1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 | """
=============================================
SNR estimation for Diffusion-Weighted Images
=============================================
Computing the Signal-to-Noise-Ratio (SNR) of DW images is still an open question,
as SNR depends on the white matter structure of interest as well as
the gradient direction corresponding to each DWI.
In classical MRI, SNR can be defined as the ratio of the mean
of the signal divided by the standard deviation of the
underlying Gaussian noise, that is SNR = mean(signal) / std(noise).
The noise standard deviation can be
computed from the background in any of the DW images. How do we compute
the mean of the signal, and what signal?
The strategy here is to compute a 'worst-case' SNR for DWI. Several white matter
structures such as the corpus callosum (CC), corticospinal tract (CST), or
the superior longitudinal fasciculus (SLF) can be easily identified from
the colored-FA (cfa) map. In this example, we will use voxels from the CC,
which have the characteristic of being highly RED in the cfa map since they are mainly oriented in
the left-right direction. We know that the DW image
closest to the x-direction will be the one with the most attenuated diffusion signal.
This is the strategy adopted in several recent papers (see [1]_ and [2]_). It gives a good
indication of the quality of the DWI data.
First, we compute the tensor model in a brain mask (see the DTI example for more explanation).
"""
from __future__ import division, print_function
import nibabel as nib
import numpy as np
from dipy.data import fetch_stanford_hardi, read_stanford_hardi
from dipy.segment.mask import median_otsu
from dipy.reconst.dti import TensorModel
fetch_stanford_hardi()
img, gtab = read_stanford_hardi()
data = img.get_data()
affine = img.get_affine()
print('Computing brain mask...')
b0_mask, mask = median_otsu(data)
print('Computing tensors...')
tenmodel = TensorModel(gtab)
tensorfit = tenmodel.fit(data, mask=mask)
"""Next, we set our red-green-blue thresholds to (0.6, 1) in the x axis
and (0, 0.1) in the y and z axes respectively.
These values work well in practice to isolate the very RED voxels of the cfa map.
Then, as assurance, we want just RED voxels in the CC (there could be
noisy red voxels around the brain mask and we don't want those). Unless the brain
acquisition was badly aligned, the CC is always close to the mid-sagittal slice.
The following lines perform these two operations and then saves the computed mask.
"""
print('Computing worst-case/best-case SNR using the corpus callosum...')
from dipy.segment.mask import segment_from_cfa
from dipy.segment.mask import bounding_box
threshold = (0.6, 1, 0, 0.1, 0, 0.1)
CC_box = np.zeros_like(data[..., 0])
mins, maxs = bounding_box(mask)
mins = np.array(mins)
maxs = np.array(maxs)
diff = (maxs - mins) // 4
bounds_min = mins + diff
bounds_max = maxs - diff
CC_box[bounds_min[0]:bounds_max[0],
bounds_min[1]:bounds_max[1],
bounds_min[2]:bounds_max[2]] = 1
mask_cc_part, cfa = segment_from_cfa(tensorfit, CC_box,
threshold, return_cfa=True)
cfa_img = nib.Nifti1Image((cfa*255).astype(np.uint8), affine)
mask_cc_part_img = nib.Nifti1Image(mask_cc_part.astype(np.uint8), affine)
nib.save(mask_cc_part_img, 'mask_CC_part.nii.gz')
import matplotlib.pyplot as plt
region = 40
fig = plt.figure('Corpus callosum segmentation')
plt.subplot(1, 2, 1)
plt.title("Corpus callosum (CC)")
plt.axis('off')
red = cfa[..., 0]
plt.imshow(np.rot90(red[region, ...]))
plt.subplot(1, 2, 2)
plt.title("CC mask used for SNR computation")
plt.axis('off')
plt.imshow(np.rot90(mask_cc_part[region, ...]))
fig.savefig("CC_segmentation.png", bbox_inches='tight')
"""
.. figure:: CC_segmentation.png
:align: center
"""
"""Now that we are happy with our crude CC mask that selected voxels in the x-direction,
we can use all the voxels to estimate the mean signal in this region.
"""
mean_signal = np.mean(data[mask_cc_part], axis=0)
"""Now, we need a good background estimation. We will re-use the brain mask
computed before and invert it to catch the outside of the brain. This could
also be determined manually with a ROI in the background.
[Warning: Certain MR manufacturers mask out the outside of the brain with 0's.
One thus has to be careful how the noise ROI is defined].
"""
from scipy.ndimage.morphology import binary_dilation
mask_noise = binary_dilation(mask, iterations=10)
mask_noise[..., :mask_noise.shape[-1]//2] = 1
mask_noise = ~mask_noise
mask_noise_img = nib.Nifti1Image(mask_noise.astype(np.uint8), affine)
nib.save(mask_noise_img, 'mask_noise.nii.gz')
noise_std = np.std(data[mask_noise, :])
print('Noise standard deviation sigma= ', noise_std)
"""We can now compute the SNR for each DWI. For example, report SNR
for DW images with gradient direction that lies the closest to
the X, Y and Z axes.
"""
# Exclude null bvecs from the search
idx = np.sum(gtab.bvecs, axis=-1) == 0
gtab.bvecs[idx] = np.inf
axis_X = np.argmin(np.sum((gtab.bvecs-np.array([1, 0, 0]))**2, axis=-1))
axis_Y = np.argmin(np.sum((gtab.bvecs-np.array([0, 1, 0]))**2, axis=-1))
axis_Z = np.argmin(np.sum((gtab.bvecs-np.array([0, 0, 1]))**2, axis=-1))
for direction in [0, axis_X, axis_Y, axis_Z]:
SNR = mean_signal[direction]/noise_std
if direction == 0 :
print("SNR for the b=0 image is :", SNR)
else :
print("SNR for direction", direction, " ", gtab.bvecs[direction], "is :", SNR)
"""SNR for the b=0 image is : ''42.0695455758''"""
"""SNR for direction 58 [ 0.98875 0.1177 -0.09229] is : ''5.46995373635''"""
"""SNR for direction 57 [-0.05039 0.99871 0.0054406] is : ''23.9329492871''"""
"""SNR for direction 126 [-0.11825 -0.039925 0.99218 ] is : ''23.9965694823''"""
"""
Since the CC is aligned with the X axis, the lowest SNR is for that gradient
direction. In comparison, the DW images in
the perpendical Y and Z axes have a high SNR. The b0 still exhibits the highest SNR,
since there is no signal attenuation.
Hence, we can say the Stanford diffusion
data has a 'worst-case' SNR of approximately 5, a
'best-case' SNR of approximately 24, and a SNR of 42 on the b0 image.
"""
"""
References:
.. [1] Descoteaux, M., Deriche, R., Le Bihan, D., Mangin, J.-F., and Poupon, C.
Multiple q-shell diffusion propagator imaging.
Medical image analysis, 15(4), 603, 2011.
.. [2] Jones, D. K., Knosche, T. R., & Turner, R.
White Matter Integrity, Fiber Count, and Other Fallacies: The Dos and Don'ts of Diffusion MRI.
NeuroImage, 73, 239, 2013.
"""
|