/usr/share/nsis/Include/VB6RunTime.nsh is in nsis-common 2.50-1.
This file is owned by root:root, with mode 0o644.
The actual contents of the file can be viewed below.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 | /*
VB6RunTime.nsh
Setup of Visual Basic 6.0 run-time files, including the Oleaut32.dll security update
Copyright 2008-2015 Joost Verburg
To obtain the run-time files, download and extract
http://nsis.sourceforge.net/vb6runtime.zip
Script code for installation:
!insertmacro InstallVB6RunTime FOLDER ALREADY_INSTALLED
in which FOLDER is the location of the run-time files and ALREADY_INSTALLED is the
name of a variable that is empty when the application is installed for the first time
and non-empty otherwise
Script code for uninstallation:
!insertmacro UnInstallVB6RunTime
Remarks:
* You may have to install additional files for such Visual Basic application to work,
such as OCX files for user interface controls.
* Installation of the run-time files requires Administrator or Power User privileges.
Use the Multi-User header file to verify whether these privileges are available.
* Add a Modern UI finish page or another check (see IfRebootFlag in the NSIS Users
Manual) to allow the user to restart the computer when necessary.
*/
!ifndef VB6_INCLUDED
!define VB6_INCLUDED
!verbose push
!verbose 3
!include Library.nsh
!include WinVer.nsh
!macro VB6RunTimeInstall FOLDER ALREADY_INSTALLED
!insertmacro InstallLib REGDLL "${ALREADY_INSTALLED}" REBOOT_PROTECTED "${FOLDER}\msvbvm60.dll" "$SYSDIR\msvbvm60.dll" "$SYSDIR"
;The files below will only be installed on Win9x/NT4
!insertmacro InstallLib REGDLL "${ALREADY_INSTALLED}" REBOOT_PROTECTED "${FOLDER}\olepro32.dll" "$SYSDIR\olepro32.dll" "$SYSDIR"
!insertmacro InstallLib REGDLL "${ALREADY_INSTALLED}" REBOOT_PROTECTED "${FOLDER}\comcat.dll" "$SYSDIR\comcat.dll" "$SYSDIR"
!insertmacro InstallLib DLL "${ALREADY_INSTALLED}" REBOOT_PROTECTED "${FOLDER}\asycfilt.dll" "$SYSDIR\asycfilt.dll" "$SYSDIR"
!insertmacro InstallLib TLB "${ALREADY_INSTALLED}" REBOOT_PROTECTED "${FOLDER}\stdole2.tlb" "$SYSDIR\stdole2.tlb" "$SYSDIR"
Push $R0
${if} ${IsNT}
${if} ${IsWinNT4}
ReadRegStr $R0 HKLM "System\CurrentControlSet\Control" "ProductOptions"
${if} $R0 == "Terminal Server"
!insertmacro InstallLib REGDLL "${ALREADY_INSTALLED}" REBOOT_NOTPROTECTED "${FOLDER}\NT4TS\oleaut32.dll" "$SYSDIR\oleaut32.dll" "$SYSDIR"
${else}
!insertmacro InstallLib REGDLL "${ALREADY_INSTALLED}" REBOOT_NOTPROTECTED "${FOLDER}\NT4\oleaut32.dll" "$SYSDIR\oleaut32.dll" "$SYSDIR"
${endif}
${endif}
${else}
;No Oleaut32.dll with the security update has been released for Windows 9x.
;The NT4 version is used because NT4 and Win9x used to share the same 2.40 version
;and version 2.40.4519.0 is reported to work fine on Win9x.
!insertmacro InstallLib REGDLL "${ALREADY_INSTALLED}" REBOOT_NOTPROTECTED "${FOLDER}\NT4\oleaut32.dll" "$SYSDIR\oleaut32.dll" "$SYSDIR"
${endif}
Pop $R0
!macroend
!macro VB6RunTimeUnInstall
!insertmacro UnInstallLib REGDLL SHARED NOREMOVE "$SYSDIR\msvbvm60.dll"
!insertmacro UnInstallLib REGDLL SHARED NOREMOVE "$SYSDIR\oleaut32.dll"
!insertmacro UnInstallLib REGDLL SHARED NOREMOVE "$SYSDIR\olepro32.dll"
!insertmacro UnInstallLib REGDLL SHARED NOREMOVE "$SYSDIR\comcat.dll"
!insertmacro UnInstallLib DLL SHARED NOREMOVE "$SYSDIR\asycfilt.dll"
!insertmacro UnInstallLib TLB SHARED NOREMOVE "$SYSDIR\stdole2.tlb"
!macroend
!verbose pop
!endif
|