DebouncePeriod>5000</DebouncePeriod>
<!--
If there are no PID parameter
compensation increase step wise and exponentaially
if single step is not able to change trend.
Alternatively a PID parameters can be specified
then next step will use PID calculation using
provided PID constants.
-->>
<PidControl>
<kp>0.001</kp>
<kd>0.0001</kd>
<ki>0.0001</ki>
</PidControl>
</CoolingDevice>
</CoolingDevices>
</Platform>
</ThermalConfiguration>
<!-- END -->
|