/usr/include/trilinos/MueLu_VerbosityLevel.hpp is in libtrilinos-muelu-dev 12.4.2-2.
This file is owned by root:root, with mode 0o644.
The actual contents of the file can be viewed below.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 | // @HEADER
//
// ***********************************************************************
//
// MueLu: A package for multigrid based preconditioning
// Copyright 2012 Sandia Corporation
//
// Under the terms of Contract DE-AC04-94AL85000 with Sandia Corporation,
// the U.S. Government retains certain rights in this software.
//
// Redistribution and use in source and binary forms, with or without
// modification, are permitted provided that the following conditions are
// met:
//
// 1. Redistributions of source code must retain the above copyright
// notice, this list of conditions and the following disclaimer.
//
// 2. Redistributions in binary form must reproduce the above copyright
// notice, this list of conditions and the following disclaimer in the
// documentation and/or other materials provided with the distribution.
//
// 3. Neither the name of the Corporation nor the names of the
// contributors may be used to endorse or promote products derived from
// this software without specific prior written permission.
//
// THIS SOFTWARE IS PROVIDED BY SANDIA CORPORATION "AS IS" AND ANY
// EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
// IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
// PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL SANDIA CORPORATION OR THE
// CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL,
// EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO,
// PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR
// PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF
// LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING
// NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS
// SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
//
// Questions? Contact
// Jonathan Hu (jhu@sandia.gov)
// Andrey Prokopenko (aprokop@sandia.gov)
// Ray Tuminaro (rstumin@sandia.gov)
//
// ***********************************************************************
//
// @HEADER
#ifndef MUELU_VERBOSITYLEVEL_HPP
#define MUELU_VERBOSITYLEVEL_HPP
#include <Teuchos_VerbosityLevel.hpp>
namespace MueLu {
enum MsgType
{
Errors = 0x00000001, //!< Errors
Warnings0 = 0x00000010, //!< Important warning messages (one line)
Warnings00 = 0x00000020, //!< Important warning messages (more verbose)
Warnings1 = 0x00000040, //!< Additional warnings
PerfWarnings = 0x00000080, //!< Performance warnings
Runtime0 = 0x00000100, //!< One-liner description of what is happening
Runtime1 = 0x00000200, //!< Description of what is happening (more verbose)
RuntimeTimings = 0x00000400, //!< Timers that are enabled (using Timings0/Timings1) will be printed during the execution
NoTimeReport = 0x00000800, //!< By default, enabled timers appears in the teuchos time monitor summary. Use this option if you do not want to record timing information.
Parameters0 = 0x00001000, //!< Print class parameters
Parameters1 = 0x00002000, //!< Print class parameters (more parameters, more verbose)
Statistics0 = 0x00010000, //!< Print statistics that do not involve significant additional computation
Statistics1 = 0x00020000, //!< Print more statistics
Statistics2 = 0x00040000, //!< Print even more statistics
Timings0 = 0x00100000, //!< High level timing information (use Teuchos::TimeMonitor::summarize() to print)
Timings1 = 0x00200000, //!< Detailed timing information (use Teuchos::TimeMonitor::summarize() to print)
TimingsByLevel = 0x00400000, //!< Record timing information level by level. Must be used in combinaison with Timings0/Timings1
External = 0x01000000, //!< Print external lib objects
Debug = 0x02000000, //!< Print additional debugging information
Test = 0x10000000, //!< Print skeleton for the run, i.e. factory calls and used parameters
// Predefined combinations of MsgType
// Can be used in user code or examples. Do not used as input parameters of IsPrint() or GetOStream().
Warnings = Warnings0 | Warnings00 | Warnings1 | PerfWarnings, //!< Print all warning messages
Runtime = Runtime0 | Runtime1, //!< Print description of what is going on
Parameters = Parameters0 | Parameters1, //!< Print parameters
Statistics = Statistics0 | Statistics1 | Statistics2, //!< Print all statistics
Timings = Timings0 | Timings1 | TimingsByLevel, //!< Print all timing information
//
None = 0,
Low = Errors | Warnings0 | Runtime0 | Parameters0 | Statistics0 | Timings0,
Medium = Errors | Warnings0 | Runtime0 | Parameters0 | Statistics0 | Statistics1 | Timings0,
High = Errors | Warnings | Runtime | Parameters | Statistics | Timings,
#ifdef HAVE_MUELU_DEBUG
Extreme = Errors | Warnings | Runtime | Parameters | Statistics | Timings | External | Debug,
#else
Extreme = Errors | Warnings | Runtime | Parameters | Statistics | Timings | External,
#endif
Default = High, // This is the default of print() methods. For VerboseObject, another default is set by VerboseObject::globalVerbLevel_ // TODO: move it to the VerboseObject class
NotSpecified = -1
};
//!
typedef int VerbLevel;
//!
VerbLevel toMueLuVerbLevel(const Teuchos::EVerbosityLevel verbLevel);
} // namespace MueLu
#endif
|